-
Measurement of the $ν_e$ and Total $^{8}$B Solar Neutrino Fluxes with the Sudbury Neutrino Observatory Phase-III Data Set
Authors:
B. Aharmim,
S. N. Ahmed,
J. F. Amsbaugh,
J. M. Anaya,
A. E. Anthony,
J. Banar,
N. Barros,
E. W. Beier,
A. Bellerive,
B. Beltran,
M. Bergevin,
S. D. Biller,
K. Boudjemline,
M. G. Boulay,
T. J. Bowles,
M. C. Browne,
T. V. Bullard,
T. H. Burritt,
B. Cai,
Y. D. Chan,
D. Chauhan,
M. Chen,
B. T. Cleveland,
G. A. Cox,
C. A. Currat
, et al. (125 additional authors not shown)
Abstract:
This paper details the solar neutrino analysis of the 385.17-day Phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of $^3$He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active $^8$B solar neutrino flux was largely independent of the…
▽ More
This paper details the solar neutrino analysis of the 385.17-day Phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of $^3$He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active $^8$B solar neutrino flux was largely independent of the methods employed in previous phases. The total flux of active neutrinos was measured to be $5.54^{+0.33}_{-0.31}(stat.)^{+0.36}_{-0.34}(syst.)\times 10^{6}$ cm$^{-2}$ s$^{-1}$, consistent with previous measurements and standard solar models. A global analysis of solar and reactor neutrino mixing parameters yielded the best-fit values of $Δm^2 = 7.59^{+0.19}_{-0.21}\times 10^{-5}{eV}^2$ and $θ= 34.4^{+1.3}_{-1.2}$ degrees.
△ Less
Submitted 14 July, 2011;
originally announced July 2011.
-
An array of low-background $^3$He proportional counters for the Sudbury Neutrino Observatory
Authors:
J. F. Amsbaugh,
J. M. Anaya,
J. Banar,
T. J. Bowles,
M. C. Browne,
T. V. Bullard,
T. H. Burritt,
G. A. Cox-Mobrand,
X. Dai,
H. Deng,
M. Di Marco,
P. J. Doe,
M. R. Dragowsky,
C. A. Duba,
F. A. Duncan,
E. D. Earle,
S. R. Elliott,
E. -I. Esch,
H. Fergani,
J. A. Formaggio,
M. M. Fowler,
J. E. Franklin,
P. Geissbühler,
J. V. Germani,
A. Goldschmidt
, et al. (49 additional authors not shown)
Abstract:
An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consis…
▽ More
An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consisted of 36 strings of proportional counters filled with a mixture of $^3$He and CF$_4$ gas capable of detecting the neutrons liberated by the neutrino-deuteron neutral current reaction in the D$_2$O, and four strings filled with a mixture of $^4$He and CF$_4$ gas for background measurements. The proportional counter diameter is 5 cm. The total deployed array length was 398 m. The SNO NCD array is the lowest-radioactivity large array of proportional counters ever produced. This article describes the design, construction, deployment, and characterization of the NCD array, discusses the electronics and data acquisition system, and considers event signatures and backgrounds.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.
-
Temperature behavior of NaI (Tl) scintillation detectors
Authors:
K. D. Ianakiev,
B. S. Alexandrov,
P. B. Littlewood,
M. C. Browne
Abstract:
It is a familiar fact that the total measured light yield of NaI (Tl) detectors is a nonlinear function of temperature. Here we present new experimental data for the temperature behavior of doped NaI(Tl) scintillators that instead shows a linear dependence of light output over a wide temperature range- including that for outdoor applications. The shape of the light pulse shows in general two dec…
▽ More
It is a familiar fact that the total measured light yield of NaI (Tl) detectors is a nonlinear function of temperature. Here we present new experimental data for the temperature behavior of doped NaI(Tl) scintillators that instead shows a linear dependence of light output over a wide temperature range- including that for outdoor applications. The shape of the light pulse shows in general two decay processes: a single dominant process above room temperature and two decay time constants below. We show that redistribution of the intensities is temperature-dependent; the second (slow) decay component is negligible at room temperatures, but, by -20C, it contributes up to 40 percents of the total light and has a duration of several microseconds. We discuss the profound effect this new understanding of the light output has on the pulse height analysis instrumentation. We introduce a theoretical model to explain the experimental results. In addition, we describe a unique technique for correcting both amplitude and shape temperature changes inside the NaI(Tl) detector package.
△ Less
Submitted 30 May, 2006;
originally announced May 2006.
-
New Limit on the D Coefficient in Polarized Neutron Decay
Authors:
L. J. Lising,
S. R. Hwang,
J. M. Adams,
T. J. Bowles,
M. C. Browne,
T. E. Chupp,
K. P. Coulter,
M. S. Dewey,
S. J. Freedman,
B. K. Fujikawa,
A. Garcia,
G. L. Greene,
G. L. Jones,
H. P. Mumm,
J. S. Nico,
J. M. Richardson,
R. G. H. Robertson,
T. D. Steiger,
W. A. Teasdale,
A. K. Thompson,
E. G. Wasserman,
F. E. Wietfeldt,
R. C. Welsh,
J. F. Wilkerson
Abstract:
We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contrib…
▽ More
We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contributions to T violation due to leptoquarks. This paper presents details of the experiment, data analysis, and the investigation of systematic effects.
△ Less
Submitted 19 July, 2000; v1 submitted 1 June, 2000;
originally announced June 2000.
-
A Compact 3H(p,gamma)4He 19.8-MeV Gamma-Ray Source for Energy Calibration at the Sudbury Neutrino Observatory
Authors:
A. W. P. Poon,
R. J. Komar,
C. E. Waltham,
M. C. Browne,
R. G. H. Robertson,
N. P. Kherani,
H. B. Mak
Abstract:
The Sudbury Neutrino Observatory (SNO) is a new 1000-tonne D2O Cerenkov solar neutrino detector. A high energy gamma-ray source is needed to calibrate SNO beyond the 8B solar neutrino endpoint of 15 MeV. This paper describes the design and construction of a source that generates 19.8-MeV gamma rays using the 3H(p,gamma)4He reaction (``pt''), and demonstrates that the source meets all the physica…
▽ More
The Sudbury Neutrino Observatory (SNO) is a new 1000-tonne D2O Cerenkov solar neutrino detector. A high energy gamma-ray source is needed to calibrate SNO beyond the 8B solar neutrino endpoint of 15 MeV. This paper describes the design and construction of a source that generates 19.8-MeV gamma rays using the 3H(p,gamma)4He reaction (``pt''), and demonstrates that the source meets all the physical, operational and lifetime requirements for calibrating SNO. An ion source was built into this unit to generate and to accelerate protons up to 30 keV, and a high purity scandium tritide target with a scandium-tritium atomic ratio of 1:2.0+/-0.2 was included. This pt source is the first self-contained, compact, and portable high energy gamma-ray source (E>10 MeV).
△ Less
Submitted 29 February, 2000; v1 submitted 8 October, 1999;
originally announced October 1999.