(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–21 of 21 results for author: Bowles, M A

.
  1. Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

    Authors: SuperCDMS Collaboration, M. F. Albakry, I. Alkhatib, D. W. P. Amaral, T. Aralis, T. Aramaki, I. J. Arnquist, I. Ataee Langroudy, E. Azadbakht, S. Banik, C. Bathurst, D. A. Bauer, L. V. S. Bezerra, R. Bhattacharyya, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, M. Chaudhuri, R. Chen , et al. (104 additional authors not shown)

    Abstract: Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie… ▽ More

    Submitted 27 June, 2022; v1 submitted 14 February, 2022; originally announced February 2022.

    Journal ref: Phys. Rev. D 105, 122002 (2022)

  2. arXiv:2011.09183  [pdf, other

    hep-ex astro-ph.CO astro-ph.HE hep-ph physics.ins-det

    Constraints on Lightly Ionizing Particles from CDMSlite

    Authors: SuperCDMS Collaboration, I. Alkhatib, D. W. P. Amaral, T. Aralis, T. Aramaki, I. J. Arnquist, I. Ataee Langroudy, E. Azadbakht, S. Banik, D. Barker, C. Bathurst, D. A. Bauer, L. V. S. Bezerra, R. Bhattacharyya, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, M. Chaudhuri, R. Chen , et al. (93 additional authors not shown)

    Abstract: The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v… ▽ More

    Submitted 19 February, 2022; v1 submitted 18 November, 2020; originally announced November 2020.

    Journal ref: Phys. Rev. Lett. 127, 081802 (2021)

  3. arXiv:2007.14289  [pdf, ps, other

    hep-ex astro-ph.CO physics.ins-det

    Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

    Authors: I. Alkhatib, D. W. P. Amaral, T. Aralis, T. Aramaki, I. J. Arnquist, I. Ataee Langroudy, E. Azadbakht, S. Banik, D. Barker, C. Bathurst, D. A. Bauer, L. V. S. Bezerra, R. Bhattacharyya, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, M. Chaudhuri, R. Chen , et al. (99 additional authors not shown)

    Abstract: We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σしぐま_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte… ▽ More

    Submitted 12 October, 2021; v1 submitted 21 July, 2020; originally announced July 2020.

    Comments: 7 pages, 4 figures, this version includes ancillary files from official data release

    Journal ref: Phys. Rev. Lett. 127, 061801 (2021)

  4. arXiv:2005.14067  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

    Authors: SuperCDMS Collaboration, D. W. Amaral, T. Aralis, T. Aramaki, I. J. Arnquist, E. Azadbakht, S. Banik, D. Barker, C. Bathurst, D. A. Bauer, L. V. S. Bezerra, R. Bhattacharyya, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, R. Chen, N. Chott, J. Cooley , et al. (94 additional authors not shown)

    Abstract: This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a… ▽ More

    Submitted 29 January, 2021; v1 submitted 28 May, 2020; originally announced May 2020.

    Comments: 5 pages + title and references, 3 figures and 1 table

    Journal ref: Phys. Rev. D 102, 091101 (2020)

  5. arXiv:1911.11905  [pdf, other

    hep-ex physics.ins-det

    Constraints on dark photons and axion-like particles from SuperCDMS Soudan

    Authors: SuperCDMS Collaboration, T. Aralis, T. Aramaki, I. J. Arnquist, E. Azadbakht, W. Baker, S. Banik, D. Barker, C. Bathurst, D. A. Bauer, L. V. S Bezerra, R. Bhattacharyya, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, J. Cooley, H. Coombes, J. Corbett , et al. (82 additional authors not shown)

    Abstract: We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 5… ▽ More

    Submitted 18 January, 2021; v1 submitted 26 November, 2019; originally announced November 2019.

    Comments: 14 pages, 10 figures, 1 page correction included with 3 figures

    Journal ref: Phys. Rev. D 101, 052008 (2020)

  6. arXiv:1808.09098  [pdf, other

    astro-ph.CO physics.ins-det

    Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

    Authors: SuperCDMS Collaboration, R. Agnese, T. Aralis, T. Aramaki, I. J. Arnquist, E. Azadbakht, W. Baker, S. Banik, D. Barker, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, J. Cooley, B. Cornell, P. Cushman, F. De Brienne, T. Doughty , et al. (78 additional authors not shown)

    Abstract: The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than… ▽ More

    Submitted 2 January, 2021; v1 submitted 27 August, 2018; originally announced August 2018.

