-
Penning-trap measurement of the $Q$-value of the electron capture in $^{163}\mathrm{Ho}$ for the determination of the electron neutrino mass
Authors:
Christoph Schweiger,
Martin Braß,
Vincent Debierre,
Menno Door,
Holger Dorrer,
Christoph E. Düllmann,
Christian Enss,
Pavel Filianin,
Loredana Gastaldo,
Zoltán Harman,
Maurits W. Haverkort,
Jost Herkenhoff,
Paul Indelicato,
Christoph H. Keitel,
Kathrin Kromer,
Daniel Lange,
Yuri N. Novikov,
Dennis Renisch,
Alexander Rischka,
Rima X. Schüssler,
Sergey Eliseev,
Klaus Blaum
Abstract:
The investigation of the absolute scale of the effective neutrino mass remains challenging due to the exclusively weak interaction of neutrinos with all known particles in the standard model of particle physics. Currently, the most precise and least model-dependent upper limit on the electron antineutrino mass is set by the KATRIN experiment from the analysis of the tritium \b{eta}-decay. Another…
▽ More
The investigation of the absolute scale of the effective neutrino mass remains challenging due to the exclusively weak interaction of neutrinos with all known particles in the standard model of particle physics. Currently, the most precise and least model-dependent upper limit on the electron antineutrino mass is set by the KATRIN experiment from the analysis of the tritium \b{eta}-decay. Another promising approach is the electron capture in $^{163}\mathrm{Ho}$, which is under investigation using microcalorimetry within the ECHo and HOLMES collab orations. An independently measured Q-value of this process is vital for the assessment of systematic uncertainties in the neutrino mass determination. Here, we report a direct, independent determination of this $Q$-value by measuring the free-space cyclotron frequency ratio of highly charged ions of $^{163}\mathrm{Ho}$ and $^{163}\mathrm{Dy}$ in the Penning trap experiment \textsc{Pentatrap}. Combining this ratio with atomic physics calculations of the electronic binding energies yields a $Q$-value of $2863.2(0.6)\,\mathrm{eV}/c^{2}$ - a more than 50-fold improvement over the state-of-the-art. This will enable the determination of the electron neutrino mass on a sub-eV level from the analysis of the electron capture in $^{163}\mathrm{Ho}$.
△ Less
Submitted 9 February, 2024;
originally announced February 2024.
-
Direct WIMP detection rates for transitions in isomeric nuclei
Authors:
M. V Smirnov,
G. Yang,
Yu. N. Novikov,
J. D. Vergados,
D. Bonatsos
Abstract:
The direct detection of dark matter constituents, in particular the weakly interacting massive particles (WIMPs), is central to particle physics and cosmology. In this paper we study WIMP induced transitions from isomeric nuclear states for two possible isomeric candidates: $\rm^{180}Ta$ and $\rm^{166}Ho$. The experimental setup, which can measure the possible decay of $\rm^{180}Ta$ induced by WIM…
▽ More
The direct detection of dark matter constituents, in particular the weakly interacting massive particles (WIMPs), is central to particle physics and cosmology. In this paper we study WIMP induced transitions from isomeric nuclear states for two possible isomeric candidates: $\rm^{180}Ta$ and $\rm^{166}Ho$. The experimental setup, which can measure the possible decay of $\rm^{180}Ta$ induced by WIMPs, was proposed. The corresponding estimates of the half-life of $\rm^{180}Ta$ are given in the sense that the WIMP-nucleon interaction can be interpreted as ordinary radioactive decay.
△ Less
Submitted 20 June, 2024; v1 submitted 26 January, 2024;
originally announced January 2024.
