-
Advanced Virgo: a 2nd generation interferometric gravitational wave detector
Authors:
F. Acernese,
M. Agathos,
K. Agatsuma,
D. Aisa,
N. Allemandou,
A. Allocca,
J. Amarni,
P. Astone,
G. Balestri,
G. Ballardin,
F. Barone,
J. -P. Baronick,
M. Barsuglia,
A. Basti,
F. Basti,
Th. S. Bauer,
V. Bavigadda,
M. Bejger,
M. G. Beker,
C. Belczynski,
D. Bersanetti,
A. Bertolini,
M. Bitossi,
M. A. Bizouard,
S. Bloemen
, et al. (209 additional authors not shown)
Abstract:
Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two A…
▽ More
Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two Advanced LIGO detectors in the US and GEO HF in Germany, with the goal of contributing to the early detections of gravitational waves and to opening a new observation window on the universe. In this paper we describe the main features of the Advanced Virgo detector and outline the status of the construction.
△ Less
Submitted 16 October, 2014; v1 submitted 18 August, 2014;
originally announced August 2014.
-
Test in a beam of large-area Micromegas chambers for sampling calorimetry
Authors:
C. Adloff,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
R. Gaglione,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
I. Koletsou,
F. Peltier,
J. Samarati,
G. Vouters
Abstract:
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider exp…
▽ More
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1$\times$1 m$^{2}$ were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility.
△ Less
Submitted 3 May, 2014;
originally announced May 2014.
-
Recent results of Micromegas sDHCAL with a new readout chip
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
S. Tsigaridas,
Y. Tsipolitis,
G. Vouters
Abstract:
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the active medium of a hadronic calorimeter. A chamber of 1 m2 with 9216 channels read out by a low noise front-end ASIC called MICROROC has recently been construct…
▽ More
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the active medium of a hadronic calorimeter. A chamber of 1 m2 with 9216 channels read out by a low noise front-end ASIC called MICROROC has recently been constructed and tested. Chamber design, ASIC circuitry and preliminary test beam results are reported.
△ Less
Submitted 3 February, 2012;
originally announced February 2012.
-
Micromegas for imaging hadronic calorimetry
Authors:
C. Adloff,
J. Blaha,
S. Cap,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation studies with emphasis on the comparison of the physics performance of the analog and digital readout is described. The developed prototypes are with 2 bit digital readout to exploit the Micromegas proportional mode and t…
▽ More
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation studies with emphasis on the comparison of the physics performance of the analog and digital readout is described. The developed prototypes are with 2 bit digital readout to exploit the Micromegas proportional mode and thus improve the calorimeter linearity. In addition, measurements of detection efficiency, hit multiplicity, and energy shower profiles obtained during the exposure of small size prototypes to radioactive source quanta, cosmic particles and accelerator beams are reported. Eventually, the status of a large scale chamber (1{\times}1 m2) are also presented with prospective towards the construction of a 1 m3 digital calorimeter consisting of 40 such chambers.
△ Less
Submitted 7 February, 2011;
originally announced February 2011.
-
MICROMEGAS chambers for hadronic calorimetry at a future linear collider
Authors:
C. Adloff,
D. Attie,
J. Blaha,
S. Cap,
M. Chefdeville,
P. Colas,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
I. Giomataris,
J. Jaquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and press…
▽ More
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented.
△ Less
Submitted 21 September, 2009; v1 submitted 17 September, 2009;
originally announced September 2009.