Comparative characterization study of LYSO:Ce crystals for timing applications
Authors:
F. M. Addesa,
P. Barria,
R. Bianco,
M. Campana,
F. Cavallari,
A. Cemmi,
M. Cipriani,
I. Dafinei,
B. ď Orsi,
D. del Re,
M. Diemoz,
G. ď Imperio,
E. Di Marco,
I. Di Sarcina,
M. Enculescu,
E. Longo,
M. T. Lucchini,
F. Marchegiani,
P. Meridiani,
S. Nisi,
G. Organtini,
F. Pandolfi,
R. Paramatti,
V. Pettinacci,
C. Quaranta
, et al. (6 additional authors not shown)
Abstract:
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce (…
▽ More
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce ($[Lu_{(1-x)}Y_x]_2SiO_5$:$Ce$) crystals is presented. It involves for the first time a large number of crystal samples (180) of the same size from a dozen of producers.The study consists of a comparative characterization of LYSO:Ce crystal products available on the market by mechanical, optical and scintillation measurements and aims specifically, to investigate key parameters of timing applications for HEP.
△ Less
Submitted 3 June, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Multiple scattering of channeled and non-channeled positively charged particles in bent monocrystalline silicon
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
R. Losito,
A. Masi,
D. Mirarchi,
S. Montesano,
S. Redaelli,
R. Rossi,
G. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
L. Bandiera,
V. Guidi,
A. Mazzolari,
M. Romagnoni,
F. Murtas,
F. Addesa,
G. Cavoto,
F. Iacoangeli
, et al. (17 additional authors not shown)
Abstract:
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in d…
▽ More
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in detail the influence of angular constraints on the magnitude of the effect. Comparison of the multiple scattering process at different energies indicates a violation of the law of inverse proportionality of the rms angle of channeled particles with energy. By increasing the statistics, we have improved the results of multiple scattering measurements for particles moving, but not channeled, in silicon crystals.
△ Less
Submitted 31 January, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Double-crystal measurements at the CERN SPS
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
M. D'Andrea,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
D. Mirarchi,
S. Montesano,
A. Natochii,
S. Redaelli,
R. Rossi,
G. I. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
F. Addesa,
F. Murtas,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov
, et al. (13 additional authors not shown)
Abstract:
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam confi…
▽ More
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam configuration. Timepix detectors and high-sensitivity Beam Loss Monitors were exploited to observe the deflected beams. Linear and angular scans allowed exploring the particle interactions with the two crystals and recording their efficiency. The measured values of the beam trajectories, profiles and of the channeling efficiency agree with the results of a Monte-Carlo simulation.
△ Less
Submitted 26 March, 2021;
originally announced March 2021.
-
Reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals
Authors:
W. Scandale,
L. S. Esposito,
M. Garattini,
R. Rossi,
V. Zhovkovska,
A. Natochii,
F. Addesa,
F. Iacoangeli,
F. Galluccio,
F. Murtas,
A. G. Afonin,
Yu. A. Chesnokov,
A. A. Durum,
V. A. Maisheev,
Yu. E. Sandomirskiy,
A. A. Yanovich,
G. I. Smirnov,
Yu. A. Gavrikov,
Yu. M. Ivanov,
M. A. Koznov,
M. V. Malkov,
L. G. Malyarenko,
I. G. Mamunct,
J. Borg,
T. James
, et al. (2 additional authors not shown)
Abstract:
We present the experimental observation of the reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals. According to our measurements the rms angle of multiple scattering in the plane orthogonal to the plane of the channeling is less than half that for non-channeled particles moving in the same crystal. In the experiment we use focusing ben…
▽ More
We present the experimental observation of the reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals. According to our measurements the rms angle of multiple scattering in the plane orthogonal to the plane of the channeling is less than half that for non-channeled particles moving in the same crystal. In the experiment we use focusing bent single crystals. Such crystals have a variable thickness in the direction of beam propagation. This allows us to measure rms angles of scattering as a function of thickness for channeled and non-channeled particles. The behaviour with thickness of non-channeled particles is in agreement with expectations whereas the behaviour of channeled particles has unexpected features. We give a semi-quantitative explanation of the observed effect.