-
Observation of a low-lying metastable electronic state in highly charged lead by Penning-trap mass spectrometry
Authors:
Kathrin Kromer,
Chunhai Lyu,
Menno Door,
Pavel Filianin,
Zoltán Harman,
Jost Herkenhoff,
Paul Indelicato,
Christoph H. Keitel,
Daniel Lange,
Yuri N. Novikov,
Christoph Schweiger,
Sergey Eliseev,
Klaus Blaum
Abstract:
Highly charged ions (HCIs) offer many opportunities for next-generation clock research due to the vast landscape of available electronic transitions in different charge states. The development of XUV frequency combs has enabled the search for clock transitions based on shorter wavelengths in HCIs. However, without initial knowledge of the energy of the clock states, these narrow transitions are di…
▽ More
Highly charged ions (HCIs) offer many opportunities for next-generation clock research due to the vast landscape of available electronic transitions in different charge states. The development of XUV frequency combs has enabled the search for clock transitions based on shorter wavelengths in HCIs. However, without initial knowledge of the energy of the clock states, these narrow transitions are difficult to be probed by lasers. In this Letter, we provide experimental observation and theoretical calculation of a long-lived electronic state in Nb-like Pb$^{41+}$ which could be used as a clock state. With the mass spectrometer Pentatrap, the excitation energy of this metastable state is directly determined as a mass difference at an energy of 31.2(8) eV, corresponding to one of the most precise relative mass determinations to date with a fractional uncertainty of $4\times10^{-12}$. This experimental result agrees within 1 $σ$ with two partially different \textit{ab initio} multi-configuration Dirac-Hartree-Fock calculations of 31.68(13) eV and 31.76(35) eV, respectively. With a calculated lifetime of 26.5(5.3) days, the transition from this metastable state to the ground state bears a quality factor of $1.1\times10^{23}$ and allows for the construction of a HCI clock with a fractional frequency instability of $<10^{-19}/\sqrtτ$.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
High-precision determination of $g$ factors and masses of $^{20}\text{Ne}^{9+}$ and $^{22}\text{Ne}^{9+}$
Authors:
F. Heiße,
M. Door,
T. Sailer,
P. Filianin,
J. Herkenhoff,
C. M. König,
K. Kromer,
D. Lange,
J. Morgner,
A. Rischka,
Ch. Schweiger,
B. Tu.,
Y. N. Novikov,
S. Eliseev,
S. Sturm,
K. Blaum
Abstract:
We present the measurements of individual bound electron $g$ factors of $^{20}\text{Ne}^{9+}$ and $^{22}\text{Ne}^{9+}$ on the relative level of $0.1\,\text{parts}$ per billion. The comparison with theory represents the most stringent test of bound-state QED in strong electric fields. A dedicated mass measurement results in $m\left(^{20}\text{Ne}\right)=19.992\,440\,168\,77\,(9)\,\text{u}$, which…
▽ More
We present the measurements of individual bound electron $g$ factors of $^{20}\text{Ne}^{9+}$ and $^{22}\text{Ne}^{9+}$ on the relative level of $0.1\,\text{parts}$ per billion. The comparison with theory represents the most stringent test of bound-state QED in strong electric fields. A dedicated mass measurement results in $m\left(^{20}\text{Ne}\right)=19.992\,440\,168\,77\,(9)\,\text{u}$, which improves the current literature value by a factor of nineteen, disagrees by $4$ standard deviations and represents the most precisely measured mass value in atomic mass units. Together, these measurements yield an electron mass on the relative level of $0.1\,\text{ppb}$ with $m_{\text{e}}=5.485\,799\,090\,99\,(59) \times 10^{-4}\,\text{u}$ as well as a factor of eight improved $m\left(^{22}\text{Ne}\right)=21.991\,385\,098\,2\,(26)\,\text{u}$.
△ Less
Submitted 17 October, 2023;
originally announced October 2023.
-
High-precision mass measurement of doubly magic $^{208}$Pb
Authors:
Kathrin Kromer,
Chunhai Lyu,
Menno Door,
Pavel Filianin,
Zoltán Harman,
Jost Herkenhoff,
Wenjia Huang,
Christoph H. Keitel,
Daniel Lange,
Yuri N. Novikov,
Christoph Schweiger,
Sergey Eliseev,
Klaus Blaum
Abstract:
The absolute atomic mass of $^{208}$Pb has been determined with a fractional uncertainty of $7\times 10^{-11}$ by measuring the cyclotron-frequency ratio $R$ of $^{208}$Pb$^{41+}$ to $^{132}$Xe$^{26+}$ with the high-precision Penning-trap mass spectrometer Pentatrap and computing the binding energies $E_{\text{Pb}}$ and $E_{\text{Xe}}$ of the missing 41 and 26 atomic electrons, respectively, with…
▽ More
The absolute atomic mass of $^{208}$Pb has been determined with a fractional uncertainty of $7\times 10^{-11}$ by measuring the cyclotron-frequency ratio $R$ of $^{208}$Pb$^{41+}$ to $^{132}$Xe$^{26+}$ with the high-precision Penning-trap mass spectrometer Pentatrap and computing the binding energies $E_{\text{Pb}}$ and $E_{\text{Xe}}$ of the missing 41 and 26 atomic electrons, respectively, with the ab initio fully relativistic multi-configuration Dirac-Hartree-Fock (MCDHF) method. $R$ has been measured with a relative precision of $9\times 10^{-12}$. $E_{\text{Pb}}$ and $E_{\text{Xe}}$ have been computed with an uncertainty of 9.1 eV and 2.1 eV, respectively, yielding $207.976\,650\,571(14)$ u (u$=9.314\,941\,024\,2(28)\times 10^{8}$ eV/c$^2$) for the $^{208}$Pb neutral atomic mass. This result agrees within $1.2σ$ with that from the Atomic-Mass Evaluation (AME) 2020, while improving the precision by almost two orders of magnitude. The new mass value directly improves the mass precision of 14 nuclides in the region of Z=81-84 and is the most precise mass value with A>200. Thus, the measurement establishes a new region of reference mass values which can be used e.g. for precision mass determination of transuranium nuclides, including the superheavies.
