-
The Mu2e crystal and SiPM calorimeter: construction status
Authors:
Nikolay Atanov,
Vladimir Baranov,
Leo Borrel,
Caterina Bloise,
Julian Budagov,
Sergio Ceravol,
Franco Cervelli,
Francesco Colao,
Marco Cordelli,
Giovanni Corradi,
Yuri Davydov,
Stefano Di Falco,
Eleonora Diociaiuti,
Simone Donati,
Bertrand Echenard,
Carlo Ferrari,
Ruben Gargiulo,
Antonio Gioiosa,
Simona Giovannella,
Valerio Giusti,
Vladimir Glagolev,
Francesco Grancagnolo,
Dariush Hampai,
Fabio Happacher,
David Hitlin
, et al. (15 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilitie…
▽ More
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this paper, we present the status of construction and the Quality Control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.
△ Less
Submitted 28 January, 2024;
originally announced January 2024.
-
Mu2e-II: Muon to electron conversion with PIP-II
Authors:
K. Byrum,
S. Corrodi,
Y. Oksuzian,
P. Winter,
L. Xia,
A. W. J. Edmonds,
J. P. Miller,
J. Mott,
W. J. Marciano,
R. Szafron,
R. Bonventre,
D. N. Brown,
Yu. G. Kolomensky,
O. Ning,
V. Singh,
E. Prebys,
L. Borrel,
B. Echenard,
D. G. Hitlin,
C. Hu,
D. X. Lin,
S. Middleton,
F. C. Porter,
L. Zhang,
R. -Y. Zhu
, et al. (83 additional authors not shown)
Abstract:
An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for exa…
▽ More
An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for examining the process on additional target materials. Mu2e-II is a proposed upgrade to Mu2e, with at least an additional order of magnitude in sensitivity to the conversion rate over Mu2e. The approach and challenges for this proposal are summarized. Mu2e-II may be regarded as the next logical step in a continued high-intensity muon program at FNAL.
△ Less
Submitted 16 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Study of energy response and resolution of the ATLAS Tile Calorimeter to hadrons of energies from 16 to 30 GeV
Authors:
Jalal Abdallah,
Stylianos Angelidakis,
Giorgi Arabidze,
Nikolay Atanov,
Johannes Bernhard,
Romeo Bonnefoy,
Jonathan Bossio,
Ryan Bouabid,
Fernando Carrio,
Tomas Davidek,
Michal Dubovsky,
Luca Fiorini,
Francisco Brandan Garcia Aparisi,
Tancredi Carli,
Alexander Gerbershagen,
Hazal Goksu,
Haleh Hadavand,
Siarhei Harkusha,
Dingane Hlaluku,
Michael James Hibbard,
Kevin Hildebrand,
Juansher Jejelava,
Andrey Kamenshchikov,
Stergios Kazakos,
Tomas Kello
, et al. (46 additional authors not shown)
Abstract:
Three spare modules of the ATLAS Tile Calorimeter were exposed to test beams from the Super Proton Synchrotron accelerator at CERN in 2017. The measurements of the energy response and resolution of the detector to positive pions and kaons and protons with energy in the range 16 to 30 GeV are reported. The results have uncertainties of few percent. They were compared to the predictions of the Geant…
▽ More
Three spare modules of the ATLAS Tile Calorimeter were exposed to test beams from the Super Proton Synchrotron accelerator at CERN in 2017. The measurements of the energy response and resolution of the detector to positive pions and kaons and protons with energy in the range 16 to 30 GeV are reported. The results have uncertainties of few percent. They were compared to the predictions of the Geant4-based simulation program used in ATLAS to estimate the response of the detector to proton-proton events at Large Hadron Collider. The determinations obtained using experimental and simulated data agree within the uncertainties.
△ Less
Submitted 8 February, 2021;
originally announced February 2021.
-
Paschen curve for a PCB trace in low vacuum
Authors:
N. Atanov,
S. Bini,
S. Ceravolo,
G. Corradi,
R. Donghia
Abstract:
For one PCB trace region, where bare high voltage trace goes near GND pad, we estimated an electrical breakdown voltage in low vacuum using simplified geometrical model under some assumptions. Experimental measurement of Paschen curve for the PCB board considered was proceed in pressure range from 2x10-3 mbar to 25 mbar.
