-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Focal-plane detector system for the KATRIN experiment
Authors:
J. F. Amsbaugh,
J. Barrett,
A. Beglarian,
T. Bergmann,
H. Bichsel,
L. I. Bodine,
J. Bonn,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
S. Chilingaryan,
T. J. Corona,
P. J. Doe,
J. A. Dunmore,
S. Enomoto,
J. Fischer,
J. A. Formaggio,
F. M. Fränkle,
D. Furse,
H. Gemmeke,
F. Glück,
F. Harms,
G. C. Harper,
J. Hartmann,
M. A. Howe
, et al. (26 additional authors not shown)
Abstract:
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electro…
▽ More
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
△ Less
Submitted 28 January, 2015; v1 submitted 10 April, 2014;
originally announced April 2014.
-
Dead layer on silicon p-i-n diode charged-particle detectors
Authors:
B. L. Wall,
J. F. Amsbaugh,
A. Beglarian,
T. Bergmann,
H. C. Bichsel,
L. I. Bodine,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
T. J. Corona,
P. J. Doe,
S. Enomoto,
F. Harms,
G. C. Harper,
M. A. Howe,
E. L. Martin,
D. S. Parno,
D. A. Peterson,
L. Petzold,
P. Renschler,
R. G. H. Robertson,
J. Schwarz,
M. Steidl,
T. D. Van Wechel,
B. A. VanDevender
, et al. (3 additional authors not shown)
Abstract:
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-…
▽ More
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.
△ Less
Submitted 7 October, 2013; v1 submitted 4 October, 2013;
originally announced October 2013.
-
The KATRIN Pre-Spectrometer at reduced Filter Energy
Authors:
M. Prall,
P. Renschler,
F. Glück,
A. Beglarian,
H. Bichsel,
L. Bornschein,
Z. Chaoui,
G. Drexlin,
F. Fränkle,
S. Görhardt,
S. Mertens,
M. Steidl,
Th. Thümmler,
S. Wüstling,
C. Weinheimer,
S. Zadorozhny
Abstract:
The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An ultra-low background of about b = 10 mHz is among the requirements to reach this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E filter type…
▽ More
The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An ultra-low background of about b = 10 mHz is among the requirements to reach this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E filter type are used in a tandem configuration. This setup, however, produces a Penning trap which could lead to increased background. We have performed test measurements showing that the filter energy of the pre-spectrometer can be reduced by several keV in order to diminish this trap. These measurements were analyzed with the help of a complex computer simulation, modeling multiple electron reflections both from the detector and the photoelectric electron source used in our test setup.
△ Less
Submitted 12 March, 2012;
originally announced March 2012.