-
In-flight gain monitoring of SPIDER's transition-edge sensor arrays
Authors:
J. P. Filippini,
A. E. Gambrel,
A. S. Rahlin,
E. Y. Young,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
A. A. Fraisse,
K. Freese,
M. Galloway,
N. N. Gandilo,
K. Ganga,
R. Gualtieri
, et al. (45 additional authors not shown)
Abstract:
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical respons…
▽ More
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical response that is exact in the limit of strong electrothermal feedback. We discuss the application and validation of this method using flight data from SPIDER, a balloon-borne telescope that observes the polarization of the cosmic microwave background with more than 2000 TESs. This method may prove useful for future balloon- and space-based instruments, where observing time and ground control bandwidth are limited.
△ Less
Submitted 16 June, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
A Simulation-Based Method for Correcting Mode Coupling in CMB Angular Power Spectra
Authors:
J. S. -Y. Leung,
J. Hartley,
J. M. Nagy,
C. B. Netterfield,
J. A. Shariff,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (45 additional authors not shown)
Abstract:
Modern CMB analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-…
▽ More
Modern CMB analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-$C_\ell$ based, MASTER-style analyses, the net effect of the time-domain filtering is commonly approximated by a multiplicative transfer function, $F_{\ell}$, that can fail to capture mode mixing and is dependent on the spectrum of the signal. To address these shortcomings, we have developed a simulation-based spectral correction approach that constructs a two-dimensional transfer matrix, $J_{\ell\ell'}$, which contains information about mode mixing in addition to mode attenuation. We demonstrate the application of this approach on data from the first flight of the SPIDER balloon-borne CMB experiment.
△ Less
Submitted 21 April, 2022; v1 submitted 1 November, 2021;
originally announced November 2021.
-
The XFaster Power Spectrum and Likelihood Estimator for the Analysis of Cosmic Microwave Background Maps
Authors:
A. E. Gambrel,
A. S. Rahlin,
X. Song,
C. R. Contaldi,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
N. N. Gandilo,
R. Gualtieri,
J. E. Gudmundsson,
M. Halpern
, et al. (42 additional authors not shown)
Abstract:
We present the XFaster analysis package. XFaster is a fast, iterative angular power spectrum estimator based on a diagonal approximation to the quadratic Fisher matrix estimator. XFaster uses Monte Carlo simulations to compute noise biases and filter transfer functions and is thus a hybrid of both Monte Carlo and quadratic estimator methods. In contrast to conventional pseudo-$C_\ell$ based method…
▽ More
We present the XFaster analysis package. XFaster is a fast, iterative angular power spectrum estimator based on a diagonal approximation to the quadratic Fisher matrix estimator. XFaster uses Monte Carlo simulations to compute noise biases and filter transfer functions and is thus a hybrid of both Monte Carlo and quadratic estimator methods. In contrast to conventional pseudo-$C_\ell$ based methods, the algorithm described here requires a minimal number of simulations, and does not require them to be precisely representative of the data to estimate accurate covariance matrices for the bandpowers. The formalism works with polarization-sensitive observations and also data sets with identical, partially overlapping, or independent survey regions. The method was first implemented for the analysis of BOOMERanG data, and also used as part of the Planck analysis. Here, we describe the full, publicly available analysis package, written in Python, as developed for the analysis of data from the 2015 flight of the SPIDER instrument. The package includes extensions for self-consistently estimating null spectra and for estimating fits for Galactic foreground contributions. We show results from the extensive validation of XFaster using simulations, and its application to the SPIDER data set.
△ Less
Submitted 24 May, 2021; v1 submitted 2 April, 2021;
originally announced April 2021.
-
A Constraint on Primordial $B$-Modes from the First Flight of the SPIDER Balloon-Borne Telescope
Authors:
SPIDER Collaboration,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
R. Gualtieri,
J. E. Gudmundsson
, et al. (46 additional authors not shown)
Abstract:
We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, an experiment designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. Results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency test…
▽ More
We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, an experiment designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. Results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency tests on these data. While the polarized CMB anisotropy from primordial density perturbations is the dominant signal in this region of sky, Galactic dust emission is also detected with high significance; Galactic synchrotron emission is found to be negligible in the SPIDER bands. We employ two independent foreground-removal techniques in order to explore the sensitivity of the cosmological result to the assumptions made by each. The primary method uses a dust template derived from Planck data to subtract the Galactic dust signal. A second approach, employing a joint analysis of SPIDER and Planck data in the harmonic domain, assumes a modified-blackbody model for the spectral energy distribution of the dust with no constraint on its spatial morphology. Using a likelihood that jointly samples the template amplitude and $r$ parameter space, we derive 95% upper limits on the primordial tensor-to-scalar ratio from Feldman-Cousins and Bayesian constructions, finding $r<0.11$ and $r<0.19$, respectively. Roughly half the uncertainty in $r$ derives from noise associated with the template subtraction. New data at 280 GHz from SPIDER's second flight will complement the Planck polarization maps, providing powerful measurements of the polarized Galactic dust emission.
△ Less
Submitted 24 March, 2021;
originally announced March 2021.