△ Less
Submitted 20 October, 2022;
originally announced October 2022.
-
Direct determination of the excitation energy of quasi-stable isomer $^{180m}$Ta
Authors:
D. A. Nesterenko,
K. Blaum,
P. Delahaye,
S. Eliseev,
T. Eronen,
P. Filianin,
Z. Ge,
M. Hukkanen,
A. Kankainen,
Yu. N. Novikov,
A. V. Popov,
A. Raggio,
M. Stryjczyk,
V. Virtanen
Abstract:
$^{180m}…
▽ More
$^{180m}$Ta is a naturally abundant quasi-stable nuclide and the longest-lived nuclear isomer known to date. It is of interest for, among others, the search for dark matter, for the development of a gamma laser and for astrophysics. So far, its excitation energy has not been measured directly but has been based on an evaluation of available nuclear reaction data. We have determined the excitation energy of this isomer with high accuracy using the Penning-trap mass spectrometer JYFLTRAP. The determined mass difference between the ground and isomeric states of $^{180}$Ta yields an excitation energy of 76.79(55) keV for $^{180m}$Ta. This is the first direct measurement of the excitation energy and provides a better accuracy than the previous evaluation value, 75.3(14) keV.
△ Less
Submitted 21 May, 2022;
originally announced May 2022.
-
Mass-difference measurements on heavy nuclides with at an eV/c2 accuracy level with PENTATRAP
Authors:
A. Rischka,
H. Cakir,
M. Door,
P. Filianin,
Z. Harman,
W. J. Huang,
P. Indelicato,
C. H. Keitel,
C. M. Koenig,
K. Kromer,
M. Mueller,
Y. N. Novikov,
R. X. Schuessler,
Ch. Schweiger,
S. Eliseev,
K. Blaum
Abstract:
First ever measurements of the ratios of free cyclotron frequencies of heavy highly charged ions with Z>50 with relative uncertainties close to 1e-11 are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon…
▽ More
First ever measurements of the ratios of free cyclotron frequencies of heavy highly charged ions with Z>50 with relative uncertainties close to 1e-11 are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon isotopes, ranging from 126Xe to 134Xe, have been determined. Moreover, the first direct measurement of an electron binding energy in a heavy highly charged ion, namely of the 37th atomic electron in xenon, with an uncertainty of a few eV is demonstrated. The obtained value agrees with the calculated one using two independent different implementations of the multiconfiguration Dirac-Hartree-Fock method. PENTATRAP opens the door to future measurements of electron binding energies in highly charged heavy ions for more stringent tests of bound-state quantum electrodynamics in strong electromagnetic fields and for an investigation of the manifestation of Light Dark Matter in isotopic chains of certain chemical elements.
△ Less
Submitted 17 March, 2022;
originally announced March 2022.
