-
A novel harmonic klystron configuration for high power microwave frequency conversion
Authors:
Alberto Leggieri,
Mostafa Behtouei,
Graeme Burt,
Valery Dolgashev,
Franco Di Paolo,
Bruno Spataro
Abstract:
A new frequency converter, operating at significantly higher power and efficiency than previous devices, is described in this paper. The proposed device is implemented as a klystron structure where a new design principle is used. New analytical formulas and a specific design procedure are proposed. The klystron frequency multiplier can be suitable for telecommunications and non-lethal weapon, scie…
▽ More
A new frequency converter, operating at significantly higher power and efficiency than previous devices, is described in this paper. The proposed device is implemented as a klystron structure where a new design principle is used. New analytical formulas and a specific design procedure are proposed. The klystron frequency multiplier can be suitable for telecommunications and non-lethal weapon, scientific and medical particle accelerators while the most interested exploitations are in the field of high gradient particle acceleration and FEL devices for which no performant sources exist. The advanced klystron multiplier can replace all the low level circuitry for frequency multiplication as a less expensive alternative. Efficiencies in the range of 60% in the K-band range with power levels of 30 MW are possible without phase noise, sideband generation, jitter or chirp effects. The presented design principle is applicable to other bands or power levels.
△ Less
Submitted 7 March, 2023; v1 submitted 23 December, 2022;
originally announced December 2022.
-
High Gradient Testing of off-Axis Coupled C-band Cu and CuAg Accelerating Structures
Authors:
Mitchell Schneider,
Muhammed Zuboraj,
Valery Dolgashev,
John J Lewellen,
Sami G Tantawi,
Ryan Fleming,
Dmitry Gorelov,
Mark Middendorf,
Emilio A Nanni,
Evgenya I Simakov
Abstract:
We report the results of high gradient testing of two single cell off axis coupled standing wave accelerating structures. Two brazed standing wave side coupled structures with the same geometry were tested one made of pure copper Cu and one made of a copper silver CuAg alloy with silver concentration of 0.08 percent. A peak surface electric field of 450 MV per m was achieved in the CuAg structure…
▽ More
We report the results of high gradient testing of two single cell off axis coupled standing wave accelerating structures. Two brazed standing wave side coupled structures with the same geometry were tested one made of pure copper Cu and one made of a copper silver CuAg alloy with silver concentration of 0.08 percent. A peak surface electric field of 450 MV per m was achieved in the CuAg structure for a klystron input power of 14.5 MW and a 1 mirco s pulse length which was 25 percent higher than the peak surface electric field achieved in the Cu structure. The superb high gradient performance was achieved because of the two major optimizations in the cavity geometry 1 the shunt impedance of the cavity was maximized for a peak surface electric field to accelerating gradient ratio of 2 for a fully relativistic particle 2 the peak magnetic field enhancement due to the input coupler was minimized to limit pulse heating. These tests allow us to conclude that C band accelerating structures can operate at peak fields similar to those at higher frequencies while providing a larger beam iris for improved beam transport.
△ Less
Submitted 30 October, 2022;
originally announced October 2022.
