-
Cross-calibration of atomic sensors for pressure metrology
Authors:
Erik Frieling,
Riley A. Stewart,
James L. Booth,
Kirk W. Madison
Abstract:
Atomic sensors have shown great promise for density and pressure metrology in the high, ultra-high, and extremely-high vacuum regimes. Specifically, the density of background gas particles in vacuum can be determined by measuring the collision rate between the particles and an ensemble of sensor atoms. This requires preparing the sensor atoms in a particular quantum state, observing the rate of ch…
▽ More
Atomic sensors have shown great promise for density and pressure metrology in the high, ultra-high, and extremely-high vacuum regimes. Specifically, the density of background gas particles in vacuum can be determined by measuring the collision rate between the particles and an ensemble of sensor atoms. This requires preparing the sensor atoms in a particular quantum state, observing the rate of changes of that state, and using the cross section coefficient for state-changing collisions to convert the rate into a corresponding density. The cross section can be known by various methods including by quantum scattering calculations using an ansatz for the interaction potential between the collision pair, by measurements of the post-collision sensor-atom momentum recoil distribution, or by empirical calibration of the sensor atom at a known density. Identifying systematic errors in the results of these methods can be aided by direct comparisons between them. Alternatively, measurements of different sensor atoms exposed to the same background gas offers another point of comparison free of the systematic errors inherent in creating a background gas at a known density. Here, we present such measurements for two sensor atoms, $^{87}$Rb and $^6$Li, and a variety of atomic and molecular background gases including H$_2$, N$_2$, Ar, Ne, Kr, and Xe. We find results consistent with, yet statistically different at the level of 3.5(5)%, from recent theoretical and experiment measurements. This work demonstrates a model-free method for transferring the primacy of one atomic standard to another sensor atom and highlights the utility of sensor-atom cross-calibration experiments to check the validity of direct measurements and theoretical predictions.
△ Less
Submitted 2 April, 2024; v1 submitted 24 December, 2023;
originally announced December 2023.
-
Cross-calibration of atomic pressure sensors and deviation from quantum diffractive collision universality for light particles
Authors:
Pinrui Shen,
Erik Frieling,
Katherine R. Herperger,
Denis Uhland,
Riley A. Stewart,
Avinash Deshmukh,
Roman V. Krems,
James L. Booth,
Kirk W. Madison
Abstract:
The total room-temperature, velocity-averaged cross section for atom-atom and atom-molecule collisions is well approximated by a universal function depending only on the magnitude of the leading order dispersion coefficient, $C_6$. This feature of the total cross section together with the universal function for the energy distribution transferred by glancing angle collisions ($P_{\rm{QDU}6}$) can…
▽ More
The total room-temperature, velocity-averaged cross section for atom-atom and atom-molecule collisions is well approximated by a universal function depending only on the magnitude of the leading order dispersion coefficient, $C_6$. This feature of the total cross section together with the universal function for the energy distribution transferred by glancing angle collisions ($P_{\rm{QDU}6}$) can be used to empirically determine the total collision cross section and realize a self-calibrating, vacuum pressure standard. This was previously validated for Rb+N$_2$ and Rb+Rb collisions. However, the post-collision energy distribution is expected to deviate from $P_{\rm{QDU}6}$ in the limit of small $C_6$ and small reduced mass. Here we observe this deviation experimentally by performing a direct cross-species loss rate comparison between Rb+H$_2$ and Li+H$_2$ and using the \textit{ab initio} value of $\langle σ_{\rm{tot}} \, v \rangle_{\rm{Li+H}_2}$. We find a velocity averaged total collision cross section ratio, $R = \langle σ_{\rm{tot}} \, v \rangle_{\rm{Li+H}_2} : \langle σ_{\rm{tot}} \, v \rangle_{\rm{Rb+H}_2} = 0.83(5)$. Based on an \textit{ab initio} computation of $\langle σ_{\rm{tot}} \, v \rangle_{\rm{Li+H}_2} = 3.13(6)\times 10^{-15}$ m$^3$/s, we deduce $\langle σ_{\rm{tot}} \, v \rangle_{\rm{Rb+H}_2} = 3.8(2) \times 10^{-15}$ m$^3$/s, in agreement with a Rb+H$_2$ \textit{ab initio} value of $\langle σ_{\mathrm{tot}} v \rangle_{\mathrm{Rb+H_2}} = 3.57 \times 10^{-15} \mathrm{m}^3/\mathrm{s}$.By contrast, fitting the Rb+H$_2$ loss rate as a function of trap depth to the universal function we find $\langle σ_{\rm{tot}} \, v \rangle_{\rm{Rb+H}_2} = 5.52(9) \times 10^{-15}$ m$^3$/s. Finally, this work demonstrates how to perform a cross-calibration of sensor atoms to extend and enhance the cold atom based pressure sensor.
△ Less
Submitted 12 September, 2022; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Observation of macroscopic valley-polarized monolayer exciton-polaritons at room temperature
Authors:
N. Lundt,
S. Stoll,
P. Nagler,
A. Nalitov,
S. Klembt,
S. Betzold,
J. W. Goddard,
E. Frieling,
A. V. Kavokin,
C. Schüller,
T. Korn,
S. Höfling,
C. Schneider
Abstract:
In this letter, we address the chiral properties of valley exciton-polaritons in a monolayer of WS2 in the regime of strong light-matter coupling with a Tamm-Plasmon resonance. We observe that the valley polarization, which manifests in the circular polarization of the emitted photoluminescence, is strongly enhanced in comparison to bare WS2 monolayers, and can even be observed under non-resonant…
▽ More
In this letter, we address the chiral properties of valley exciton-polaritons in a monolayer of WS2 in the regime of strong light-matter coupling with a Tamm-Plasmon resonance. We observe that the valley polarization, which manifests in the circular polarization of the emitted photoluminescence, is strongly enhanced in comparison to bare WS2 monolayers, and can even be observed under non-resonant excitation at ambient conditions. We study the relaxation and decay dynamics of exciton-polaritons in our device, and present a microscopic model to explain the wave vector-dependent valley depolarization as an interplay of bright and dark states, electron-hole exchange interaction and the linear polarization splitting inherent to the microcavity.
△ Less
Submitted 1 August, 2017;
originally announced August 2017.