-
Design and pre-flight performance of SPIDER 280 GHz receivers
Authors:
E. C. Shaw,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. Austermann,
J. Beall,
D. T. Becker,
S. J. Benton,
A. S. Bergman,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S. Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway
, et al. (57 additional authors not shown)
Abstract:
In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for th…
▽ More
In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.
△ Less
Submitted 22 December, 2020;
originally announced December 2020.
-
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Authors:
B. Osherson,
J. P. Filippini,
J. Fu,
R. V. Gramillano,
R. Gualtieri,
E. C. Shaw,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
J. E. Gudmundsson,
M. Halpern,
J. Hartley,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (23 additional authors not shown)
Abstract:
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers…
▽ More
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
SPIDER: CMB polarimetry from the edge of space
Authors:
R. Gualtieri,
J. P. Filippini,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
R. V. Gramillano,
J. E. Gudmundsson
, et al. (39 additional authors not shown)
Abstract:
SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. SPIDER targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015 deployed a total…
▽ More
SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. SPIDER targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled Transition Edge Sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the SPIDER instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. SPIDER's second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
A New Limit on CMB Circular Polarization from SPIDER
Authors:
J. M. Nagy,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
J. E. Gudmundsson,
M. Halpern
, et al. (36 additional authors not shown)
Abstract:
We present a new upper limit on CMB circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the non-zero circular-to-linear polariz…
▽ More
We present a new upper limit on CMB circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the non-zero circular-to-linear polarization coupling of the HWP polarization modulators, data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes $V$ at 95 and 150 GHz from $33<\ell<307$. No other limits exist over this full range of angular scales, and SPIDER improves upon the previous limit by several orders of magnitude, providing 95% C.L. constraints on $\ell (\ell+1)C_{\ell}^{VV}/(2π)$ ranging from 141 $μK ^2$ to 255 $μK ^2$ at 150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments become increasingly sensitive, the techniques described in this paper can be applied to obtain even stronger constraints on circular polarization.
△ Less
Submitted 11 August, 2017; v1 submitted 1 April, 2017;
originally announced April 2017.
-
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
J. P. Filippini,
A. A. Fraisse,
A. Gambrel,
N. N. Gandilo,
M. Hasselfield,
M. Halpern,
G. C. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin,
W. C. Jones,
Z. Kermish,
C. J. MacTavish,
P. V. Mason
, et al. (18 additional authors not shown)
Abstract:
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he…
▽ More
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
△ Less
Submitted 11 September, 2015; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Pre-flight integration and characterization of the SPIDER balloon-borne telescope
Authors:
A. S. Rahlin,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. F. Hasselfield,
G. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (23 additional authors not shown)
Abstract:
We present the results of integration and characterization of the SPIDER instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne polarimeter designed to probe the primordial gravitational wave signal in the degree-scale $B$-mode polarization of the cosmic microwave background. With six independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz frequency bands, SP…
▽ More
We present the results of integration and characterization of the SPIDER instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne polarimeter designed to probe the primordial gravitational wave signal in the degree-scale $B$-mode polarization of the cosmic microwave background. With six independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz frequency bands, SPIDER will map 7.5% of the sky with a depth of 11 to 14 $μ$K$\cdot$arcmin at each frequency, which is a factor of $\sim$5 improvement over Planck. We discuss the integration of the pointing, cryogenic, electronics, and power sub-systems, as well as pre-flight characterization of the detectors and optical systems. SPIDER is well prepared for a December 2014 flight from Antarctica, and is expected to be limited by astrophysical foreground emission, and not instrumental sensitivity, over the survey region.
△ Less
Submitted 9 July, 2014;
originally announced July 2014.
-
Attitude determination for balloon-borne experiments
Authors:
N. N. Gandilo,
P. A. R. Ade,
M. Amiri,
F. E. Angile,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
M. J. Devlin,
B. Dober,
O. P. Dore,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
Y. Fukui,
N. Galitzki,
A. E. Gambrel,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield
, et al. (42 additional authors not shown)
Abstract:
An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitu…
▽ More
An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol flights from McMurdo Station, Antarctica, the system demonstrated an accuracy of <5' rms in-flight, and <5" rms post-flight.
△ Less
Submitted 15 July, 2014; v1 submitted 7 July, 2014;
originally announced July 2014.
