Iron Removal
Iron and manganese are unaesthetic parameters present mostly in groundwater, causing unwanted precipitation and color. | |||||||||||
Iron removal Iron removal is based on the precipitation of dissolved iron (Fe2+) into its oxidized form (Fe3+), as Fe(OH)3 or Fe2O3.Iron removal by physical-chemical way consists in iron oxidation by air followed by sand filtration, but other techniques exist as well:
Oxidation can be carried out by various chemicals like chlorine, ozone but is mostly done by compressed air. Complex bound iron and manganese, e.g. complex bound with humic acids, can be very difficult to remove. In this case oxidation with ozone can be a solution. Manganese removal For manganese removal only, Manganese dioxide (MnO2) is used as an adsorbent according to the following reaction: Mn + MnO2 (s) --> 2 MnO (s) Manganese oxides are then adsorbed on MnO2 grains. When all MnO2 has been consumed, it can be regenerated by sodium hypochlorite. Manganese removal by physical-chemical way (aeration and sand filtration) can also be used but manganese oxidation kinetics are too slow at pH< 9. Check our iron removal plants |
About Lenntech
Lenntech BV
Rotterdamseweg 402 M
2629 HH Delft
tel: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com