For one PCB trace region, where bare high voltage trace goes near GND pad, we estimated an electrical breakdown voltage in low vacuum using simplified geometrical model under some assumptions. Experimental measurement of Paschen curve for the PCB board considered was proceed in pressure range from 2x10-3 mbar to 25 mbar.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
Authors:
S. Xiao,
S. Alderweireldt,
S. Ali,
C. Allaire,
C. Agapopoulou,
N. Atanov,
M. K. Ayoub,
G. Barone,
D. Benchekroun,
A. Buzatu,
D. Caforio,
L. Castillo García,
Y. Chan,
H. Chen,
V. Cindro,
L. Ciucu,
J. Barreiro Guimarães da Costa,
H. Cui,
F. Davó Miralles,
Y. Davydov,
G. d'Amen,
C. de la Taille,
R. Kiuchi,
Y. Fan,
A. Falou
, et al. (75 additional authors not shown)
Abstract:
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated wi…
▽ More
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
Authors:
X. Shi,
M. K. Ayoub,
J. Barreiro Guimarães da Costa,
H. Cui,
R. Kiuchi,
Y. Fan,
S. Han,
Y. Huang,
M. Jing,
Z. Liang,
B. Liu,
J. Liu,
F. Lyu,
B. Qi,
K. Ran,
L. Shan,
L. Shi,
Y. Tan,
K. Wu,
S. Xiao,
T. Yang,
Y. Yang,
C. Yu,
M. Zhao,
X. Zhuang
, et al. (52 additional authors not shown)
Abstract:
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the co…
▽ More
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
Authors:
X. Yang,
S. Alderweireldt,
N. Atanov,
M. K. Ayoub,
J. Barreiro Guimaraes da Costa,
L. Castillo Garcia,
H. Chen,
S. Christie,
V. Cindro,
H. Cui,
G. D'Amen,
Y. Davydov,
Y. Y. Fan,
Z. Galloway,
J. J. Ge,
C. Gee,
G. Giacomini,
E. L. Gkougkousis,
C. Grieco,
S. Grinstein,
J. Grosse-Knetter,
S. Guindon,
S. Han,
A. Howard,
Y. P. Huang
, et al. (54 additional authors not shown)
Abstract:
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising…
▽ More
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Mu2e calorimeter readout system
Authors:
N. Atanov,
V. Baranov,
L. Baldini,
J. Budagov,
D. Caiulo,
F. Cei,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
F. D'Errico,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Faetti,
S. Giovannella,
S. Giudici,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
L. Lazzeri
, et al. (21 additional authors not shown)
Abstract:
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to o…
▽ More
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.
△ Less
Submitted 9 July, 2019;
originally announced July 2019.
-
The Mu2e calorimeter: quality assurance of production crystals and SiPMs
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
D. Caiulo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi
, et al. (12 additional authors not shown)
Abstract:
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples pre…
▽ More
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceram…
▽ More
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.
△ Less
Submitted 21 February, 2018;
originally announced February 2018.
-
Design and status of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous ex…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
The Mu2e Calorimeter Final Technical Design Report
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane,
Y. Davydov,
S. Di Falco,
S. Donati,
E. Diociaiuti,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi
, et al. (15 additional authors not shown)
Abstract:
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout…
▽ More
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
The Mu2e crystal calorimeter
Authors:
N. Atanov,
J. Budagov,
F. Cervelli,
F. Colao,
Y Davidov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo,
F. Porter,
A. Saputi,
I. Sarra,
F. Spinella,
G. Tassielli
Abstract:
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slight…
▽ More
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates
%\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{μe} = \frac{μ^- + A(Z,N) \to e^- +A(Z,N)}{μ^- + A(Z,N) \to ν_μ ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.).
This will improve the current limit of four order of magnitudes with respect to the previous best experiment.
Mu2e complements and extends the current search for $μ\to e γ$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} μ/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.
△ Less
Submitted 30 January, 2018;
originally announced January 2018.
-
Design, status and perspective of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
E. Diociaiuti,
M. Cordelli,
G. Corradi,
E. Danè,
Yu. Davydov,
S. Donati,
R. Donghia,
S. Di Falco,
B. Echenard,
L. Morescalchi,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker an…
▽ More
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.
△ Less
Submitted 18 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
The Mu2e undoped CsI crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigg…
▽ More
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.
△ Less
Submitted 22 February, 2018; v1 submitted 7 January, 2018;
originally announced January 2018.
-
Quality Assurance on a custom SiPMs array for the Mu2e experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain…
▽ More
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
The calorimeter of the Mu2e experiment at Fermilab
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dané,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data tak…
▽ More
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.
△ Less
Submitted 27 January, 2017;
originally announced January 2017.
-
Design and status of the Mu2e electromagnetic calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
R. Carosi,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane',
Yu. I. Davydov,
S. Di Falco,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic…
▽ More
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.
△ Less
Submitted 8 August, 2016;
originally announced August 2016.
-
Design, status and test of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
R. Carosi,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Danè,
Y. I. Davydov,
S. Di Falco,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with about 700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. These crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.
△ Less
Submitted 1 July, 2016; v1 submitted 17 June, 2016;
originally announced June 2016.
-
Energy and time resolution for a LYSO matrix prototype of the Mu2e experiment
Authors:
N. Atanov,
V. Baranov,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane`,
Y. I. Davydov,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Ott,
G. Pezzullo,
A. Saputi,
I. Sarra,
S. R. Soleti,
G. Tassielli,
V. Tereshchenko,
A. Thomas
Abstract:
We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60$-$450 MeV. This study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.
We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60$-$450 MeV. This study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.
△ Less
Submitted 30 May, 2016;
originally announced May 2016.
-
Measurement of time resolution of the Mu2e LYSO calorimeter prototype
Authors:
N. Atanov,
V. Baranov,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dané,
Yu. I. Davydov,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
G. Pezzullo,
A. Saputi,
I. Sarra,
S. R. Soleti,
G. Tassielli,
V. Tereshchenko
Abstract:
In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the $e^-$ beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm$^3$, LYSO crystals read out by 10…
▽ More
In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the $e^-$ beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm$^3$, LYSO crystals read out by 10x10 mm$^2$ Hamamatsu Avalanche Photodiodes (APDs). The energy dependence of the measured time resolution can be parametrized as $σ_{t}(E)=a/\sqrt{E/\mathrm{GeV}} \oplus b$, with the stochastic and constant terms $a=(51\pm1)$ ps and $b=(10\pm4)$ ps, respectively. This corresponds to the time resolution of ($162\pm4$) ps at 100 MeV.
△ Less
Submitted 11 January, 2016; v1 submitted 15 September, 2015;
originally announced September 2015.