-
BLASTbus electronics: general-purpose readout and control for balloon-borne experiments
Authors:
S. J. Benton,
P. A. Ade,
M. Amiri,
F. E. Angilè,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
M. J. Devlin,
B. Dober,
O. P. Doré,
C. D. Dowell,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
Y. Fukui,
N. Galitzki,
A. E. Gambrel,
N. N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Halpern
, et al. (44 additional authors not shown)
Abstract:
We present the second generation BLASTbus electronics. The primary purposes of this system are detector readout, attitude control, and cryogenic housekeeping, for balloon-borne telescopes. Readout of neutron transmutation doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition of hundreds of analog signals. Controlling a telescope's attitude requires the capability to inter…
▽ More
We present the second generation BLASTbus electronics. The primary purposes of this system are detector readout, attitude control, and cryogenic housekeeping, for balloon-borne telescopes. Readout of neutron transmutation doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition of hundreds of analog signals. Controlling a telescope's attitude requires the capability to interface to a wide variety of sensors and motors, and to use them together in a fast, closed loop. To achieve these different goals, the BLASTbus system employs a flexible motherboard-daughterboard architecture. The programmable motherboard features a digital signal processor (DSP) and field-programmable gate array (FPGA), as well as slots for three daughterboards. The daughterboards provide the interface to the outside world, with versions for analog to digital conversion, and optoisolated digital input/output. With the versatility afforded by this design, the BLASTbus also finds uses in cryogenic, thermometry, and power systems. For accurate timing control to tie everything together, the system operates in a fully synchronous manner. BLASTbus electronics have been successfully deployed to the South Pole, and flown on stratospheric balloons.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Authors:
J. D. Soler,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
C. Chiang,
C. C. Contaldi,
B. P. Crill,
O. P. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (22 additional authors not shown)
Abstract:
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in…
▽ More
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Pointing control for the SPIDER balloon-borne telescope
Authors:
Jamil A. Shariff,
Peter A. R. Ade,
Mandana Amiri,
Steven J. Benton,
Jamie J. Bock,
J. Richard Bond,
Sean A. Bryan,
H. Cynthia Chiang,
Carlo R. Contaldi,
Brendan P. Crill,
Olivier P. Doré,
Marzieh Farhang,
Jeffrey P. Filippini,
Laura M. Fissel,
Aurelien A. Fraisse,
Anne E. Gambrel,
Natalie N. Gandilo,
Sunil R. Golwala,
Jon E. Gudmundsson,
Mark Halpern,
Matthew Hasselfield,
Gene C. Hilton,
Warren A. Holmes,
Viktor V. Hristov,
Kent D. Irwin
, et al. (23 additional authors not shown)
Abstract:
We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI…
▽ More
We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation
Authors:
J. P. Kaufman,
N. J. Miller,
M. Shimon,
D. Barkats,
C. Bischoff,
I. Buder,
B. G. Keating,
J. M. Kovac,
P. A. R. Ade,
R. Aikin,
J. O. Battle,
E. M. Bierman,
J. J. Bock,
H. C. Chiang,
C. D. Dowell,
L. Duband,
J. Filippini,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
W. C. Jones,
S. S. Kernasovskiy,
C. L. Kuo,
E. M. Leitch,
P. V. Mason
, et al. (11 additional authors not shown)
Abstract:
Cosmic Microwave Background (CMB) polarimeters aspire to measure the faint $B$-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence which would produce non-zero expectation values for the CMB's $TB$ and $EB$ spectra. However, instrumental systematic effects can also cause these $TB$ and $EB$ correlations to be non-z…
▽ More
Cosmic Microwave Background (CMB) polarimeters aspire to measure the faint $B$-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence which would produce non-zero expectation values for the CMB's $TB$ and $EB$ spectra. However, instrumental systematic effects can also cause these $TB$ and $EB$ correlations to be non-zero. In particular, an overall miscalibration of the polarization orientation of the detectors produces $TB$ and $EB$ spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the $BB$ spectrum. The \bicep three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of $α= -2.77^\circ \pm 0.86^\circ \text{(statistical)} \pm 1.3^\circ \text{(systematic)}$. We revise the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We investigate the polarization rotation for the \bicep 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the $TB$ and $EB$ spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological $B$-mode spectrum from leaked $E$-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from $r<0.70$ to $r<0.65$ at $95\%$ confidence.
△ Less
Submitted 30 December, 2013;
originally announced December 2013.
-
Degree-Scale CMB Polarization Measurements from Three Years of BICEP1 Data
Authors:
BICEP1 Collaboration,
D. Barkats,
R. Aikin,
C. Bischoff,
I. Buder,
J. P. Kaufman,
B. G. Keating,
J. M. Kovac,
M. Su,
P. A. R. Ade,
J. O. Battle,
E. M. Bierman,
J. J. Bock,
H. C. Chiang,
C. D. Dowell,
L. Duband,
J. Filippini,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
W. C. Jones,
C. L. Kuo,
E. M. Leitch,
P. V. Mason,
T. Matsumura
, et al. (10 additional authors not shown)
Abstract:
BICEP1 is a millimeter-wavelength telescope designed specifically to measure the inflationary B-mode polarization of the Cosmic Microwave Background (CMB) at degree angular scales. We present results from an analysis of the data acquired during three seasons of observations at the South Pole (2006 to 2008). This work extends the two-year result published in Chiang et al. (2010), with additional da…
▽ More
BICEP1 is a millimeter-wavelength telescope designed specifically to measure the inflationary B-mode polarization of the Cosmic Microwave Background (CMB) at degree angular scales. We present results from an analysis of the data acquired during three seasons of observations at the South Pole (2006 to 2008). This work extends the two-year result published in Chiang et al. (2010), with additional data from the third season and relaxed detector-selection criteria. This analysis also introduces a more comprehensive estimation of band-power window functions, improved likelihood estimation methods and a new technique for deprojecting monopole temperature-to-polarization leakage which reduces this class of systematic uncertainty to a negligible level. We present maps of temperature, E- and B-mode polarization, and their associated angular power spectra. The improvement in the map noise level and polarization spectra error bars are consistent with the 52% increase in integration time relative to Chiang et al. (2010). We confirm both self-consistency of the polarization data and consistency with the two-year results. We measure the angular power spectra at 21 <= l <= 335 and find that the EE spectrum is consistent with Lambda Cold Dark Matter (LCDM) cosmology, with the first acoustic peak of the EE spectrum now detected at 15sigma. The BB spectrum remains consistent with zero. From B-modes only, we constrain the tensor-to-scalar ratio to r = 0.03+0.27-0.23, or r < 0.70 at 95% confidence level.