    Journal ref: Phys. Rev. D 99, 062001 (2019)

  7. arXiv:1806.07043  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex nucl-ex

    Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite

    Authors: SuperCDMS Collaboration, R. Agnese, T. Aralis, T. Aramaki, I. J. Arnquist, E. Azadbakht, W. Baker, D. Barker, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, C. Cartaro, D. G. Cerdeño, Y. -Y. Chang, J. Cooley, B. Cornell, P. Cushman, T. Doughty, E. Fascione, E. Figueroa-Feliciano, C. W. Fink , et al. (73 additional authors not shown)

    Abstract: Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod… ▽ More

    Submitted 16 August, 2019; v1 submitted 19 June, 2018; originally announced June 2018.

    Comments: 14 pages, 10 figures, 5 tables. v5 contains the extended data release (and documentation) of the CDMSlite Run 2 data as ancillary files

    Journal ref: R. Agnese et al. (SuperCDMS Collaboration), Astropart. Phys., 104 (2019) pp. 1-12

  8. arXiv:1804.10697  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector

    Authors: SuperCDMS Collaboration, R. Agnese, T. Aralis, T. Aramaki, I. J. Arnquist, E. Azadbakht, W. Baker, S. Banik, D. Barker, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, C. Cartaro, D. G. Cerdeno, Y. -Y. Chang, J. Cooley, B. Cornell, P. Cushman, P. C. F. Di Stefano, T. Doughty, E. Fascione , et al. (77 additional authors not shown)

    Abstract: We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit… ▽ More

    Submitted 22 December, 2020; v1 submitted 27 April, 2018; originally announced April 2018.

    Comments: 6 pages + title and references, 6 figures, includes erratum submitted to PRL and data release

    Journal ref: Phys. Rev. Lett. 121, 051301 (2018)

  9. arXiv:1803.02903  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

    Authors: R. Agnese, A. J. Anderson, T. Aramaki, W. Baker, D. Balakishiyeva, S. Banik, D. Barker, R. Basu Thakur, D. A. Bauer, T. Binder, A. Borgland, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeno, H. Chagani, Y. -Y. Chang, Y. Chen, J. Cooley, B. Cornell, P. Cushman , et al. (84 additional authors not shown)

    Abstract: The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol… ▽ More

    Submitted 27 July, 2018; v1 submitted 7 March, 2018; originally announced March 2018.

    Comments: 22 pages, 17 figures, 1 table, 1 appendix

  10. Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan

    Authors: SuperCDMS Collaboration, R. Agnese, T. Aramaki, I. J. Arnquist, W. Baker, D. Balakishiyeva, S. Banik, D. Barker, R. Basu Thakur, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeño, Y. Chang, Y. Chen, J. Cooley, B. Cornell, P. Cushman, M. Daal , et al. (79 additional authors not shown)

    Abstract: We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ (… ▽ More

    Submitted 29 August, 2017; originally announced August 2017.

    Journal ref: Phys. Rev. Lett. 120, 061802 (2018)

  11. arXiv:1707.01632  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Low-Mass Dark Matter Search with CDMSlite

    Authors: SuperCDMS Collaboration, R. Agnese, A. J. Anderson, T. Aralis, T. Aramaki, I. J. Arnquist, W. Baker, D. Balakishiyeva, D. Barker, R. Basu Thakur, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeno, Y. Chang, H. Chagani, Y. Chen, J. Cooley, B. Cornell , et al. (83 additional authors not shown)

    Abstract: The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is… ▽ More

    Submitted 18 January, 2018; v1 submitted 6 July, 2017; originally announced July 2017.

    Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files

    Journal ref: Phys. Rev. D 97, 022002 (2018)

  12. arXiv:1610.00006  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Projected Sensitivity of the SuperCDMS SNOLAB experiment

    Authors: R. Agnese, A. J. Anderson, T. Aramaki, I. Arnquist, W. Baker, D. Barker, R. Basu Thakur, D. A. Bauer, A. Borgland, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeño, H. Chagani, Y. Chen, J. Cooley, B. Cornell, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty , et al. (71 additional authors not shown)

    Abstract: SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle… ▽ More

    Submitted 30 September, 2016; originally announced October 2016.

    Comments: SuperCDMS SNOLAB Projected sensitivity reach

    Journal ref: Phys. Rev. D 95, 082002 (2017)

  13. arXiv:1509.02448  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    WIMP-Search Results from the Second CDMSlite Run

    Authors: SuperCDMS Collaboration, R. Agnese, A. J. Anderson, T. Aramaki, M. Asai, W. Baker, D. Balakishiyeva, D. Barker, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, P. Cushman, M. Daal , et al. (65 additional authors not shown)

    Abstract: The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization… ▽ More

    Submitted 9 March, 2016; v1 submitted 8 September, 2015; originally announced September 2015.