-
$\text{Direct}~Q\text{-Value Determination of the}~β^-~\text{Decay of} ~^{187}\text{Re}$
Authors:
P. Filianin,
C. Lyu,
M. Door,
K. Blaum,
W. J. Huang,
M. Haverkort,
P. Indelicato,
C. H. Keitel,
K. Kromer,
D. Lange,
Y. N. Novikov,
A. Rischka,
R. X. Schüssler,
Ch. Schweiger,
S. Sturm,
S. Ulmer,
Z. Harman,
S. Eliseev
Abstract:
The cyclotron frequency ratio of $^{187}\mathrm{Os}^{29+}$ to $^{187}\mathrm{Re}^{29+}$ ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of $R=1.000\:000\:013\:882(5)$ is to date the most precise such measurement performed on ions. Furthermore, the total binding-energy difference of the 29 missing electrons in Re and Os was calculated by relativistic multico…
▽ More
The cyclotron frequency ratio of $^{187}\mathrm{Os}^{29+}$ to $^{187}\mathrm{Re}^{29+}$ ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of $R=1.000\:000\:013\:882(5)$ is to date the most precise such measurement performed on ions. Furthermore, the total binding-energy difference of the 29 missing electrons in Re and Os was calculated by relativistic multiconfiguration methods, yielding the value of $ΔE = 53.5(10)$ eV. Finally, using the achieved results, the mass difference between neutral $^{187}$Re and $^{187}$Os, i.e., the $Q$ value of the $β^-$ decay of $^{187}$Re, is determined to be 2470.9(13) eV.
△ Less
Submitted 16 August, 2021;
originally announced August 2021.
-
Neutrinoless Double-Electron Capture
Authors:
K. Blaum,
S. Eliseev,
F. A. Danevich,
V. I. Tretyak,
Sergey Kovalenko,
M. I. Krivoruchenko,
Yu. N. Novikov,
J. Suhonen
Abstract:
Double-beta processes play a key role in the exploration of neutrino and weak interaction properties, and in the searches for effects beyond the Standard Model. During the last half century many attempts were undertaken to search for double-beta decay with emission of two electrons, especially for its neutrinoless mode ($0\nu2β^-$), the latter being still not observed. Double-electron capture (2EC…
▽ More
Double-beta processes play a key role in the exploration of neutrino and weak interaction properties, and in the searches for effects beyond the Standard Model. During the last half century many attempts were undertaken to search for double-beta decay with emission of two electrons, especially for its neutrinoless mode ($0\nu2β^-$), the latter being still not observed. Double-electron capture (2EC) was not in focus so far because of its in general lower transition probability. However, the rate of neutrinoless double-electron capture ($0\nu2$EC) can experience a resonance enhancement by many orders of magnitude in case the initial and final states are energetically degenerate. In the resonant case, the sensitivity of the $0\nu2$EC process can approach the sensitivity of the $0\nu2β^-$ decay in the search for the Majorana mass of neutrinos, right-handed currents, and other new physics. We present an overview of the main experimental and theoretical results obtained during the last decade in this field. The experimental part outlines search results of 2EC processes and measurements of the decay energies for possible resonant $0ν$2EC transitions. An unprecedented precision in the determination of decay energies with Penning traps has allowed one to refine the values of the degeneracy parameter for all previously known near-resonant decays and has reduced the rather large uncertainties in the estimate of the $0\nu2$EC half-lives. The theoretical part contains an updated analysis of the electron shell effects and an overview of the nuclear structure models, in which the nuclear matrix elements of the $0\nu2$EC decays are calculated. One can conclude that the decay probability of $0ν$2EC can experience a significant enhancement in several nuclides.
△ Less
Submitted 29 July, 2020;
originally announced July 2020.