△ Less
Submitted 22 April, 2015; v1 submitted 4 October, 2013;
originally announced October 2013.
-
Scientific verification of Faraday Rotation Modulators: Detection of diffuse polarized Galactic emission
Authors:
S. Moyerman,
E. Bierman,
P. A. R. Ade,
R. Aiken,
D. Barkats,
C. Bischoff,
J. J. Bock,
H. C. Chiang,
C. D. Dowell,
L. Duband,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
W. C. Jones,
J. Kaufman,
B. G. Keating,
J. M. Kovac,
C. L. Kuo,
E. M. Leitch,
P. V. Mason,
T. Matsumura,
H. T. Nguyen,
N. Ponthieu,
C. Pryke,
S. Richter
, et al. (6 additional authors not shown)
Abstract:
The design and performance of a wide bandwidth linear polarization modulator based on the Faraday effect is described. Faraday Rotation Modulators (FRMs) are solid-state polarization switches that are capable of modulation up to ~10 kHz. Six FRMs were utilized during the 2006 observing season in the Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment; three FRMs were used at…
▽ More
The design and performance of a wide bandwidth linear polarization modulator based on the Faraday effect is described. Faraday Rotation Modulators (FRMs) are solid-state polarization switches that are capable of modulation up to ~10 kHz. Six FRMs were utilized during the 2006 observing season in the Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment; three FRMs were used at each of BICEP's 100 and 150 GHz frequency bands. The technology was verified through high signal-to-noise detection of Galactic polarization using two of the six FRMs during four observing runs in 2006. The features exhibit strong agreement with BICEP's measurements of the Galaxy using non-FRM pixels and with the Galactic polarization models. This marks the first detection of high signal-to-noise mm-wave celestial polarization using fast, active optical modulation. The performance of the FRMs during periods when they were not modulated was also analyzed and compared to results from BICEP's 43 pixels without FRMs.
△ Less
Submitted 17 February, 2013; v1 submitted 1 December, 2012;
originally announced December 2012.
-
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Authors:
A. A. Fraisse,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. Bryan,
B. Burger,
H. C. Chiang,
C. N. Clark,
C. R. Contaldi,
B. P. Crill,
G. Davis,
O. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (21 additional authors not shown)
Abstract:
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrum…
▽ More
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrument is significantly below the amplitude of an interesting cosmological signal with r=0.03. We present a scanning strategy that enables us to minimize uncertainty in the reconstruction of the Stokes parameters used to characterize the CMB, while accessing a relatively wide range of angular scales. Evaluating the amplitude of the polarized Galactic emission in the SPIDER field, we conclude that the polarized emission from interstellar dust is as bright or brighter than the cosmological signal at all SPIDER frequencies (90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the "Southern Hole." We show that two ~20-day flights of the SPIDER instrument can constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when foreground contamination is taken into account. In the absence of foregrounds, the same limit can be reached after one 20-day flight.
△ Less
Submitted 2 May, 2013; v1 submitted 15 June, 2011;
originally announced June 2011.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Design and performance of the Spider instrument
Authors:
M. C. Runyan,
P. A. R. Ade,
M. Amiri,
S. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Dore,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. Fissel,
N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
M. Halpern,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (18 additional authors not shown)
Abstract:
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architectu…
▽ More
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architecture, and magnetic shielding of the TES sensors and SQUID multiplexer. We also describe the optical, noise, and magnetic shielding performance of the 145 GHz prototype instrument insert.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Authors:
J. P. Filippini,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
B. Burger,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
M. Farhang,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (19 additional authors not shown)
Abstract:
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 28…
▽ More
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope modulates the polarization of incoming light to control systematics. Spider's first flight will be a 20-30-day Antarctic balloon campaign in December 2011. This flight will map \sim8% of the sky to achieve unprecedented sensitivity to the polarization signature of the gravitational wave background predicted by inflationary cosmology. The Spider mission will also serve as a proving ground for these detector technologies in preparation for a future satellite mission.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
A Millimeter-Wave Galactic Plane Survey With The BICEP Polarimeter
Authors:
E. M. Bierman,
T. Matsumura,
C. D. Dowell,
B. G. Keating,
P. Ade,
D. Barkats,
D. Barron,
J. O. Battle,
J. J. Bock,
H. C. Chiang,
T. L. Culverhouse,
L. Duband,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
J. P. Kaufman,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
E. M. Leitch,
P. V. Mason,
N. J. Miller,
H. T Nguyen,
C. Pryke,
S. Richter
, et al. (4 additional authors not shown)
Abstract:
In addition to its potential to probe the Inflationary cosmological paradigm, millimeter-wave polarimetry is a powerful tool for studying the Milky Way galaxy's composition and magnetic field structure. Towards this end, presented here are Stokes I, Q, and U maps of the Galactic plane from the millimeter-wave polarimeter BICEP covering the Galactic longitude range 260 - 340 degrees in three atmosp…
▽ More
In addition to its potential to probe the Inflationary cosmological paradigm, millimeter-wave polarimetry is a powerful tool for studying the Milky Way galaxy's composition and magnetic field structure. Towards this end, presented here are Stokes I, Q, and U maps of the Galactic plane from the millimeter-wave polarimeter BICEP covering the Galactic longitude range 260 - 340 degrees in three atmospheric transmission windows centered on 100, 150, and 220 GHz. The maps sample an optical depth 1 < AV < 30, and are consistent with previous characterizations of the Galactic millimeter-wave frequency spectrum and the large-scale magnetic field structure permeating the interstellar medium. Polarized emission is detected over the entire region within two degrees of the Galactic plane and indicates that the large-scale magnetic field is oriented parallel to the plane of the Galaxy. An observed trend of decreasing polarization fraction with increasing total intensity rules out the simplest model of a constant Galactic magnetic field throughout the Galaxy. Including WMAP data in the analysis, the degree-scale frequency spectrum of Galactic polarization fraction is plotted between 23 and 220 GHz for the first time. A generally increasing trend of polarization fraction with electromagnetic frequency is found, which varies from 0.5%-1.5%at frequencies below 50 GHz to 2.5%-3.5%above 90 GHz. The BICEP and WMAP data are fit to a two-component (synchrotron and dust) model showing that the higher frequency BICEP data are necessary to tightly constrain the amplitude and spectral index of Galactic dust. Furthermore, the dust amplitude predicted by this two-component fit is consistent with model predictions of dust emission in the BICEP bands.
