-
Imaging High Jitter, Very Fast Phenomena: A Remedy for Shutter Lag
Authors:
Noah Hoppis,
Kathryn M. Sturge,
Jonathan E. Barney,
Brian L. Beaudoin,
Ariana M. Bussio,
Ashley E. Hammell,
Samuel L. Henderson,
James E. Krutzler,
Joseph P. Lichthardt,
Alexander H. Mueller,
Karl Smith,
Bryce C. Tappan,
Timothy W. Koeth
Abstract:
Dielectric breakdown is an example of a natural phenomenon that occurs on very short time scales, making it incredibly difficult to capture optical images of the process. Event initiation jitter is one of the primary challenges, as even a microsecond of jitter time can cause the imaging attempt to fail. Initial attempts to capture images of dielectric breakdown with a gigahertz frame rate camera a…
▽ More
Dielectric breakdown is an example of a natural phenomenon that occurs on very short time scales, making it incredibly difficult to capture optical images of the process. Event initiation jitter is one of the primary challenges, as even a microsecond of jitter time can cause the imaging attempt to fail. Initial attempts to capture images of dielectric breakdown with a gigahertz frame rate camera and an exploding bridge wire initiation were stymied by high initiation jitter. Subsequently, a novel optical delay line apparatus was developed in order to effectively circumvent the jitter and reliably image dielectric breakdown. The design and performance of the optical delay line apparatus are presented. The optical delay line increased the image capture success rate from 25% to 94% while also permitting enhanced temporal resolution and has applications for use in imaging other high-jitter, extremely fast phenomena.
△ Less
Submitted 21 December, 2023;
originally announced December 2023.
-
Obtaining high resolution excitation functions with an active thick-target approach and validating them with mirror nuclei
Authors:
S. Hudan,
J. E. Johnstone,
Rohit Kumar,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley,
W. W. von Seeger
Abstract:
Measurement of fusion excitation functions for stable nuclei has largely been restricted to nuclei with significant natural abundance. Typically, to investigate neighboring nuclei with low natural abundance has required obtaining isotopically enriched material. This restriction often limits the ability to perform such measurements. We report the measurement of a high quality fusion excitation func…
▽ More
Measurement of fusion excitation functions for stable nuclei has largely been restricted to nuclei with significant natural abundance. Typically, to investigate neighboring nuclei with low natural abundance has required obtaining isotopically enriched material. This restriction often limits the ability to perform such measurements. We report the measurement of a high quality fusion excitation function for a $^{17}$O beam produced from unenriched material with 0.038\% natural abundance. The measurement is enabled by using an active thick-target approach and the accuracy of the result is validated using its mirror nucleus $^{17}$F and resonances. The result provides important information about the average fusion cross-section for the oxygen isotopic chain as a function of neutron excess.
△ Less
Submitted 18 April, 2023;
originally announced April 2023.
-
First Measurement of the $B(E2; 3/2^- \rightarrow 1/2^-)$ Transition Strength in $^7$Be: Testing Ab Initio Predictions for $A=7$ Nuclei
Authors:
S. L. Henderson,
T. Ahn,
M. A. Caprio,
P. J. Fasano,
A. Simon,
W. Tan,
P. O'Malley,
J. Allen,
D. W. Bardayan,
D. Blankstein,
B. Frentz,
M. R. Hall,
J. J. Kolata,
A. E. McCoy,
S. Moylan,
C. S. Reingold,
S. Y. Strauss,
R. O. Torres-Isea
Abstract:
Electromagnetic observables are able to give insight into collective and emergent features in nuclei, including nuclear clustering. These observables also provide strong constraints for ab initio theory, but comparison of these observables between theory and experiment can be difficult due to the lack of convergence for relevant calculated values, such as $E2$ transition strengths. By comparing th…
▽ More
Electromagnetic observables are able to give insight into collective and emergent features in nuclei, including nuclear clustering. These observables also provide strong constraints for ab initio theory, but comparison of these observables between theory and experiment can be difficult due to the lack of convergence for relevant calculated values, such as $E2$ transition strengths. By comparing the ratios of $E2$ transition strengths for mirror transitions, we find that a wide range of ab initio calculations give robust and consistent predictions for this ratio. To experimentally test the validity of these ab initio predictions, we performed a Coulomb excitation experiment to measure the $B(E2; 3/2^- \rightarrow 1/2^-)$ transition strength in $^7$Be for the first time. A $B(E2; 3/2^- \rightarrow 1/2^-)$ value of $26(6)(3) \, e^2 \mathrm{fm}^4$ was deduced from the measured Coulomb excitation cross section. This result is used with the experimentally known $^7$Li $B(E2; 3/2^- \rightarrow 1/2^-)$ value to provide an experimental ratio to compare with the ab initio predictions. Our experimental value is consistent with the theoretical ratios within $1 σ$ uncertainty, giving experimental support for the value of these ratios. Further work in both theory and experiment can give insight into the robustness of these ratios and their physical meaning.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Remeasuring the anomalously enhanced $B(E2; 2^+ \rightarrow 1^+)$ in $^8\mathrm{Li}$
Authors:
S. L. Henderson,
T. Ahn,
P. J. Fasano,
A. E. McCoy,
S. Aguilar,
D. T. Blankstein,
L. Caves,
A. C. Dombos,
R. K. Grzywacz,
K. L. Jones,
S. Jin,
R. Kelmar,
J. J. Kolata,
P. D. O'Malley,
C. S. Reingold,
A. Simon,
K. Smith
Abstract:
The large reported $E2$ strength between the $2^+$ ground state and $1^+$ first excited state of $\isotope[8]{Li}$, $B(E2; 2^+ \rightarrow 1^+)= 55(15)\,e^2\fm^4$, presents a puzzle. Unlike in neighboring $A=7\text{--}9$ isotopes, where enhanced $E2$ strengths may be understood to arise from deformation as rotational in-band transitions, the $2^+\rightarrow1^+$ transition in $^8$Li cannot be under…
▽ More
The large reported $E2$ strength between the $2^+$ ground state and $1^+$ first excited state of $\isotope[8]{Li}$, $B(E2; 2^+ \rightarrow 1^+)= 55(15)\,e^2\fm^4$, presents a puzzle. Unlike in neighboring $A=7\text{--}9$ isotopes, where enhanced $E2$ strengths may be understood to arise from deformation as rotational in-band transitions, the $2^+\rightarrow1^+$ transition in $^8$Li cannot be understood in any simple way as a rotational in-band transition. Moreover, the reported strength exceeds \textit{ab initio} predictions by an order of magnitude. In light of this discrepancy, we revisited the Coulomb excitation measurement of this strength, now using particle-$γ$ coincidences, yielding a revised $B(E2; 2^+ \rightarrow 1^+)$ of $19(^{+7}_{-6})(2)$~e$^2$fm$^4$. We explore how this value compares to what might be expected in the limits of rotational models. While the present value is about a factor of three smaller than previously reported, it remains anomalously enhanced.