-
Investigations on the multi-sector hard X-Band Structures
Authors:
V. A. Dolgashev,
L. Faillace,
M. Migliorati,
B. Spataro
Abstract:
The development of high gradient accelerating structures is one of the leading activities of the accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made from hard copper alloys, can achieve better performance as compare…
▽ More
The development of high gradient accelerating structures is one of the leading activities of the accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made from hard copper alloys, can achieve better performance as compared with soft copper ones. The results of experiments showed that welded, hard copper cavities have shown breakdown rate of $10^{-3}$/pulse/meter at a gradient of about 150 MV/m, in the X-band, a using a shaped pulse with a 150 ns flat part. We continue the design, construction, and higher power experimental tests of three cells standing wave (SW) 11.424 GHz accelerating cavities fabricated with hard CuAg alloy to study the RF breakdown physics. Our aim is to fabricate the accelerating structures with innovative technologies easier to handle and cheaper; easier for surfaces inspection; easier for data elaboration and validation of joining techniques. The choice of these new technological approaches and design methods provides also the possibility of allocating the parasitic Higher Order Mode dampers. This paper describes the design of an optimized cavity made with sectors which provides a high longitudinal shunt impedance $R_{sh}$ of the operating mode. The cavity will be fabricated by using the Tungsten Inert Gas process to realize a hard CuAg structure. Two three-cells SW X-band accelerating cavities, to be operated in the $π$-mode and made out of hard CuAg alloy, were already fabricated at INFN-LNF by means of clamping and welding by using the TIG approach. Finally, we also report the RF characterization and low-power RF tests of a two-halves split hard CuAg structure that will be consequently TIG welded and employed for high-gradient tests and for the study of the RF breakdown physics.
△ Less
Submitted 7 July, 2022;
originally announced July 2022.
-
A hard open X-band RF accelerating structure made by two halves
Authors:
Bruno Spataro,
Mostafa Behtouei,
Fabio Cardelli,
Martina Carillo,
Valery Dolgashev,
Luigi Faillace,
Mauro Migliorati,
Luigi Palumbo
Abstract:
High-gradient linacs of next generation require novel accelerating structures which are compact, robust and cost-effective. Dedicated research and development have been launched in the linear-collider community. This paper focuses on the technological developments directed to show the viability of novel welding techniques and related applications, in order to benefit from the superior high-gradien…
▽ More
High-gradient linacs of next generation require novel accelerating structures which are compact, robust and cost-effective. Dedicated research and development have been launched in the linear-collider community. This paper focuses on the technological developments directed to show the viability of novel welding techniques and related applications, in order to benefit from the superior high-gradient performance of accelerating structures made of hard-copper alloys. The structure geometry that we propose allows getting a high longitudinal shunt impedance of the accelerating mode and increasing the mode separation frequencies.
△ Less
Submitted 8 September, 2021;
originally announced September 2021.
-
Ultra-Compact Ka-band linearizer for the Ultra-Compact X-Ray Free-Electron Laser at UCLA
Authors:
Bruno Spataro,
Mostafa Behtouei,
Luigi Faillace,
Alessandro Variola,
Valery Dolgashev,
James Rosenzweig,
Giuseppe Torrisi,
Mauro Migliorati
Abstract:
Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFEL is able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized…
▽ More
Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFEL is able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary researches in chemistry, biology, materials science, medicine and physics.
In the framework of the Ultra -Compact XFEL project (UC-XFEL) under study at the UCLA, an ultra high gradient higher harmonic RF accelerating structure for the longitudinal space phase linearization is foreseen. To this aim, a Ka-Band linearizer (34.2 GHz) with an integrated voltage of at least 15 MV working on 6th harmonic with respect to the main Linac frequency (5.712 GHz) is required. We here present the electromagnetic design of a cold ultra compact Ka-band SW linearizer, 8 cm long, working on pi mode with an ultra high accelerating gradient (beyond 100 MV/m) and minimum surface electric field for minimizing the probability of RF breakdown. Moreover, we discuss a TW option and compare it with the initial SW structure, by means of main RF parameters as well as beam-dynamics considerations. The numerical electromagnetic studies have been performed by using the well known SuperFish, HFSS and CST.