△ Less
Submitted 4 March, 2011; v1 submitted 1 March, 2011;
originally announced March 2011.
-
Spider Optimization II: Optical, Magnetic and Foreground Effects
Authors:
D. T. O'Dea,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. Bryan,
B. Burger,
H. C. Chiang,
C. N. Clark,
C. R. Contaldi,
B. P. Crill,
G. Davis,
O. Dore,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
G. Hilton,
W. Holmes
, et al. (21 additional authors not shown)
Abstract:
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental s…
▽ More
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental systematic errors must be controlled with unprecedented accuracy. Here, we build on previous work to use simulations of Spider observations to examine the impact of several systematic effects that have been characterized through testing and modeling of various instrument components. In particular, we investigate the impact of the non-ideal spectral response of the half-wave plates, coupling between focal plane components and the Earth's magnetic field, and beam mismatches and asymmetries. We also present a model of diffuse polarized foreground emission based on a three-dimensional model of the Galactic magnetic field and dust, and study the interaction of this foreground emission with our observation strategy and instrumental effects. We find that the expected level of foreground and systematic contamination is sufficiently low for Spider to achieve its science goals.
△ Less
Submitted 2 February, 2011;
originally announced February 2011.
-
Absolute polarization angle calibration using polarized diffuse Galactic emission observed by BICEP
Authors:
Tomotake Matsumura,
Peter Ade,
Denis Barkats,
Darcy Barron,
John O. Battle,
Evan M. Bierman,
James J. Bock,
H. Cynthia Chiang,
Brendan P. Crill,
C. Darren Dowell,
Lionel Duband,
Eric F. Hivon,
William L. Holzapfel,
Viktor V. Hristov,
William C. Jones,
Brian G. Keating,
John M. Kovac,
Chao-Lin Kuo,
Andrew E. Lange,
Erik M. Leitch,
Peter V. Mason,
Hien T. Nguyen,
Nicolas Ponthieu,
Clem Pryke,
Steffen Richter
, et al. (3 additional authors not shown)
Abstract:
We present a method of cross-calibrating the polarization angle of a polarimeter using BICEP Galactic observations. \bicep\ was a ground based experiment using an array of 49 pairs of polarization sensitive bolometers observing from the geographic South Pole at 100 and 150 GHz. The BICEP polarimeter is calibrated to +/-0.01 in cross-polarization and less than +/-0.7 degrees in absolute polarizatio…
▽ More
We present a method of cross-calibrating the polarization angle of a polarimeter using BICEP Galactic observations. \bicep\ was a ground based experiment using an array of 49 pairs of polarization sensitive bolometers observing from the geographic South Pole at 100 and 150 GHz. The BICEP polarimeter is calibrated to +/-0.01 in cross-polarization and less than +/-0.7 degrees in absolute polarization orientation. BICEP observed the temperature and polarization of the Galactic plane (R.A= 100 degrees ~ 270 degrees and Dec. = -67 degrees ~ -48 degrees). We show that the statistical error in the 100 GHz BICEP Galaxy map can constrain the polarization angle offset of WMAP Wband to 0.6 degrees +\- 1.4 degrees. The expected 1 sigma errors on the polarization angle cross-calibration for Planck or EPIC are 1.3 degrees and 0.3 degrees at 100 and 150 GHz, respectively. We also discuss the expected improvement of the BICEP Galactic field observations with forthcoming BICEP2 and Keck observations.
△ Less
Submitted 16 July, 2010;
originally announced July 2010.