△ Less
Submitted 1 October, 2019;
originally announced October 2019.
-
Double-crystal setup measurements at the CERN SPS
Authors:
W. Scandale,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
S. Montesano,
R. Rossi,
L. Burmistrov,
S. Dubos,
A. Natochii,
V. Puill,
A. Stocchi,
V. Zhovkovska,
F. Murtas,
F. Addesa,
F. Iacoangeli,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
G. I. Smirnov,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov,
L. P. Lapina,
L. G. Malyarenko
, et al. (11 additional authors not shown)
Abstract:
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadro…
▽ More
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadron Collider (LHC) scale. The presented in the text configuration was used for the quantitative characterization of the deflected particle beam by a pair of bent silicon crystals. For the first time in the double-crystal configuration, a particle deflection efficiency by the second crystal of $0.188 \pm 3 \cdot 10^{-5}$ and $0.179 \pm 0.013$ was measured on the accelerator by means of the Timepix detector and Beam Loss Monitor (BLM) respectively. In this setup, a wide range angular scan allowed a possibility to \textit{in situ} investigate different crystal working regimes (channeling, volume reflection, etc.), and to measure a bent crystal torsion.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.
-
Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment
Authors:
F. M. Addesa,
L. Burmistrov,
D. Breton,
G. Cavoto,
V. Chaumat,
S. Dubos,
L. Esposito,
F. Galluccio,
M. Garattini,
F. Iacoangeli,
J. Maalmi,
D. Mirarchi,
A. Natochii,
V. Puill,
R. Rossi,
W. Scandale,
S. Montesano,
A. Stocchi
Abstract:
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on…
▽ More
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on thin fused silica bars in the beam pipe vacuum which intercept charged particles and generate Cherenkov light. The first version of the CpFM is installed since 2015 in the crystal-assisted collimation setup of the UA9 experiment. In this paper the procedures to make the detector operational and fully integrated in the UA9 setup are described. The most important standard operations of the detector are presented. They have been used to commission and characterize the detector, providing moreover the measurement of the integrated channeled beam profile and several functionality tests as the determination of the crystal bending angle.
The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and the results are applied to the flux measurement discussed here in detail.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
Experimental results of crystal-assisted slow extraction at the SPS
Authors:
M. A. Fraser,
F. Addesa,
G. Cavoto,
F. Galluccio,
S. Gilardoni,
B. Goddard,
F. Iacoangeli,
V. Kain,
D. Mirarchi,
S. Montesano,
F. Murtas,
S. Petrucci,
S. Redaelli,
R. Rossi,
W. Scandale,
L. Stoel
Abstract:
The possibility of extracting highly energetic particles from the Super Proton Synchrotron (SPS) by means of silicon bent crystals has been explored since the 1990's. The channelling effect of a bent crystal can be used to strongly deflect primary protons and eject them from the synchrotron. Many studies and experiments have been carried out to investigate crystal channelling effects. The extracti…
▽ More
The possibility of extracting highly energetic particles from the Super Proton Synchrotron (SPS) by means of silicon bent crystals has been explored since the 1990's. The channelling effect of a bent crystal can be used to strongly deflect primary protons and eject them from the synchrotron. Many studies and experiments have been carried out to investigate crystal channelling effects. The extraction of 120 and 270 GeV proton beams has already been demonstrated in the SPS with dedicated experiments located in the ring. Presently in the SPS, the UA9 experiment is performing studies to evaluate the possibility to use bent silicon crystals to steer particle beams in high energy accelerators. Recent studies on the feasibility of extraction from the SPS have been made using the UA9 infrastructure with a longer-term view of using crystals to help mitigate slow extraction induced activation of the SPS. In this paper, the possibility to eject particles into the extraction channel in LSS2 using the bent crystals already installed in the SPS is presented. Details of the concept, simulations and measurements carried out with beam are presented, before the outlook for the future is discussed.
△ Less
Submitted 17 July, 2017;
originally announced July 2017.