    Comments: 6 pages, 4 figures. v2 Matches the accepted version in PRL

    Report number: IPPP/15/56, DCTP/15/112

    Journal ref: Phys. Rev. Lett. 116, 071301 (2016)

  14. arXiv:1504.05871  [pdf, other

    hep-ex astro-ph.CO

    Improved WIMP-search reach of the CDMS II germanium data

    Authors: R. Agnese, A. J. Anderson, M. Asai, D. Balakishiyeva, D. Barker, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, D. G. Cerdeño, H. Chagani, Y. Chen, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano , et al. (64 additional authors not shown)

    Abstract: CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity n… ▽ More

    Submitted 13 October, 2015; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 25 pages, 15 figures, slightly updated organization and text consistent with PRD referee process, Fig. 14 updated

    Report number: IPPP/15/24, DCTP/15/48

    Journal ref: Phys. Rev. D 92, 072003 (2015)

  15. arXiv:1410.1003  [pdf, other

    astro-ph.CO astro-ph.IM physics.ins-det

    Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data

    Authors: SuperCDMS Collaboration, R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban , et al. (62 additional authors not shown)

    Abstract: We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background… ▽ More

    Submitted 3 October, 2014; originally announced October 2014.

    Comments: 12 pages, 12 figures, submitted to PRD

    Journal ref: Phys. Rev. D 91, 052021 (2015)

  16. arXiv:1409.3270  [pdf, other

    hep-ex astro-ph.CO astro-ph.HE physics.ins-det

    First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$

    Authors: R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban, S. Fallows , et al. (60 additional authors not shown)

    Abstract: While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six… ▽ More

    Submitted 3 February, 2015; v1 submitted 10 September, 2014; originally announced September 2014.

    Comments: 5 pages, 6 figures, submitted to PRL

    Journal ref: Phys. Rev. Lett. 114, 111302 (2015)

  17. arXiv:1404.5843  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Removal of long-lived $^{222}$Rn daughters by electropolishing thin layers of stainless steel

    Authors: R. W. Schnee, M. A. Bowles, R. Bunker, K. McCabe, J. White, P. Cushman, M. Pepin, V. E. Guiseppe

    Abstract: Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay. Removal of tens of microns of material via electropolishing has been shown to be effective at removing radon daughters implanted into material surfaces. Some applications, however, require the re… ▽ More

    Submitted 23 April, 2014; originally announced April 2014.

    Comments: 4 pages, 4 figures, Proceedings of Low Radioactivity Techniques (LRT) 2013, Gran Sasso, Italy, April 10-12, 2013

    Journal ref: AIP Conf.Proc.1549:128-131,2013

  18. arXiv:1404.5803  [pdf, other

    physics.ins-det hep-ex

    The BetaCage, an ultra-sensitive screener for surface contamination

    Authors: R. Bunker, Z. Ahmed, M. A. Bowles, S. R. Golwala, D. R. Grant, M. Kos, R. H. Nelson, R. W. Schnee, A. Rider, B. Wang, A. Zahn

    Abstract: Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocontamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive)… ▽ More

    Submitted 23 April, 2014; originally announced April 2014.

    Comments: 5 pages, 3 figures, Proceedings of Low Radioactivity Techniques (LRT) 2013, Gran Sasso, Italy, April 10-12, 2013

    Journal ref: AIP Conf.Proc.1549:132-135,2013

  19. arXiv:1402.7137  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Search for Low-Mass WIMPs with SuperCDMS

    Authors: R. Agnese, A. J. Anderson, M. Asai, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Beaty, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, M. Cherry, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, D. DeVaney , et al. (70 additional authors not shown)

    Abstract: We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i… ▽ More

    Submitted 12 March, 2014; v1 submitted 28 February, 2014; originally announced February 2014.

    Comments: 6 pages, 4 figures; figure 1 updated, submitted to Phys. Rev. Lett

    Journal ref: Phys. Rev. Lett. 112, 241302 (2014)

  20. arXiv:1309.3259  [pdf, ps, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment

    Authors: R. Agnese, A. J. Anderson, M. Asai, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban, S. Fallows , et al. (55 additional authors not shown)

    Abstract: SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll… ▽ More

    Submitted 20 December, 2013; v1 submitted 12 September, 2013; originally announced September 2013.

    Comments: 7 pages, 4 figures

    Journal ref: Phys. Rev. Lett. 112, 041302 (2014)

  21. arXiv:1307.6154  [pdf, other

    physics.ins-det hep-ex

    A prototype low-background multiwire proportional chamber for measuring alphas and low-energy betas

    Authors: Z. Ahmed, M. A. Bowles, R. Bunker, S. R. Golwala, D. R. Grant, M. Kos, R. H. Nelson, A. Rider, R. W. Schnee, D. Sotolongo, B. Wang, A. Zahn

    Abstract: A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants for future rare-event-search experiments as well as other scientific fields. The design features and assembly techniques described here are motivated by the pos… ▽ More

    Submitted 24 November, 2013; v1 submitted 23 July, 2013; originally announced July 2013.

    Comments: 18 pages, 9 figures