-
Characterization of the BICEP Telescope for High-Precision Cosmic Microwave Background Polarimetry
Authors:
Y. D. Takahashi,
P. A. R. Ade,
D. Barkats,
J. O. Battle,
E. M. Bierman,
J. J. Bock,
H. C. Chiang,
C. D. Dowell,
L. Duband,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
W. C. Jones,
B. G. Keating,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
E. M. Leitch,
P. V. Mason,
T. Matsumura,
H. T. Nguyen,
N. Ponthieu,
C. Pryke,
S. Richter,
G. Rocha
, et al. (1 additional authors not shown)
Abstract:
The BICEP experiment was designed specifically to search for the signature of inflationary gravitational waves in the polarization of the cosmic microwave background (CMB). Using a novel small-aperture refractor and 49 pairs of polarization-sensitive bolometers, BICEP has completed 3 years of successful observations at the South Pole beginning in 2006 February. To constrain the amplitude of the…
▽ More
The BICEP experiment was designed specifically to search for the signature of inflationary gravitational waves in the polarization of the cosmic microwave background (CMB). Using a novel small-aperture refractor and 49 pairs of polarization-sensitive bolometers, BICEP has completed 3 years of successful observations at the South Pole beginning in 2006 February. To constrain the amplitude of the inflationary B-mode polarization, which is expected to be at least 7 orders of magnitude fainter than the 3 K CMB intensity, precise control of systematic effects is essential. This paper describes the characterization of potential systematic errors for the BICEP experiment, supplementing a companion paper on the initial cosmological results. Using the analysis pipelines for the experiment, we have simulated the impact of systematic errors on the B-mode polarization measurement. Guided by these simulations, we have established benchmarks for the characterization of critical instrumental properties including bolometer relative gains, beam mismatch, polarization orientation, telescope pointing, sidelobes, thermal stability, and timestream noise model. A comparison of the benchmarks with the measured values shows that we have characterized the instrument adequately to ensure that systematic errors do not limit BICEP's 2-year results, and identifies which future refinements are likely necessary to probe inflationary B-mode polarization down to levels below a tensor-to-scalar ratio r = 0.1.
△ Less
Submitted 23 February, 2010; v1 submitted 22 June, 2009;
originally announced June 2009.
-
Measurement of Cosmic Microwave Background Polarization Power Spectra from Two Years of BICEP Data
Authors:
H. C. Chiang,
P. A. R. Ade,
D. Barkats,
J. O. Battle,
E. M. Bierman,
J. J. Bock,
C. D. Dowell,
L. Duband,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
W. C. Jones,
B. G. Keating,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
E. M. Leitch,
P. V. Mason,
T. Matsumura,
H. T. Nguyen,
N. Ponthieu,
C. Pryke,
S. Richter,
G. Rocha,
C. Sheehy
, et al. (3 additional authors not shown)
Abstract:
Background Imaging of Cosmic Extragalactic Polarization (BICEP) is a bolometric polarimeter designed to measure the inflationary B-mode polarization of the cosmic microwave background (CMB) at degree angular scales. During three seasons of observing at the South Pole (2006 through 2008), BICEP mapped ~2% of the sky chosen to be uniquely clean of polarized foreground emission. Here we present ini…
▽ More
Background Imaging of Cosmic Extragalactic Polarization (BICEP) is a bolometric polarimeter designed to measure the inflationary B-mode polarization of the cosmic microwave background (CMB) at degree angular scales. During three seasons of observing at the South Pole (2006 through 2008), BICEP mapped ~2% of the sky chosen to be uniquely clean of polarized foreground emission. Here we present initial results derived from a subset of the data acquired during the first two years. We present maps of temperature, Stokes Q and U, E and B modes, and associated angular power spectra. We demonstrate that the polarization data are self-consistent by performing a series of jackknife tests. We study potential systematic errors in detail and show that they are sub-dominant to the statistical errors. We measure the E-mode angular power spectrum with high precision at 21 < ell < 335, detecting for the first time the peak expected at ell ~ 140. The measured E-mode spectrum is consistent with expectations from a LCDM model, and the B-mode spectrum is consistent with zero. The tensor-to-scalar ratio derived from the B-mode spectrum is r = 0.03+0.31-0.26, or r < 0.72 at 95% confidence, the first meaningful constraint on the inflationary gravitational wave background to come directly from CMB B-mode polarization.
△ Less
Submitted 23 February, 2010; v1 submitted 5 June, 2009;
originally announced June 2009.
-
CMB polarimetry with BICEP: instrument characterization, calibration, and performance
Authors:
Yuki D. Takahashi,
Denis Barkats,
John O. Battle,
Evan M. Bierman,
James J. Bock,
H. Cynthia Chiang,
C. Darren Dowell,
Eric F. Hivon,
William L. Holzapfel,
Viktor V. Hristov,
William C. Jones,
J. P. Kaufman,
Brian G. Keating,
John M. Kovac,
Chao-Lin Kuo,
Andrew E. Lange,
Erik M. Leitch,
Peter V. Mason,
Tomotake Matsumura,
Hien T. Nguyen,
Nicolas Ponthieu,
Graca M. Rocha,
Ki Won Yoon,
P. Ade,
L. Duband
Abstract:
BICEP is a ground-based millimeter-wave bolometric array designed to target the primordial gravity wave signature on the polarization of the cosmic microwave background (CMB) at degree angular scales. Currently in its third year of operation at the South Pole, BICEP is measuring the CMB polarization with unprecedented sensitivity at 100 and 150 GHz in the cleanest available 2% of the sky, as wel…
▽ More
BICEP is a ground-based millimeter-wave bolometric array designed to target the primordial gravity wave signature on the polarization of the cosmic microwave background (CMB) at degree angular scales. Currently in its third year of operation at the South Pole, BICEP is measuring the CMB polarization with unprecedented sensitivity at 100 and 150 GHz in the cleanest available 2% of the sky, as well as deriving independent constraints on the diffuse polarized foregrounds with select observations on and off the Galactic plane. Instrument calibrations are discussed in the context of rigorous control of systematic errors, and the performance during the first two years of the experiment is reviewed.