-
Detection of metastable electronic states by Penning trap mass spectrometry
Authors:
Rima Xenia Schüssler,
Hendrik Bekker,
Martin Braß,
Halil Cakir,
José R. Crespo López-Urrutia,
Menno Door,
Pavel Filianin,
Zoltan Harman,
Maurits W. Haverkort,
Wen Jia Huang,
Paul Indelicato,
Christoph Helmut Keitel,
Charlotte Maria König,
Kathrin Kromer,
Marius Müller,
Yuri N. Novikov,
Alexander Rischka,
Christoph Schweiger,
Sven Sturm,
Stefan Ulmer,
Ssergey Eliseev,
Klaus Blaum
Abstract:
State-of-the-art optical clocks achieve fractional precisions of $10^{-18}$ and below using ensembles of atoms in optical lattices or individual ions in radio-frequency traps. Promising candidates for novel clocks are highly charged ions (HCIs) and nuclear transitions, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range, now becoming accessible to…
▽ More
State-of-the-art optical clocks achieve fractional precisions of $10^{-18}$ and below using ensembles of atoms in optical lattices or individual ions in radio-frequency traps. Promising candidates for novel clocks are highly charged ions (HCIs) and nuclear transitions, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range, now becoming accessible to frequency combs. However, insufficiently accurate atomic structure calculations still hinder the identification of suitable transitions in HCIs. Here, we report on the discovery of a long-lived metastable electronic state in a HCI by measuring the mass difference of the ground and the excited state in Re, the first non-destructive, direct determination of an electronic excitation energy. This result agrees with our advanced calculations, and we confirmed them with an Os ion with the same electronic configuration. We used the high-precision Penning-trap mass spectrometer PENTATRAP, unique in its synchronous use of five individual traps for simultaneous mass measurements. The cyclotron frequency ratio $R$ of the ion in the ground state to the metastable state could be determined to a precision of $δR=1\cdot 10^{-11}$, unprecedented in the heavy atom regime. With a lifetime of about 130 days, the potential soft x-ray frequency reference at $ν=4.86\cdot 10^{16}\,\text{Hz}$ has a linewidth of only $Δν\approx 5\cdot 10^{-8}\,\text{Hz}$, and one of the highest electronic quality factor ($Q=\fracν{Δν}\approx 10^{24}$) ever seen in an experiment. Our low uncertainty enables searching for more HCI soft x-ray clock transitions, needed for promising precision studies of fundamental physics in a thus far unexplored frontier.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
Sterile neutrino oscillometry with Jinping
Authors:
M. V. Smirnov,
Zh. J. Hu,
J. J. Ling,
Yu. N. Novikov,
Z. Wang,
G. Yang
Abstract:
The existence of sterile neutrino is an open question in neutrino physics up to now. The method of neutrino oscillometry provides a powerful tool to test the common 3+1 sterile neutrino hypothesis, i.e. three active flavors and one sterile falvor. There are several antineutrino sources can be used for this method. One of them is the well known isotope chain of $^{144}{\rm Ce}-$$^{144}{\rm Pr}$ wit…
▽ More
The existence of sterile neutrino is an open question in neutrino physics up to now. The method of neutrino oscillometry provides a powerful tool to test the common 3+1 sterile neutrino hypothesis, i.e. three active flavors and one sterile falvor. There are several antineutrino sources can be used for this method. One of them is the well known isotope chain of $^{144}{\rm Ce}-$$^{144}{\rm Pr}$ with initial activity around 50-100 kCi. It has compact size and might be installed either outside or inside the detector. Another one is the short-lived isotope $\rm^8Li$, which can be produced in nuclear reaction of a proton beam hitting beryllium target. The Lithium source has only the out-of-detector option due to its large size. The proposed Jinping water-based liquid scintillator detector will be used as a detection volume. Above experimental setups will allow us to cover the current best fit values of oscillation parameters with 90% C.L. At the same time, it is sensitive to the region of Neutrino-4 result.
△ Less
Submitted 12 February, 2020;
originally announced February 2020.
-
Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology
Authors:
D. A. Nesterenko,
S. Eliseev,
K. Blaum,
M. Block,
S. Chenmarev,
A. Doerr,
C. Droese,
P. E. Filianin,
M. Goncharov,
E. Minaya Ramirez,
Yu. N. Novikov,
L. Schweikhard,
V. V. Simon
Abstract:
For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discre…
▽ More
For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discrepancy with older proportional counter measurements. This is essential for the determination of the neutrino mass from the beta-decay of 187Re as planned in future microcalorimetric measurements. In addition, an accurate mass difference of 187Re and 187Os is also important for the assessment of 187Re for cosmochronology.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination
Authors:
S. Eliseev,
K. Blaum,
M. Block,
S. Chenmarev,
H. Dorrer,
Ch. E. Duellmann,
C. Enss,
P. E. Filianin,
L. Gastaldo,
M. Goncharov,
U. Koester,
F. Lautenschlaeger,
Yu. N. Novikov,
A. Rischka,
R. X. Schuessler,
L. Schweikhard,
A. Tuerler
Abstract:
The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q…
▽ More
The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.
△ Less
Submitted 14 April, 2016;
originally announced April 2016.