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Ultra-High Brightness Electron Beams from Very-High Field Cryogenic Radio-frequency Photocathode Sources
Authors:
J. B. Rosenzweig,
A. Cahill,
B. Carlsten,
G. Castorina,
M. Croia,
C. Emma,
A. Fukusawa,
B. Spataro,
D. Alesini,
V. Dolgashev,
M. Ferrario,
G. Lawler,
R. Li,
C. Limborg,
J. Maxson,
P. Musumeci,
R. Pompili,
S. Tantawi,
O. Williams
Abstract:
Recent investigations of RF copper structures operated at cryogenic temperatures performed by a SLAC-UCLA collaboration have shown a dramatic increase in the maximum surface electric field, to 500 MV/m. We examine use of these fields to enable very high field cryogenic photoinjectors that can attain over an order of magnitude increase in peak electron beam brightness. We present beam dynamics stud…
▽ More
Recent investigations of RF copper structures operated at cryogenic temperatures performed by a SLAC-UCLA collaboration have shown a dramatic increase in the maximum surface electric field, to 500 MV/m. We examine use of these fields to enable very high field cryogenic photoinjectors that can attain over an order of magnitude increase in peak electron beam brightness. We present beam dynamics studies relevant to X-ray FEL injectors, using start-to-end simulations that show the high brightness and low emittance of this source enables operation of a compact FEL reaching a photon energy of 80 keV. The preservation of beam brightness in compression, exploiting micro-bunching techniques is discussed. While the gain in brightness at high field is due to increase of the emission current density, further increases in brightness due to lowering of the intrinsic cathode emittance in cryogenic operation are also enabled. While the original proposal for this type of cryogenic, ultra-high field photoinjector has emphasized S-band designs, there are numerous potential advantages that may be conferred by operation in C-band. We examine issues related to experimental implementation in C-band, and expected performance of this type of device in a future hard X-ray FEL such as MaRIE.
△ Less
Submitted 20 January, 2018;
originally announced January 2018.
-
Next Generation High Brightness Electron Beams From Ultra-High Field Cryogenic Radiofrequency Photocathode Sources
Authors:
J. B. Rosenzweig,
A. Cahill,
V. Dolgashev,
C. Emma,
A. Fukusawa,
R. Li,
C. Limborg,
J. Maxson,
P. Musumeci,
A. Nause,
R. Pakter,
R. Pompili,
R. Roussel,
B. Spataro,
S. Tantawi
Abstract:
Recent studies of the performance of radio-frequency (RF) copper cavities operated at cryogenic temperatures have shown a dramatic increase in the maximum achievable surface electric field. We propose to exploit this development to enable a new generation of photoinjectors operated at cryogenic temperatures that may attain, through enhancement of the launch field at the photocathode, a significant…
▽ More
Recent studies of the performance of radio-frequency (RF) copper cavities operated at cryogenic temperatures have shown a dramatic increase in the maximum achievable surface electric field. We propose to exploit this development to enable a new generation of photoinjectors operated at cryogenic temperatures that may attain, through enhancement of the launch field at the photocathode, a significant increase in five-dimensional electron beam brightness. We present detailed studies of the beam dynamics associated with such a system, by examining an S-band photoinjector operated at 250 MV/m peak electric field that reaches normalized emittances in the 40 nm-rad range at charges (100-200 pC) suitable for use in a hard X-ray free-electron laser (XFEL) scenario based on the LCLS. In this case, we show by start-to-end simulations that the properties of this source may give rise to high efficiency operation of an XFEL, and permit extension of the photon energy reach by an order of magnitude, to over 80 keV. The brightness needed for such XFELs is achieved through low source emittances in tandem with high current after compression. In the XFEL examples analyzed, the emittances during final compression are preserved using micro-bunching techniques. Extreme low emittance scenarios obtained at pC charge, appropriate for significantly extending temporal resolution limits of ultrafast electron diffraction and microscopy experiments, are also reviewed. While the increase in brightness in a cryogenic photoinjector is mainly due to the augmentation of the emission current density via field enhancement, further possible increases in performance arising from lowering the intrinsic cathode emittance in cryogenic operation are also analyzed. Issues in experimental implementation, including cavity optimization for lowering cryogenic thermal dissipation, external coupling, and cryo-cooler system are discussed.
△ Less
Submitted 30 December, 2018; v1 submitted 4 March, 2016;
originally announced March 2016.