△ Less
Submitted 12 August, 2008;
originally announced August 2008.
-
The Robinson Gravitational Wave Background Telescope (BICEP): a bolometric large angular scale CMB polarimeter
Authors:
K. W. Yoon,
P. A. R. Ade,
D. Barkats,
J. O. Battle,
E. M. Bierman,
J. J. Bock,
J. A. Brevik,
H. C. Chiang,
A. Crites,
C. D. Dowell,
L. Duband,
G. S. Griffin,
E. F. Hivon,
W. L. Holzapfel,
V. V. Hristov,
B. G. Keating,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
E. M. Leitch,
P. V. Mason,
H. T. Nguyen,
N. Ponthieu,
Y. D. Takahashi,
T. Renbarger
, et al. (2 additional authors not shown)
Abstract:
The Robinson Telescope (BICEP) is a ground-based millimeter-wave bolometric array designed to study the polarization of the cosmic microwave background radiation (CMB) and galactic foreground emission. Such measurements probe the energy scale of the inflationary epoch, tighten constraints on cosmological parameters, and verify our current understanding of CMB physics. Robinson consists of a 250-…
▽ More
The Robinson Telescope (BICEP) is a ground-based millimeter-wave bolometric array designed to study the polarization of the cosmic microwave background radiation (CMB) and galactic foreground emission. Such measurements probe the energy scale of the inflationary epoch, tighten constraints on cosmological parameters, and verify our current understanding of CMB physics. Robinson consists of a 250-mm aperture refractive telescope that provides an instantaneous field-of-view of 17 degrees with angular resolution of 55 and 37 arcminutes at 100 GHz and 150 GHz, respectively. Forty-nine pair of polarization-sensitive bolometers are cooled to 250 mK using a 4He/3He/3He sorption fridge system, and coupled to incoming radiation via corrugated feed horns. The all-refractive optics is cooled to 4 K to minimize polarization systematics and instrument loading. The fully steerable 3-axis mount is capable of continuous boresight rotation or azimuth scanning at speeds up to 5 deg/s. Robinson has begun its first season of observation at the South Pole. Given the measured performance of the instrument along with the excellent observing environment, Robinson will measure the E-mode polarization with high sensitivity, and probe for the B-modes to unprecedented depths. In this paper we discuss aspects of the instrument design and their scientific motivations, scanning and operational strategies, and the results of initial testing and observations.
△ Less
Submitted 12 June, 2006;
originally announced June 2006.
-
BOOMERANG: A Balloon-borne Millimeter Wave Telescope and Total Power Receiver for Mapping Anisotropy in the Cosmic Microwave Background
Authors:
B. P. Crill,
P. A. R. Ade,
D. R. Artusa,
R. S. Bhatia,
J. J. Bock,
A. Boscaleri,
P. Cardoni,
S. E. Church,
K. Coble,
P. deBernardis,
G. deTroia,
P. Farese,
K. M. Ganga,
M. Giacometti,
C. V. Haynes,
E. Hivon,
V. V. Hristov,
A. Iacoangeli,
W. C. Jones,
A. E. Lange,
L. Martinis,
S. Masi,
P. V. Mason,
P. D. Mauskopf,
L. Miglio
, et al. (12 additional authors not shown)
Abstract:
We describe BOOMERANG; a balloon-borne microwave telescope designed to map the Cosmic Microwave Background (CMB) at a resolution of 10' from the Long Duration Balloon (LDB) platform. The millimeter-wave receiver employs new technology in bolometers, readout electronics, cold re-imaging optics, millimeter-wave filters, and cryogenics to obtain high sensitivity to CMB anisotropy. Sixteen detectors…
▽ More
We describe BOOMERANG; a balloon-borne microwave telescope designed to map the Cosmic Microwave Background (CMB) at a resolution of 10' from the Long Duration Balloon (LDB) platform. The millimeter-wave receiver employs new technology in bolometers, readout electronics, cold re-imaging optics, millimeter-wave filters, and cryogenics to obtain high sensitivity to CMB anisotropy. Sixteen detectors observe in 4 spectral bands centered at 90, 150, 240 and 410 GHz. The wide frequency coverage, the long duration flight, the optical design and the observing strategy provide strong rejection of systematic effects. We report the flight performance of the instrument during a 10.5 day stratospheric balloon flight launched from McMurdo Station, Antarctica that mapped ~2000 square degrees of the sky.
△ Less
Submitted 13 December, 2002; v1 submitted 14 June, 2002;
originally announced June 2002.