-
A search for neutrino-antineutrino mass inequality by means of sterile neutrino oscillometry
Authors:
M. V. Smirnov,
K. K. Loo,
Yu. N. Novikov,
W. H. Trzaska,
M. Wurm
Abstract:
The investigation of the oscillation pattern induced by the sterile neutrinos might determine the oscillation parameters, and at the same time, allow to probe CPT symmetry in the leptonic sector through neutrino-antineutrino mass inequality. We propose to use a large scintillation detector like JUNO or LENA to detect electron neutrinos and electron antineutrinos from MCi electron capture or beta d…
▽ More
The investigation of the oscillation pattern induced by the sterile neutrinos might determine the oscillation parameters, and at the same time, allow to probe CPT symmetry in the leptonic sector through neutrino-antineutrino mass inequality. We propose to use a large scintillation detector like JUNO or LENA to detect electron neutrinos and electron antineutrinos from MCi electron capture or beta decay sources. Our calculations indicate that such an experiment is realistic and could be performed in parallel to the current research plans for JUNO and RENO. Requiring at least 5$σ$ confidence level and assuming the values of the oscillation parameters indicated by the current global fit, we would be able to detect neutrino-antineutrino mass inequality of the order of 0.5% or larger, which would imply a signal of CPT anomalies.
△ Less
Submitted 17 July, 2015; v1 submitted 11 May, 2015;
originally announced May 2015.
-
Direct mapping of nuclear shell effects in the heaviest elements
Authors:
E. Minaya Ramirez,
D. Ackermann,
K. Blaum,
M. Block,
C. Droese,
Ch. E. Düllmann,
M. Dworschak,
M. Eibach,
S. Eliseev,
E. Haettner,
F. Herfurth,
F. P. Heßberger,
S. Hofmann,
J. Ketelaer,
G. Marx,
M. Mazzocco,
D. Nesterenko,
Yu. N. Novikov,
W. R. Plaß,
D. Rodríguez,
C. Scheidenberger,
L. Schweikhard,
P. G. Thirolf,
C. Weber
Abstract:
Quantum-mechanical shell effects are expected to strongly enhance nuclear binding on an "island of stability" of superheavy elements. The predicted center at proton number $Z=114,120$, or $126$ and neutron number $N=184$ has been substantiated by the recent synthesis of new elements up to $Z=118$. However the location of the center and the extension of the island of stability remain vague. High-pr…
▽ More
Quantum-mechanical shell effects are expected to strongly enhance nuclear binding on an "island of stability" of superheavy elements. The predicted center at proton number $Z=114,120$, or $126$ and neutron number $N=184$ has been substantiated by the recent synthesis of new elements up to $Z=118$. However the location of the center and the extension of the island of stability remain vague. High-precision mass spectrometry allows the direct measurement of nuclear binding energies and thus the determination of the strength of shell effects. Here, we present such measurements for nobelium and lawrencium isotopes, which also pin down the deformed shell gap at $N=152$.
△ Less
Submitted 25 June, 2014;
originally announced June 2014.
-
On the keV sterile neutrino search in electron capture
Authors:
P. E. Filianin,
K. Blaum,
S. A. Eliseev,
L. Gastaldo,
Yu. N. Novikov,
V. M. Shabaev,
I. I. Tupitsyn,
J. Vergados
Abstract:
A joint effort of cryogenic microcalorimetry (CM) and high-precision Penning-trap mass spectrometry (PT-MS) in investigating atomic orbital electron capture (EC) can shed light on the possible existence of heavy sterile neutrinos with masses from 0.5 to 100 keV. Sterile neutrinos are expected to perturb the shape of the atomic de-excitation spectrum measured by CM after a capture of the atomic orb…
▽ More
A joint effort of cryogenic microcalorimetry (CM) and high-precision Penning-trap mass spectrometry (PT-MS) in investigating atomic orbital electron capture (EC) can shed light on the possible existence of heavy sterile neutrinos with masses from 0.5 to 100 keV. Sterile neutrinos are expected to perturb the shape of the atomic de-excitation spectrum measured by CM after a capture of the atomic orbital electrons by a nucleus. This effect should be observable in the ratios of the capture probabilities from different orbits. The sensitivity of the ratio values to the contribution of sterile neutrinos strongly depends on how accurately the mass difference between the parent and the daughter nuclides of EC-transitions can be measured by, e.g., PT-MS. A comparison of such probability ratios in different isotopes of a certain chemical element allows one to exclude many systematic uncertainties and thus could make feasible a determination of the contribution of sterile neutrinos on a level below 1%. Several electron capture transitions suitable for such measurements are discussed.
