Neutron phase filtering for separating phase- and attenuation signal in aluminium and anodic aluminium oxide
Authors:
Estrid Buhl Naver,
Okan Yetik,
Noémie Ott,
Matteo Busi,
Pavel Trtik,
Luise Theil Kuhn,
Markus Strobl
Abstract:
Neutron imaging has gained significant importance as a material characterisation technique and is particularly useful to visualise hydrogenous materials in objects opaque to other radiations. Particular fields of application include investigations of hydrogen in metals as well as metal corrosion, thanks to the fact that neutrons can penetrate metals better than e.g. X-rays and are at the same time…
▽ More
Neutron imaging has gained significant importance as a material characterisation technique and is particularly useful to visualise hydrogenous materials in objects opaque to other radiations. Particular fields of application include investigations of hydrogen in metals as well as metal corrosion, thanks to the fact that neutrons can penetrate metals better than e.g. X-rays and are at the same time highly sensitive to hydrogen. However at interfaces for example those that are prone to corrosion, refraction effects sometimes obscure the attenuation image, which is used to for hydrogen quantification. Refraction, as a differential phase effect, diverts the neutron beam away from the interface in the image which leads to intensity gain and intensity loss regions, which are superimposed to the attenuation image, thus obscuring the interface region and hindering quantitative analyses of e.g. hydrogen content in the vicinity of the interface or in an oxide layer. For corresponding effects in X-ray imaging, a phase filter approach was developed and is generally based on transport-of-intensity considerations. Here, we compare such an approach, that has been adapted to neutrons, with another simulation-based assessment using the ray-tracing software McStas. The latter appears superior and promising for future extensions which enable fitting forward models via simulations in order to separate phase and attenuation effects and thus pave the way for overcoming quantitative limitations at refracting interfaces.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
Polychromatic neutron phase contrast imaging of weakly absorbing samples enabled by phase retrieval
Authors:
Maja Østergaard,
Estrid Buhl Naver,
Anders Kaestner,
Peter K. Willendrup,
Annemarie Brüel,
Henning Osholm Sørensen,
Jesper Skovhus Thomsen,
Søren Schmidt,
Henning Friis Poulsen,
Luise Theil Kuhn,
Henrik Birkedal
Abstract:
We demonstrate the use of a phase retrieval technique for propagation-based phase contrast neutron imaging with a polychromatic beam. This enables imaging samples with low absorption contrast and/or improving the signal-to-noise ratio to facilitate e.g. time resolved measurements. A metal sample, designed to be close to a pure phase object, and a bone sample with canals partially filled with D2O w…
▽ More
We demonstrate the use of a phase retrieval technique for propagation-based phase contrast neutron imaging with a polychromatic beam. This enables imaging samples with low absorption contrast and/or improving the signal-to-noise ratio to facilitate e.g. time resolved measurements. A metal sample, designed to be close to a pure phase object, and a bone sample with canals partially filled with D2O were used for demonstrating the technique. These samples were imaged with a polychromatic neutron beam followed by phase retrieval. For both samples the signal-to-noise ratio were significantly improved and in case of the bone sample, the phase retrieval allowed for separation of bone and D2O, which is important for example for in situ flow experiments. The use of deuteration-contrast avoids the use of chemical contrast enhancement and makes neutron imaging an interesting complementary method to X-ray imaging of bone.
△ Less
Submitted 4 October, 2022;
originally announced October 2022.