-
Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz
Authors:
W. S. Graves,
J. Bessuille,
P. Brown,
S. Carbajo,
V. Dolgashev,
K. -H. Hong,
E. Ihloff,
B. Khaykovich,
H. Lin,
K. Murari,
E. A. Nanni,
G. Resta,
S. Tantawi,
L. E. Zapata,
F. X. Kärtner,
D. E. Moncton
Abstract:
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and RF photoinjector powered by a single ultrastable RF transmitter at x-…
▽ More
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and RF photoinjector powered by a single ultrastable RF transmitter at x-band RF frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. The entire accelerator is approximately 1 meter long and produces hard x-rays tunable over a wide range of photon energies. The colliding laser is a Yb:YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is $5 \times 10^{11}$ photons/second in a 5% bandwidth and the brilliance is $2 \times 10^{12}\mathrm{photons/(sec\ mm^2\ mrad^2\ 0.1\%)}$ in pulses with RMS pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.
△ Less
Submitted 9 October, 2014; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Molybdenum sputtering film characterization for high gradient accelerating structures
Authors:
S. Bini,
B. Spataro,
A. Marcelli,
S. Sarti,
V. A. Dolgashev,
S. Tantawi,
A. D. Yeremian,
Y. Higashi,
M. G. Grimaldi,
L. Romano,
F. Ruffino,
R. Parodi,
G. Cibin,
C. Marrelli,
M. Migliorati,
C. Caliendo
Abstract:
Technological advancements are strongly required to fulfill the demands of new accelerator devices with the highest accelerating gradients and operation reliability for the future colliders. To this purpose an extensive R&D regarding molybdenum coatings on copper is in progress. In this contribution we describe chemical composition, deposition quality and resistivity properties of different molybd…
▽ More
Technological advancements are strongly required to fulfill the demands of new accelerator devices with the highest accelerating gradients and operation reliability for the future colliders. To this purpose an extensive R&D regarding molybdenum coatings on copper is in progress. In this contribution we describe chemical composition, deposition quality and resistivity properties of different molybdenum coatings obtained via sputtering. The deposited films are thick metallic disorder layers with different resistivity values above and below the molibdenum dioxide reference value. Chemical and electrical properties of these sputtered coatings have been characterized by Rutherford backscattering, XANES and photoemission spectroscopy. We will also present a three cells standing wave section coated by a molybdenum layer $\sim$ 500 nm thick designed to improve the performance of X-Band accelerating systems.
△ Less
Submitted 26 December, 2012;
originally announced December 2012.
-
Wakefield damping for the CLIC crab cavity
Authors:
P. K. Ambattu,
G. Burt,
A. C. Dexter,
R. G. Carter,
V. Khan,
R. M. Jones,
V. Dolgashev
Abstract:
A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole ki…
▽ More
A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole kicks demand very high damping of the inter-bunch wakes, the major contributor to the luminosity loss of colliding bunches. This paper investigates the nature of the wakefields in the CLIC crab cavity and the possibility of using various damping schemes to suppress them effectively.
△ Less
Submitted 19 June, 2009;
originally announced June 2009.
-
X-band crab cavities for the CLIC beam delivery system
Authors:
G. Burt,
P. K. Ambattu,
A. C. Dexter,
T. Abram,
V. Dolgashev,
S. Tantawi,
R. M. Jones
Abstract:
The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision. The crab cavity is chosen to have the same frequency as the main linac (11.9942 GHz) as a compromise between size, phase stability requirements and beam loading…
▽ More
The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision. The crab cavity is chosen to have the same frequency as the main linac (11.9942 GHz) as a compromise between size, phase stability requirements and beam loading. It is proposed to use a HE11 mode travelling wave structure as the CLIC crab cavity in order to minimise beam loading and mode separation. The position of the crab cavity close to the final focus enhances the effect of transverse wake-fields so effective wake-field damping is required. A damped detuned structure is proposed to suppress and de-cohere the wake-field hence reducing their effect. Design considerations for the CLIC crab cavity will be discussed as well as the proposed high power testing of these structures at SLAC.
