-
Calorimeter development for the SuperNEMO double beta decay experiment
Authors:
A. S. Barabash,
A. Basharina-Freshville,
S. Blot,
M. Bongrand,
Ch. Bourgeois,
D. Breton,
V. Brudanin,
H. Burešovà,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
E. Chauveau,
A. Chopra,
G. Claverie,
S. De Capua,
F. Delalee,
D. Duchesneau,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt,
D. Filosofov
, et al. (73 additional authors not shown)
Abstract:
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main…
▽ More
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $Δ$E/E, around 3%/$sqrt(E)$(MeV) $σ$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.
△ Less
Submitted 21 July, 2017;
originally announced July 2017.
-
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Authors:
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
S. Cebrián,
C. Cerna,
J. P Cesar,
E. Chauveau,
A. Chopra,
T. Dafní,
S. De Capua,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt
, et al. (71 additional authors not shown)
Abstract:
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been…
▽ More
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.
△ Less
Submitted 7 June, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Reference material for natural radionuclides in glass designed for underground experiments
Authors:
P. P. Povinec,
M. K. Pham,
J. Busto,
C. Cerna,
D. Degering,
Y. Hamajima,
K. Holy,
M. Hult,
M. Jeskovsky,
M. Koehler,
A. Kovacik,
M. Laubenstein,
P. Loaiza,
F. Mamedov,
C. Marquet,
J. Mott,
M. Mullerova,
F. Perrot,
F. Piquemal,
J. -L. Reyss,
R. Saakyan,
H. Simgen,
B. Soule,
J. Stanicek,
I. Sykora
, et al. (1 additional authors not shown)
Abstract:
A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participa…
▽ More
A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participating laboratories, however, the number of data and precision was too low to carry out a certification process. The reference material may be used for quality management of analytical laboratories engaged in the high-sensitive analysis of radionuclides in the construction materials of detectors placed in ultra low background underground laboratories.
△ Less
Submitted 12 July, 2015;
originally announced July 2015.
-
Probing New Physics Models of Neutrinoless Double Beta Decay with SuperNEMO
Authors:
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
A. Basharina-Freshville,
M. Bongrand,
V. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
F. F. Deppisch,
J. Diaz,
D. Durand,
V. Egorov,
J. J. Evans,
R. Flack,
K-I. Fushima,
I. García Irastorza,
X. Garrido,
H. Gómez,
B. Guillon,
A. Holin,
K. Holy
, et al. (57 additional authors not shown)
Abstract:
The possibility to probe new physics scenarios of light Majorana neutrino exchange and right-handed currents at the planned next generation neutrinoless double beta decay experiment SuperNEMO is discussed. Its ability to study different isotopes and track the outgoing electrons provides the means to discriminate different underlying mechanisms for the neutrinoless double beta decay by measuring th…
▽ More
The possibility to probe new physics scenarios of light Majorana neutrino exchange and right-handed currents at the planned next generation neutrinoless double beta decay experiment SuperNEMO is discussed. Its ability to study different isotopes and track the outgoing electrons provides the means to discriminate different underlying mechanisms for the neutrinoless double beta decay by measuring the decay half-life and the electron angular and energy distributions.
△ Less
Submitted 23 November, 2010; v1 submitted 7 May, 2010;
originally announced May 2010.
-
Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
A. Basharina-Freshville,
M. Bongrand,
C. Bourgeois,
D. Breton,
M. Briére,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
J. Díaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
R. Flack,
K-I. Fushima,
I. G. Irastorza,
X. Garrido
, et al. (64 additional authors not shown)
Abstract:
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the backg…
▽ More
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in $^{208}$Tl. After more than one year of background measurement, a surface activity of the scintillators of $\mathcal{A}$($^{208}$Tl) $=$ 1.5 $μ$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo detector having 12 m$^2$ of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of $\mathcal{A}$($^{208}$Tl) $<$ 2 $μ$Bq/kg (90% C.L.) with a six month measurement.
△ Less
Submitted 3 May, 2010;
originally announced May 2010.
-
Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
M. Bongrand,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
Z. Daraktchieva,
J. D iaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
N. Fatemi-Ghomi,
R. Flack,
A. Basharina-Freshville,
K-I. Fushimi,
X. Garrido,
H. Gómez,
B. Guillon
, et al. (68 additional authors not shown)
Abstract:
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is im…
▽ More
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.
△ Less
Submitted 8 November, 2010; v1 submitted 21 April, 2010;
originally announced April 2010.