(Translated by https://www.hiragana.jp/)
Fil:Heatpump.svg - Wikipedia, den frie encyklopædi Spring til indhold

Fil:Heatpump.svg

Sidens indhold er ikke tilgængeligt på andre sprog.
Fra Wikipedia, den frie encyklopædi

Fuld opløsning (SVG fil, basisstørrelse 750 × 438 pixels, filstørrelse: 34 KB)


Denne fil er fra Wikimedia Commons

Beskrivelse

Beskrivelse
English: Diagram of a phase change heat pump.
Note that the arrows in the diagram are meant to indicate the flow of air and coolant; they do not correspond to heat flow, which in the system depicted is (generally) from right to left.
Deutsch: Schema einer Wärmepumpe mit Phasenwechsel.
Kilde Eget arbejde
Forfatter Ilmari Karonen
SVG udvikling
InfoField
 
The SVG code is valid.
 
Vektorgrafikken blev lavet med Inkscape. .
 
This diagram uses embedded text/digits.

Legend

  1. Condenser coil (hot side heat exchanger, gas cools and liquifies)
  2. Metering Device (liquid expands and cools)
  3. Evaporator coil (cold side heat exchanger, liquid vaporizes and heats up)
  4. Compressor (gas is compressed and heats up)
Red = Gas at high pressure and very high temperature
Pink = Liquid at high pressure and high temperature
Blue = Liquid at low pressure and very low temperature
Light Blue = Gas at low pressure and low temperature

Licensering

Public domain Jeg, indehaveren af ophavsretten til dette værk, udgiver dette værk som offentlig ejendom. Dette gælder i hele verden.
I nogle lande er dette ikke juridisk muligt. I så fald:
Jeg giver enhver ret til at anvende dette værk til ethvert formål, uden nogen restriktioner, medmindre sådanne restriktioner er påkrævede ved lov.

Captions

Tilføj en kort forklaring på en enkelt linje om hvad filen viser

Elementer som er med i denne fil

afbilder

Filhistorik

Klik på en dato/tid for at se filen som den så ud på det tidspunkt.

(Nyeste | Ældste) Se (10 nyere | ) (10 | 20 | 50 | 100 | 250 | 500)
Dato/tidMiniaturebilledeDimensionerBrugerKommentar
nuværende5. apr. 2017, 10:22Miniature af versionen fra 5. apr. 2017, 10:22750 × 438 (34 KB)Jahobrcleanup, I hope errors are fixed
13. dec. 2007, 09:20Miniature af versionen fra 13. dec. 2007, 09:20750 × 438 (63 KB)No-w-ayReverted to version as of 20:49, 12 December 2005
12. dec. 2007, 17:07Miniature af versionen fra 12. dec. 2007, 17:07750 × 438 (51 KB)No-w-ayReverted to version as of 20:27, 12 December 2005
12. dec. 2007, 17:06Miniature af versionen fra 12. dec. 2007, 17:06715 × 367 (88 KB)No-w-ayNew version with the arrow in the evaporator coil reversed to show correctly the heat transfer (from outside environment to the inside fluid).
12. dec. 2007, 17:03Miniature af versionen fra 12. dec. 2007, 17:03715 × 367 (88 KB)No-w-ayDiagram of a phase change heat pump. Drawn in Inkscape by Ilmari Karonen. New version with the arrow in the evaporator coil reversed to show correctly the heat transfer (from outside environment to the inside fluid).
12. dec. 2005, 21:49Miniature af versionen fra 12. dec. 2005, 21:49750 × 438 (63 KB)Ilmari Karonenso close...
12. dec. 2005, 21:46Miniature af versionen fra 12. dec. 2005, 21:46750 × 438 (62 KB)Ilmari Karonenkeep trying
12. dec. 2005, 21:42Miniature af versionen fra 12. dec. 2005, 21:42750 × 438 (50 KB)Ilmari Karonensigh...
12. dec. 2005, 21:38Miniature af versionen fra 12. dec. 2005, 21:38750 × 438 (50 KB)Ilmari Karonengoddammit!
12. dec. 2005, 21:35Miniature af versionen fra 12. dec. 2005, 21:35750 × 438 (50 KB)Ilmari Karonendamnit, why can't these things render consistently?
(Nyeste | Ældste) Se (10 nyere | ) (10 | 20 | 50 | 100 | 250 | 500)

Den følgende side bruger denne fil:

Global filanvendelse

Følgende andre wikier anvender denne fil:

Vis flere globale anvendelser af denne fil.

Metadata