△ Less
Submitted 12 March, 2009;
originally announced March 2009.
-
Energy dispersion compensation and beam loading in X-band linacs for the JLC/NLC
Authors:
R. M. Jones,
V. A. Dolgashev,
R. H. Miller,
C. Adolphsen,
J. W. Wang
Abstract:
The shape of an RF pulse is distorted upon propagating through an X-band accelerator structure due to dispersive effects. This distortion together with beam loading introduce energy spread between 192 bunches. In order to minimize this energy spread we modify the input RF pulse shape. The pulse propagation, energy gain, and beam loading are modelled with a mode-matching computer code and a circu…
▽ More
The shape of an RF pulse is distorted upon propagating through an X-band accelerator structure due to dispersive effects. This distortion together with beam loading introduce energy spread between 192 bunches. In order to minimize this energy spread we modify the input RF pulse shape. The pulse propagation, energy gain, and beam loading are modelled with a mode-matching computer code and a circuit model. A 2D model and a circuit model of a complete 60 cm structure, consisting of 55 cells and input and output couplers is analyzed. This structure operates with a 5pi/6 phase advance per cell. Dispersive effects for this structure are more significant than for previously studied 2pi/3 phase advance accelerating structures. Experimental results are compared with the theoretical model and excellent agreement is obtained for the propagation of an RF pulse through the structure.
△ Less
Submitted 4 July, 2003;
originally announced July 2003.
-
Impedance Measurement Setup for Higher-Order Mode Studies in NLC Accelerator Structures with the Wire Method
Authors:
N. Baboi,
R. M. Jones,
J. W. Wang,
G. B. Bowden,
V. A. Dolgashev,
J. Lewandowski,
S. G. Tantawi,
P. B. Wilson
Abstract:
Dipole modes are the main cause of transverse emittance dilution in the Japanese Linear Collider / Next Linear Collider (JLC/NLC). A diagnostic setup has been built in order to investigate them. The method is based on using a coaxial wire to excite and measure electromagnetic modes of accelerating structures. This method can offer a more efficient and less expensive procedure than the ASSET faci…
▽ More
Dipole modes are the main cause of transverse emittance dilution in the Japanese Linear Collider / Next Linear Collider (JLC/NLC). A diagnostic setup has been built in order to investigate them. The method is based on using a coaxial wire to excite and measure electromagnetic modes of accelerating structures. This method can offer a more efficient and less expensive procedure than the ASSET facility. Initial measurements have been made and are presented in this paper.
△ Less
Submitted 19 September, 2002;
originally announced September 2002.
-
Wakefield Band Partitioning In Linac Structures
Authors:
R. M. Jones,
V. Dolgashev,
K. L. F. Bane,
E. Lin
Abstract:
In the NLC project multiple bunches of electrons and positrons will be accelerated initially to a centre of mass of 500 GeV and later to 1 TeV or more. In the process of accelerating 192 bunches within a pulse train, wakefields are excited which kick the trailing bunches off axis and can cause luminosity dilution and BBU (Beam Break Up). Several structures to damp the wakefield have been designe…
▽ More
In the NLC project multiple bunches of electrons and positrons will be accelerated initially to a centre of mass of 500 GeV and later to 1 TeV or more. In the process of accelerating 192 bunches within a pulse train, wakefields are excited which kick the trailing bunches off axis and can cause luminosity dilution and BBU (Beam Break Up). Several structures to damp the wakefield have been designed and tested at SLAC and KEK and these have been found to successfully damp the wakefield [1]. However, these 2pi/3 structures suffered from electrical breakdown and this has prompted us to explore lower group velocity structures operating at higher fundamental mode phase advances. The wakefield partitioning amongst the bands has been found to change markedly with increased phase advance. Here we report on general trends in the kick factor and associated wakefield band partitioning in dipole bands as a function of phase advance of the synchronous mode in linacs. These results are applicable to both TW (travelling wave) and SW (standing wave) structures [1] R.M. Jones et al, PAC99, also SLAC-PUB-8103
△ Less
Submitted 23 August, 2002;
originally announced August 2002.