△ Less
Submitted 18 February, 2014;
originally announced February 2014.
-
Prospects of detection of relic antineutrinos by resonant absorption in electron capturing nuclei
Authors:
J. D. Vergados,
Yu. N. Novikov
Abstract:
We consider the possibility of detecting relic anti-neutrinos by their resonant absorption in a nucleus, which can undergo electron capture. This possibility appears quite realistic in view of recent developments in Penning Trap Mass Spectrometry and cryogenic micro-calorimetry.
We consider the possibility of detecting relic anti-neutrinos by their resonant absorption in a nucleus, which can undergo electron capture. This possibility appears quite realistic in view of recent developments in Penning Trap Mass Spectrometry and cryogenic micro-calorimetry.
△ Less
Submitted 25 September, 2014; v1 submitted 3 December, 2013;
originally announced December 2013.
-
The Electron Capture $^{163}$Ho Experiment ECHo: an overview
Authors:
L. Gastaldo,
K. Blaum,
A. Doerr,
Ch. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
Amand Faessler,
A. Fleischmann,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay or electron capture of suitable nuclides can provide information on the electron neutrino mass value. We present the Electron Capture $^{163}$Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following electron capture of $^{163}$Ho. A high precision and high statistics spectrum will be measured with arrays of metallic magnetic calorimeters. We discuss some of the essential aspects of ECHo to reach the proposed sensitivity: detector optimization and performance, multiplexed readout, $^{163}$Ho source production and purification, as well as a precise theoretical and experimental parameterization of the calorimetric EC spectrum including in particular the value of $Q_{\mathrm{EC}}$. We present preliminary results obtained with a first prototype of single channel detectors as well as a first 64-pixel chip with integrated micro-wave SQUID multiplexer, which will already allow to investigate $m(ν_{\mathrm{e}})$ in the eV range.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
-
The Electron Capture $^{163}$Ho Experiment ECHo
Authors:
K. Blaum,
A. Doerr,
C. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
A. Faessler,
A. Fleischmann,
L. Gastaldo,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In t…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In this talk we present the Electron Capture 163-Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following the electron capture process of 163-Ho. A high precision and high statistics spectrum will be measured by means of low temperature magnetic calorimeter arrays. We present preliminary results obtained with a first prototype of single channel detectors as well as the participating groups and their on-going developments.
△ Less
Submitted 11 June, 2013;
originally announced June 2013.
-
Probing the nuclide 180W for neutrinoless double-electron capture exploration
Authors:
C. Droese,
K. Blaum,
M. Block,
S. Eliseev,
F. Herfurth,
E. Minaya Ramirez,
Yu. N. Novikov,
L. Schweikhard,
V. M. Shabaev,
I. I. Tupitsyn,
S. Wycech,
K. Zuber,
N. A. Zubova
Abstract:
The mass difference of the nuclides 180W and 180Hf has been measured with the Penning-trap mass spectrometer SHIPTRAP to investigate 180W as a possible candidate for the search for neutrinoless doubleelectron capture. The Q-value was measured to 143.20(27)keV. This value in combination with the calculations of the atomic electron wave functions and other parameters results in a half-life of the 0+…
▽ More
The mass difference of the nuclides 180W and 180Hf has been measured with the Penning-trap mass spectrometer SHIPTRAP to investigate 180W as a possible candidate for the search for neutrinoless doubleelectron capture. The Q-value was measured to 143.20(27)keV. This value in combination with the calculations of the atomic electron wave functions and other parameters results in a half-life of the 0+ \rightarrow 0+ ground-state to ground-state double-electron capture transition of approximately 5\cdot10E27 years/<m_ee[eV]>^2.
△ Less
Submitted 28 November, 2011;
originally announced November 2011.