△ Less
Submitted 5 May, 2023; v1 submitted 13 September, 2021;
originally announced September 2021.
-
MuSIC@Indiana: an effective tool for accurate measurement of fusion with low-intensity radioactive beams
Authors:
J. E. Johnstone,
Rohit Kumar,
S. Hudan,
Varinderjit Singh,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. M. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley
Abstract:
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. Mu…
▽ More
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. MuSIC@Indiana was commissioned by measuring the $^{18}$O+$^{12}$C fusion excitation function for 11 $<$ E$_{cm}$ $<$ 20 MeV using CH$_{4}$ gas. A simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
The Notre-Dame Cube: An active-target time-projection chamber for radioactive beam experiments and detector development
Authors:
T. Ahn,
J. S. Randhawa,
S. Aguilar,
D. Blankstein,
L. Delgado,
N. Dixneuf,
S. L. Henderson,
W. Jackson,
L. Jensen,
S. Jin,
J. Koci,
J. J. Kolata,
J. Lai,
J. Levano,
X. Li,
A. Mubarak,
P. D. O'Malley,
S. Rameriz Martin,
M. Renaud,
M. Z. Serikow,
A. Tollefson,
J. Wilson,
L. Yan
Abstract:
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characte…
▽ More
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characterized. The ND-Cube was commissioned with a $^{7}$Li beam for measuring $^{40}$Ar + $^{7}$Li fusion reaction cross sections and investigating $^{7}$Li($α$,$α$)$^{7}$Li scattering events. The ND-Cube will be used to study a range of reactions using light radioactive ions produced at low energy.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Lifetime measurements of excited states in $^{15}$O
Authors:
B. Frentz,
A. Aprahamian,
A. M. Clark,
C. Dulal,
J. D. Enright,
R. J. deBoer,
J. Görres,
S. L. Henderson,
K. B. Howard,
R. Kelmar,
K. Lee,
L. Morales,
S. Moylan,
Z. Raman,
W. Tan,
L. E. Weghorn,
M. Wiescher
Abstract:
The CNO cycle is the main energy source in stars more massive than our sun, it defines the energy production and the cycle time that lead to the lifetime of massive stars, and it is an important tool for the determination of the age of globular clusters. One of the largest uncertainties in the CNO chain of reactions comes from the uncertainty in the $^{14}$N$(p,γ)^{15}$O reaction rate. This uncert…
▽ More
The CNO cycle is the main energy source in stars more massive than our sun, it defines the energy production and the cycle time that lead to the lifetime of massive stars, and it is an important tool for the determination of the age of globular clusters. One of the largest uncertainties in the CNO chain of reactions comes from the uncertainty in the $^{14}$N$(p,γ)^{15}$O reaction rate. This uncertainty arises predominantly from the uncertainty in the lifetime of the sub-threshold state in $^{15}$O at $E_{x}$ = 6792 keV. Previous measurements of this state's lifetime are significantly discrepant. Here, we report on a new lifetime measurement of this state, as well as the excited states in $^{15}$O at $E_{x}$ = 5181 keV and $E_{x}$ = 6172 keV, via the $^{14}$N$(p,γ)^{15}$O reaction at proton energies of $E_{p} = 1020$ keV and $E_{p} = 1570$ keV. The lifetimes have been determined with the Doppler-Shift Attenuation Method (DSAM) with three separate, nitrogen-implanted targets with Mo, Ta, and W backing. We obtained lifetimes from the weighted average of the three measurements, allowing us to account for systematic differences between the backing materials. For the 6792 keV state, we obtained a $τ= 0.6 \pm 0.4$ fs. To provide cross-validation of our method, we measured the known lifetimes of the states at 5181 keV and 6172 keV to be $τ= 7.5 \pm 3.0$ and $τ= 0.7 \pm 0.5$ fs, respectively, which are in good agreement with previous measurements.
△ Less
Submitted 23 December, 2020;
originally announced December 2020.