-
Coaxial Wire Measurements In NLC Accelerating Structures
Authors:
N. Baboi,
R. M. Jones,
G. B. Bowden,
V. Dolgashev,
S. G. Tantawi,
J. W. Wang
Abstract:
The coaxial wire method provides an experimental way of measuring wake fields without the need for a particle beam. A special setup has been designed and is in the process of being fabricated at SLAC to measure the loss factors and synchronous frequencies of dipole modes in both traveling and standing wave structures for the Next Linear Collider (NLC). The method is described and predictions bas…
▽ More
The coaxial wire method provides an experimental way of measuring wake fields without the need for a particle beam. A special setup has been designed and is in the process of being fabricated at SLAC to measure the loss factors and synchronous frequencies of dipole modes in both traveling and standing wave structures for the Next Linear Collider (NLC). The method is described and predictions based on electromagnetic field simulations are discussed
△ Less
Submitted 27 June, 2002;
originally announced June 2002.
-
Room temperature accelerator structures for linear colliders
Authors:
R. H. Miller,
R. M. Jones,
C. Adolphsen,
G. Bowden,
V. Dolgashev,
N. Kroll Z. Li,
R. Loewen,
C. Ng,
C. Pearson,
T. Raubenheimer R. Ruth,
S. Tantawi,
J. W. Wang
Abstract:
Early tests of short low group velocity and standing wave structures indicated the viability of operating X-band linacs with accelerating gradients in excess of 100 MeV/m. Conventional scaling of traveling wave traveling wave linacs with frequency scales the cell dimensions with l. Because Q scales as l1/2, the length of the structures scale not linearly but as l3/2 in order to preserve the atte…
▽ More
Early tests of short low group velocity and standing wave structures indicated the viability of operating X-band linacs with accelerating gradients in excess of 100 MeV/m. Conventional scaling of traveling wave traveling wave linacs with frequency scales the cell dimensions with l. Because Q scales as l1/2, the length of the structures scale not linearly but as l3/2 in order to preserve the attenuation through each structure. For NLC we chose not to follow this scaling from the SLAC S-band linac to its fourth harmonic at X-band. We wanted to increase the length of the structures to reduce the number of couplers and waveguide drives which can be a significant part of the cost of a microwave linac. Furthermore, scaling the iris size of the disk-loaded structures gave unacceptably high short range dipole wakefields. Consequently, we chose to go up a factor of about 5 in average group velocity and length of the structures, which increases the power fed to each structure by the same factor and decreases the short range dipole wakes by a similar factor. Unfortunately, these longer (1.8 m) structures have not performed nearly as well in high gradient tests as the short structures. We believe we have at least a partial understanding of the reason and will discuss it below. We are now studying two types of short structures with large apertures with moderately good efficiency including: 1) traveling wave structures with the group velocity lowered by going to large phase advance per period with bulges on the iris, 2) pi mode standing wave structures
△ Less
Submitted 29 August, 2001;
originally announced August 2001.
