-
You Can Tell a Cybercriminal by the Company they Keep: A Framework to Infer the Relevance of Underground Communities to the Threat Landscape
Authors:
Michele Campobasso,
Radu Rădulescu,
Sylvan Brons,
Luca Allodi
Abstract:
The criminal underground is populated with forum marketplaces where, allegedly, cybercriminals share and trade knowledge, skills, and cybercrime products. However, it is still unclear whether all marketplaces matter the same in the overall threat landscape. To effectively support trade and avoid degenerating into scams-for-scammers places, underground markets must address fundamental economic prob…
▽ More
The criminal underground is populated with forum marketplaces where, allegedly, cybercriminals share and trade knowledge, skills, and cybercrime products. However, it is still unclear whether all marketplaces matter the same in the overall threat landscape. To effectively support trade and avoid degenerating into scams-for-scammers places, underground markets must address fundamental economic problems (such as moral hazard, adverse selection) that enable the exchange of actual technology and cybercrime products (as opposed to repackaged malware or years-old password databases). From the relevant literature and manual investigation, we identify several mechanisms that marketplaces implement to mitigate these problems, and we condense them into a market evaluation framework based on the Business Model Canvas. We use this framework to evaluate which mechanisms `successful' marketplaces have in place, and whether these differ from those employed by `unsuccessful' marketplaces. We test the framework on 23 underground forum markets by searching 836 aliases of indicted cybercriminals to identify `successful' marketplaces. We find evidence that marketplaces whose administrators are impartial in trade, verify their sellers, and have the right economic incentives to keep the market functional are more likely to be credible sources of threat.
△ Less
Submitted 13 June, 2023; v1 submitted 9 June, 2023;
originally announced June 2023.
-
A Beam Monitor for Ion Beam Therapy based on HV-CMOS Pixel Detectors
Authors:
Matthias Balzer,
Alexander Dierlamm,
Felix Ehrler,
Ulrich Husemann,
Roland Koppenhöfer,
Ivan Perić,
Martin Pittermann,
Bogdan Topko,
Alena Weber,
Stephan Brons,
Jürgen Debus,
Nicole Grau,
Thomas Hansmann,
Oliver Jäkel,
Sebastian Klüter,
Jakob Naumann
Abstract:
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth dependent energy deposition, which can be exploited to accurately deposit dose in the tumor cells. To guarantee this, high accu…
▽ More
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth dependent energy deposition, which can be exploited to accurately deposit dose in the tumor cells. To guarantee this, high accuracy of monitoring and control of the particle beam is of utmost importance. Before the particle beam enters the patient, it traverses a monitoring system which has to give fast feedback to the beam control system on position and dose rate of the beam while minimally interacting with the beam. The multi-wire chambers mostly used as beam position monitor have their limitations when fast response time is required (drift time). Future developments like MRI-guided ion beam therapy pose additional challenges for the beam monitoring system like tolerance of magnetic fields and acoustic noise (vibrations). Solid-state detectors promise to overcome these limitations and the higher resolution they offer can create additional benefits. This article presents the evaluation of an HV-CMOS detector for beam monitoring, provides results from feasibility studies in a therapeutic beam and summarizes the concepts towards the final large-scale assembly and readout system.
△ Less
Submitted 11 November, 2022;
originally announced November 2022.
-
Does FLASH deplete Oxygen? Experimental Evaluation for Photons, Protons and Carbon Ions
Authors:
Jeannette Jansen,
Jan Knoll,
Elke Beyreuther,
Jörg Pawelke,
Raphael Skuza,
Rachel Hanley,
Stephan Brons,
Francesca Pagliari,
Joao Seco
Abstract:
Purpose: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons and carbon ions.
Methods: This study presents measurements of the oxygen consumption in sealed, 3D printed water phantoms during irradiation with X-rays, protons and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed…
▽ More
Purpose: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons and carbon ions.
Methods: This study presents measurements of the oxygen consumption in sealed, 3D printed water phantoms during irradiation with X-rays, protons and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed using an optical sensor allowing for non-invasive measurements.
Results: Oxygen consumption in water only depends on dose, dose rate and linear energy transfer (LET) of the irradiation. The total amount of oxygen depleted per 10 Gy was found to be 0.04 - 0.18 % atm for 225 kV photons, 0.04 - 0.25 % atm for 224 MeV protons and 0.09 - 0.17 % atm for carbon ions. consumption depends on dose rate by an inverse power law and saturates for higher dose rates because of self-interactions of radicals. Higher dose rates yield lower oxygen consumption. No total depletion of oxygen was found for clinical doses.
