Thin sections: I. A study of section thickness and physical distortion produced during microtomy

LD Peachey - The Journal of Cell Biology, 1958 - rupress.org
… between specimen thickness and the resolution attainable in the … thinner the specimen, the
better is the attainable resolution. … image densities are shown for different parts of the image. …

EELS log‐ratio technique for specimenthickness measurement in the TEM

T Malis, SC Cheng, RF Egerton - Journal of electron …, 1988 - Wiley Online Library
Specimen thickness can furnish an estimate of beam broadening which is important in
determining the spatial resolution of … defect densities from TEM images has always been present. …

[HTML][HTML] Algorithms for scanned probe microscope image simulation, surface reconstruction, and tip estimation

JS Villarrubia - Journal of research of the National Institute of …, 1997 - ncbi.nlm.nih.gov
… They provide three-dimensional images with resolution at or … The specimen surface is the
thick continuous line. The … to reconstruct the specimen surface from its image. In general, the …

Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens

J Miao, P Charalambous, J Kirz, D Sayre - Nature, 1999 - nature.com
… in specimens too thick for electron microscopy, the highest-resolution applications of X-ray
imaging … We believe that resolutions of 10–20 nm should be achievable; this would provide an …

Orthogonal‐plane fluorescence optical sectioning: Three‐dimensional imaging of macroscopic biological specimens

AH Voie, DH Burns, FA Spelman - Journal of microscopy, 1993 - Wiley Online Library
specimen. Optical sectioning is the process of moving a thick specimen through the focal plane
of an imaging … Consequently, the axial resolution of the image is equal to the thickness of …

High strain rate characterisation of unidirectional carbon-epoxy IM7-8552 in transverse compression and in-plane shear using digital image correlation

H Koerber, J Xavier, PP Camanho - Mechanics of Materials, 2010 - Elsevier
specimens whereas a slightly coarser pattern was used for the dynamic specimens,
considering the different image resolutions of … is slightly inclined with regard to the through-thickness

Effects of layer thickness and binder saturation level parameters on 3D printing process

M Vaezi, CK Chua - The International Journal of Advanced Manufacturing …, 2011 - Springer
specimens and individual network structure specimens are made by the 3D printing process
under different layer thicknesses … uses inkjet print heads with a resolution of 600 dots per …

A test object and criteria for high resolution electron microscopy

RD Heidenreich, WM Hess, LL Ban - Journal of Applied …, 1968 - scripts.iucr.org
… for evaluating image performance of any specimen yet suggested. … specimens which are
much thinner than the mean free path for scattering. For intelligible images the object thickness

A three-dimensional digital image correlation technique for strain measurements in microstructures

E Verhulp, B van Rietbergen, R Huiskes - Journal of biomechanics, 2004 - Elsevier
… density of 0.07 and mean trabecular thickness of 0.3 mm, were … Since both images were
obtained for the same specimen … The influence of image resolution on the standard deviation in …

Electron microscopy of specimens in liquid

N De Jonge, FM Ross - Nature nanotechnology, 2011 - nature.com
… consider the resolution expected for imaging in liquids, … TEM image of a 1-μみゅーm-thick sample
with 20 nm resolution would … permitted STEM imaging of yeast cells with a resolution 49 of …