-
Design, fabrication and measurement of the first rounded damped detuned accelerator structure (RDDS1)
Authors:
J. W. Wang,
C. Adolphsen,
G. B. Bowden,
D. L. Burke,
J. Cornuelle,
V. A. Dolgashev,
W. B. Fowkes,
R. K. Jobe,
R. M. Jones,
K. Ko,
N. Kroll,
Z. Li,
R. J. Loewen,
D. McCormick,
R. H. Miller,
C. K. Ng,
C. Pearson,
T. O. Raubenhemer,
R. Reed,
M. Ross,
R. D. Ruth,
T. Smith,
G. Stupakov,
T. Higo,
Y. Funahashi
, et al. (8 additional authors not shown)
Abstract:
As a joint effort in the JLC/NLC research program, we have developed a new type of damped detuned accelerator structure with optimized round-shaped cavities (RDDS). This paper discusses some important R&D aspects of the first structure in this series (RDDS1). The design aspects covered are the cell design with sub-MHz precision, HOM detuning, coupling and damping technique and wakefield simulati…
▽ More
As a joint effort in the JLC/NLC research program, we have developed a new type of damped detuned accelerator structure with optimized round-shaped cavities (RDDS). This paper discusses some important R&D aspects of the first structure in this series (RDDS1). The design aspects covered are the cell design with sub-MHz precision, HOM detuning, coupling and damping technique and wakefield simulation. The fabrication issues covered are ultra-precision cell machining with micron accuracy, assembly and diffusion bonding technologies to satisfactorily meet bookshelf, straightness and cell rotational alignment requirements. The measurements described are the RF properties of single cavities and complete accelerator section, as well as wakefields from the ASSET tests at SLAC. Finally, future improvements are also discussed.
△ Less
Submitted 6 September, 2000;
originally announced September 2000.
-
Higher Dipole Bands in the NLC Accelerating Structure
Authors:
C. Adolphsen,
K. L. F. Bane,
V. A. Dolgashev,
K. Ko,
Z. Li,
R. Miller
Abstract:
We show that scattering matrix calculations for dipole modes between 23-43 GHz for the 206 cell detuned structure (DS) are consistent with finite element calculations and results of the uncoupled model. In particular, the rms sum wake for these bands is comparable to that of the first dipole band.
We also show that for RDDS1 uncoupled wakefield calculations for higher bands are consistent with…
▽ More
We show that scattering matrix calculations for dipole modes between 23-43 GHz for the 206 cell detuned structure (DS) are consistent with finite element calculations and results of the uncoupled model. In particular, the rms sum wake for these bands is comparable to that of the first dipole band.
We also show that for RDDS1 uncoupled wakefield calculations for higher bands are consistent with measurements. In particular, a clear 26 GHz signal in the short range wake is found in both results.
△ Less
Submitted 29 August, 2000;
originally announced August 2000.
-
2D Simulation of High-Efficiency Cross-Field RF Power Sources
Authors:
Valery A. Dolgashev,
Sami G. Tantawi
Abstract:
An efficient method for frequency domain analysis of 2D cross-field devices is presented. This work was done to analyze and design high efficiency magnetrons. Arbitrary device-geometries are described by a piecewise planar boundary. The method is based on an expansion of the electromagnetic fields into a set of cavity eigenmodes. In order to obtain the self-consistent solution, iterations are pe…
▽ More
An efficient method for frequency domain analysis of 2D cross-field devices is presented. This work was done to analyze and design high efficiency magnetrons. Arbitrary device-geometries are described by a piecewise planar boundary. The method is based on an expansion of the electromagnetic fields into a set of cavity eigenmodes. In order to obtain the self-consistent solution, iterations are performed until the energy balance is reached. A boundary integration method is used to take into account space charge effects. The cavity eigenmodes are found by a method based on the scattering matrix technique. The geometry is divided into regions. The boundary contour mode-matching method is used to obtain the scattering matrices for each region. Electromagnetic fields in each region are expanded into a series of plane waves. Due to choice of plane wave expansion, all integration in the mode-matching process is carried out analytically. The scattering matrices of the regions are combined using a generalized scattering matrix technique to obtain the scattering matrix for the full geometry, and then the eigenmode resonance frequencies and the fields. Periodic boundary condition is used for the field calculation and the particle tracking.
△ Less
Submitted 20 August, 2000;
originally announced August 2000.