-
Comparing continuous and pulsed nitrogen-vacancy DC magnetometry in the optical-power-limited regime
Authors:
Maggie Wang,
Michael Caouette-Mansour,
Adrian Solyom,
Lilian Childress
Abstract:
Ensembles of nitrogen-vacancy (NV) center spins in diamond offer a robust, precise and accurate magnetic sensor. As their applications move beyond the laboratory, practical considerations including size, complexity, and power consumption become important. Here, we compare two commonly-employed NV magnetometry techniques -- continuous-wave (CW) vs pulsed magnetic resonance -- in a scenario limited…
▽ More
Ensembles of nitrogen-vacancy (NV) center spins in diamond offer a robust, precise and accurate magnetic sensor. As their applications move beyond the laboratory, practical considerations including size, complexity, and power consumption become important. Here, we compare two commonly-employed NV magnetometry techniques -- continuous-wave (CW) vs pulsed magnetic resonance -- in a scenario limited by total available optical power. We develop a consistent theoretical model for the magnetic sensitivity of each protocol that incorporates NV photophysics - in particular, including the incomplete spin polarization associated with limited optical power; after comparing the models' behaviour to experiments, we use them to predict the relative DC sensitivity of CW versus pulsed operation for an optical-power-limited, shot-noise-limited NV ensemble magnetometer. We find a $\sim 2-3 \times$ gain in sensitivity for pulsed operation, which is significantly smaller than seen in power-unlimited, single-NV experiments. Our results provide a resource for practical sensor development, informing protocol choice and identifying optimal operation regimes when optical power is constrained.
△ Less
Submitted 10 November, 2023;
originally announced November 2023.
-
Single-spin spectroscopy of spontaneous and phase-locked spin torque oscillator dynamics
Authors:
Adrian Solyom,
Michael Caouette-Mansour,
Brandon Ruffolo,
Patrick Braganca,
Lilian Childress,
Jack Sankey
Abstract:
We employ N-$V$ magnetometry to measure the stray field dynamics of a ferromagnetic permalloy nanowire driven by spin-orbit torques. Specifically, we observe the optically detected magnetic resonance (ODMR) signatures of both spontaneous DC-driven magnetic oscillations and phase-locking to a second harmonic drive, developing a simple macrospin model that captures the salient features. We also obse…
▽ More
We employ N-$V$ magnetometry to measure the stray field dynamics of a ferromagnetic permalloy nanowire driven by spin-orbit torques. Specifically, we observe the optically detected magnetic resonance (ODMR) signatures of both spontaneous DC-driven magnetic oscillations and phase-locking to a second harmonic drive, developing a simple macrospin model that captures the salient features. We also observe signatures of dynamics beyond the macrospin model, including an additional ODMR feature (associated with a second SW mode) and one mode sapping power from another. Our results provide additional insight into N-$V$-spin wave coupling mechanisms, and represent a new modality for sub-wavelength N-$V$ scanned probe microscopy of nanoscale magnetic oscillators.
△ Less
Submitted 29 July, 2023;
originally announced July 2023.
-
Robust spin relaxometry with fast adaptive Bayesian estimation
Authors:
Michael Caouette-Mansour,
Adrian Solyom,
Brandon Ruffolo,
Robert D. McMichael,
Jack Sankey,
Lilian Childress
Abstract:
Spin relaxometry with nitrogen-vacancy (NV) centers in diamond offers a spectrally selective, atomically localized, and calibrated measurement of microwave-frequency magnetic noise, presenting a versatile probe for condensed matter and biological systems. Typically, relaxation rates are estimated with curve-fitting techniques that do not provide optimal sensitivity, often leading to long acquisiti…
▽ More
Spin relaxometry with nitrogen-vacancy (NV) centers in diamond offers a spectrally selective, atomically localized, and calibrated measurement of microwave-frequency magnetic noise, presenting a versatile probe for condensed matter and biological systems. Typically, relaxation rates are estimated with curve-fitting techniques that do not provide optimal sensitivity, often leading to long acquisition times that are particularly detrimental in systems prone to drift or other dynamics of interest. Here we show that adaptive Bayesian estimation is well suited to this problem, producing dynamic relaxometry pulse sequences that rapidly find an optimal operating regime. In many situations (including the system we employ), this approach can speed the acquisition by an order of magnitude. We also present a four-signal measurement protocol that is robust to drifts in spin readout contrast, polarization, and microwave pulse fidelity while still achieving near-optimal sensitivity. The combined technique offers a practical, hardware-agnostic approach for a wide range of NV relaxometry applications.
△ Less
Submitted 17 April, 2023; v1 submitted 24 February, 2022;
originally announced February 2022.
-
Onset field for Fermi-surface reconstruction in the cuprate superconductor YBCO
Authors:
G. Grissonnanche,
F. Laliberte,
S. Dufour-Beausejour,
A. Riopel,
S. Badoux,
M. Caouette-Mansour,
M. Matusiak,
A. Juneau-Fecteau,
P. Bourgeois-Hope,
O. Cyr-Choiniere,
J. C. Baglo,
B. J. Ramshaw,
R. Liang,
D. A. Bonn,
W. N. Hardy,
S. Kramer,
D. LeBoeuf,
D. Graf,
N. Doiron-Leyraud,
Louis Taillefer
Abstract:
Quantum oscillations and negative Hall and Seebeck coefficients at low temperature and high magnetic field have shown the Fermi surface of underdoped cuprates to contain a small closed electron pocket. It is thought to result from a reconstruction by charge order, but whether it is the order seen by NMR and ultrasound above a threshold field or the short-range modulations seen by X-ray diffraction…
▽ More
Quantum oscillations and negative Hall and Seebeck coefficients at low temperature and high magnetic field have shown the Fermi surface of underdoped cuprates to contain a small closed electron pocket. It is thought to result from a reconstruction by charge order, but whether it is the order seen by NMR and ultrasound above a threshold field or the short-range modulations seen by X-ray diffraction in zero field is unclear. Here we use measurements of the thermal Hall conductivity in YBCO to show that Fermi-surface reconstruction occurs only above a sharply defined onset field, equal to the transition field seen in ultrasound. This reveals that electrons do not experience long-range broken translational symmetry in the zero-field ground state, and hence in zero field there is no quantum critical point for the onset of charge order as a function of doping.
△ Less
Submitted 22 August, 2015;
originally announced August 2015.