Conclusions: FLASH irradiation does consume oxygen, but not enough to deplete all the oxygen present. For higher dose rates, less oxygen was consumed than at standard radiotherapy dose rates. No total depletion was found for any of the analyzed radiation types for 10 Gy dose delivery using FLASH.
△ Less
Submitted 1 March, 2021; v1 submitted 25 February, 2021;
originally announced February 2021.
-
Absorbed Dose in Ion Beams: Comparison of Ionisation and Fluence-based Measurements
Authors:
Julia-Maria Osinga,
Stephan Brons,
James A. Bartz,
Mark S. Akselrod,
Oliver Jäkel,
Steffen Greilich
Abstract:
A direct comparison measurement of fluorescent nuclear track detectors (FNTDs) and a thimble ionisation chamber is presented. Irradiations were performed using monoenergetic protons (142.66 MeV, 3*10^6 1/cm2) and carbon ions (270.55 MeV/u, 3*10^6 1/cm2). It was found that absorbed dose to water values as determined by fluence measurements using FNTDs are, in case of protons, in good agreement (2.4…
▽ More
A direct comparison measurement of fluorescent nuclear track detectors (FNTDs) and a thimble ionisation chamber is presented. Irradiations were performed using monoenergetic protons (142.66 MeV, 3*10^6 1/cm2) and carbon ions (270.55 MeV/u, 3*10^6 1/cm2). It was found that absorbed dose to water values as determined by fluence measurements using FNTDs are, in case of protons, in good agreement (2.4 %) with ionization chamber measurements, if slower protons and Helium secondaries were accounted for by an effective stopping power. For carbon, however, a significant discrepancy of 4.5 % was seen, which could not be explained by fragmentation, uncertainties or experimental design. The results rather suggest a W-value of 32.10 eV +/- 2.6 %. Additionally, the abundance of secondary protons expected from Monte-Carlo transport simulation was not observed.
△ Less
Submitted 3 February, 2014; v1 submitted 6 June, 2013;
originally announced June 2013.
-
Observation of a resonance in the K$_s$p decay channel at a mass of 1765 MeV/c$^2$
Authors:
WA89 Collaboration,
M. I. Adamovich,
Yu. A. Alexandrov,
D. Barberis,
M. Beck,
C. Bérat,
W. Beusch,
M. Boss,
S. Brons,
W. Brückner,
M. Buénerd,
C. Busch,
C. Büscher,
F. Charignon,
J. Chauvin,
E. A. Chudakov,
U. Dersch,
F. Dropmann,
J. Engelfried,
F. Faller,
A. Fournier,
S. G. Gerassimov,
M. Godbersen,
P. Grafström,
Th. Haller
, et al. (38 additional authors not shown)
Abstract:
We report on the observation of a K$_s$p resonance signal at a mass of 1765$\pm$5 MeV/c$^2$, with intrinsic width $Γ= 108\pm 22$ MeV/c$^2$, produced inclusively in $Σ^-$-nucleus interactions at 340 GeV/c in the hyperon beam experiment WA89 at CERN. The signal was observed in the kinematic region $x_F>0.7$, in this region its production cross section rises approximately linearly with $(1-x_F)$, r…
▽ More
We report on the observation of a K$_s$p resonance signal at a mass of 1765$\pm$5 MeV/c$^2$, with intrinsic width $Γ= 108\pm 22$ MeV/c$^2$, produced inclusively in $Σ^-$-nucleus interactions at 340 GeV/c in the hyperon beam experiment WA89 at CERN. The signal was observed in the kinematic region $x_F>0.7$, in this region its production cross section rises approximately linearly with $(1-x_F)$, reaching $BR(X\to K_S p)\cdot dσ/dx_F = (5.2\pm 2.3) μb $ per nucleon at $x_F=0.8$. The hard \xf spectrum suggests the presence of a strong leading particle effect in the production and hence the identification as a $Σ^{*+}$ state. No corresponding peaks were observed in the $K^- p$ and $Λπ^{\pm}$ mass spectra.
△ Less
Submitted 27 February, 2007;
originally announced February 2007.