-
The Polatron: A Millimeter-Wave Cosmic Microwave Background Polarimeter for the OVRO 5.5 m Telescope
Authors:
B. J. Philhour,
B. G. Keating,
P. A. R. Ade,
R. S. Bhatia,
J. J. Bock,
S. E. Church,
J. Glenn,
J. R. Hinderks,
V. V. Hristov,
W. C. Jones,
M. Kamionkowski,
D. E. Kumar,
A. E. Lange,
J. R. Leong,
D. P. Marrone,
B. S. Mason,
P. V. Mason,
M. M. Shuman,
G. I. Sirbi
Abstract:
We describe the development of a bolometric receiver designed to measure the arcminute-scale polarization of the cosmic microwave background (CMB). The Polatron will be mounted at the Cassegrain focus of the 5.5 m telescope at the Owens Valley Radio Observatory (OVRO). The receiver will measure both the Q and U Stokes parameters over a 20% pass-band centered near 100 GHz, with the input polariza…
▽ More
We describe the development of a bolometric receiver designed to measure the arcminute-scale polarization of the cosmic microwave background (CMB). The Polatron will be mounted at the Cassegrain focus of the 5.5 m telescope at the Owens Valley Radio Observatory (OVRO). The receiver will measure both the Q and U Stokes parameters over a 20% pass-band centered near 100 GHz, with the input polarization signal modulated at ~0.6 Hz by a rotating, birefringent, quartz half-wave plate. In six months of observation we plan to observe ~400 2.5 arcminute pixels in a ring about the North Celestial Pole to a precision of ~6 μK/pixel in each of Q and U, adequate to unambiguously detect CMB polarization at levels predicted by current models.
△ Less
Submitted 28 June, 2001;
originally announced June 2001.
-
BOOMERanG: a scanning telescope for 10 arcminutes resolution CMB maps
Authors:
S. Masi,
P. A. R. Ade,
R. Artusa,
J. J. Bock,
A. Boscaleri,
B. P. Crill,
P. de Bernardis,
G. De Troia,
P. C. Farese,
M. Giacometti,
V. V. Hristov,
A. Iacoangeli,
A. E. Lange,
A. T. Lee,
L. Martinis,
P. V. Mason,
P. D. Mauskopf,
F. Melchiorri,
L. Miglio,
T. Montroy,
C. B. Netterfield,
E. Pascale,
F. Piacentini,
P. L. Richards,
G. Romeo
, et al. (2 additional authors not shown)
Abstract:
The BOOMERanG experiment is a stratospheric balloon telescope intended to measure the Cosmic Microwave Background anisotropy at angular scales between a few degrees and ten arcminutes. The experiment features a wide focal plane with 16 detectors in the frequency bands centered at 90, 150, 220, 400 GHz, with FWHM ranging between 18 and 10 arcmin. It will be flown on a long duration (7-14 days) fl…
▽ More
The BOOMERanG experiment is a stratospheric balloon telescope intended to measure the Cosmic Microwave Background anisotropy at angular scales between a few degrees and ten arcminutes. The experiment features a wide focal plane with 16 detectors in the frequency bands centered at 90, 150, 220, 400 GHz, with FWHM ranging between 18 and 10 arcmin. It will be flown on a long duration (7-14 days) flight circumnavigating Antarctica at the end of 1998. The instrument was flown with a reduced focal plane (6 detectors, 90 and 150 GHz bands, 25 to 15 arcmin FWHM) on a qualification flight from Texas, in August 1997. A wide (~300 sq. deg, i.e. about 5000 independent beams at 150 GHz) sky area was mapped in the constellations of Capricornus, Aquarius, Cetus, with very low foreground contamination. The instrument was calibrated using the CMB dipole and observations of Jupiter. The LDB version of the instrument has been qualified and shipped to Antarctica.
△ Less
Submitted 30 November, 1999;
originally announced November 1999.
-
Mapping the CMB Sky: The BOOMERANG experiment
Authors:
P. de Bernardis,
P. A. R. Ade,
R. Artusa,
J. J. Bock,
A. Boscaleri,
B. P. Crill,
G. De Troia,
P. C. Farese,
M. Giacommetti,
V. V. Hristov,
A. Iacoangeli,
A. E. Lange,
A. T. Lee,
S. Masi,
L. Martinis,
P. V. Mason,
P. D. Mauskopf,
F. Melchiorri,
L. Miglio,
T. Montroy,
C. B. Netterfield,
E. Pascale,
F. Piacentini,
P. L. Richards,
J. E. Ruhl
, et al. (1 additional authors not shown)
Abstract:
We describe the BOOMERanG experiment, a stratospheric balloon telescope intended to measure the Cosmic Microwave Background anisotropy at angular scales between a few degrees and ten arcminutes. The experiment has been optimized for a long duration (7 to 14 days) flight circumnavigating Antarctica at the end of 1998. A test flight was performed on Aug.30, 1997 in Texas. The level of performance…
▽ More
We describe the BOOMERanG experiment, a stratospheric balloon telescope intended to measure the Cosmic Microwave Background anisotropy at angular scales between a few degrees and ten arcminutes. The experiment has been optimized for a long duration (7 to 14 days) flight circumnavigating Antarctica at the end of 1998. A test flight was performed on Aug.30, 1997 in Texas. The level of performance achieved in the test flight was satisfactory and compatible with the requirements for the long duration flight.
△ Less
Submitted 24 November, 1999;
originally announced November 1999.