-
Neutrino oscillometry at the next generation neutrino observatory
Authors:
Yu. N. Novikov,
T. Enqvist,
A. N. Erykalov,
F. v. Feilitzsch,
J. Hissa,
K. Loo,
D. A. Nesterenko,
L. Oberauer,
F. Thorne,
W. Trzaska,
J. D. Vergados,
M. Wurm
Abstract:
The large next generation liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) offers an excellent opportunity for neutrino oscillometry. The characteristic spatial pattern of very low monoenergetic neutrino disappearance from artificial radioactive sources can be detected within the long length of detector. Sufficiently strong sources of more than 1 MCi activity can be produced at nu…
▽ More
The large next generation liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) offers an excellent opportunity for neutrino oscillometry. The characteristic spatial pattern of very low monoenergetic neutrino disappearance from artificial radioactive sources can be detected within the long length of detector. Sufficiently strong sources of more than 1 MCi activity can be produced at nuclear reactors. Oscillometry will provide a unique tool for precise determination of the mixing parameters for both active and sterile neutrinos within the broad mass region 0.01 - 2 (eV)^2. LENA can be considered as a versatile tool for a careful investigation of neutrino oscillations.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
PENTATRAP: A novel cryogenic multi-Penning trap experiment for high-precision mass measurements on highly charged ions
Authors:
J. Repp,
Ch. Böhm,
J. R. Crespo López-Urrutia,
A. Dörr,
S. Eliseev,
S. George,
M. Goncharov,
Yu. N. Novikov,
C. Roux,
S. Sturm,
S. Ulmer,
K. Blaum
Abstract:
The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino ph…
▽ More
The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino physics, stringent tests of quantum electrodynamics in the regime of extreme electric fields, and a test of special relativity. Main features of PENTATRAP are an access to a source of highly charged ions, a multi-trap configuration, simultaneous measurements of frequencies, a continuous precise monitoring of magnetic field fluctuations, a fast exchange between different ions, and a highly sensitive cryogenic non-destructive detection system. This paper gives a motivation for the new mass spectrometer PENTATRAP, presents its experimental setup, and describes the present status.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
On the search of sterile neutrinos by oscillometry measurements
Authors:
J. D. Vergados,
Y. Giomataris,
Yu. N. Novikov
Abstract:
It is shown that the "new" neutrino with a high mass squared difference and a small mixing angle should reveal itself in the oscillometry measurements. For a judicious monochromatic neutrino source the "new" oscillation length $L_{42}$ is expected shorter than 1.5 m. Thus the needed measurements can be implemented with a gaseous spherical TPC of modest dimensions with a very good energy and positi…
▽ More
It is shown that the "new" neutrino with a high mass squared difference and a small mixing angle should reveal itself in the oscillometry measurements. For a judicious monochromatic neutrino source the "new" oscillation length $L_{42}$ is expected shorter than 1.5 m. Thus the needed measurements can be implemented with a gaseous spherical TPC of modest dimensions with a very good energy and position resolution. The best candidates for oscillometry are discussed and the sensitivity to the mixing angle $θ_{14}$ has been estimated: $\sin^2{(2θ_{14})}$=0.05 (99{%}) for two months of data handling with $^{51}$Cr.
△ Less
Submitted 18 May, 2011;
originally announced May 2011.
-
The next-generation liquid-scintillator neutrino observatory LENA
Authors:
Michael Wurm,
John F. Beacom,
Leonid B. Bezrukov,
Daniel Bick,
Johannes Blümer,
Sandhya Choubey,
Christian Ciemniak,
Davide D'Angelo,
Basudeb Dasgupta,
Amol Dighe,
Grigorij Domogatsky,
Steve Dye,
Sergey Eliseev,
Timo Enqvist,
Alexey Erykalov,
Franz von Feilitzsch,
Gianni Fiorentini,
Tobias Fischer,
Marianne Göger-Neff,
Peter Grabmayr,
Caren Hagner,
Dominikus Hellgartner,
Johannes Hissa,
Shunsaku Horiuchi,
Hans-Thomas Janka
, et al. (52 additional authors not shown)
Abstract:
We propose the liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) as a next-generation neutrino observatory on the scale of 50 kt. The outstanding successes of the Borexino and KamLAND experiments demonstrate the large potential of liquid-scintillator detectors in low-energy neutrino physics. LENA's physics objectives comprise the observation of astrophysical and terrestrial neutrin…
▽ More
We propose the liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) as a next-generation neutrino observatory on the scale of 50 kt. The outstanding successes of the Borexino and KamLAND experiments demonstrate the large potential of liquid-scintillator detectors in low-energy neutrino physics. LENA's physics objectives comprise the observation of astrophysical and terrestrial neutrino sources as well as the investigation of neutrino oscillations. In the GeV energy range, the search for proton decay and long-baseline neutrino oscillation experiments complement the low-energy program. Based on the considerable expertise present in European and international research groups, the technical design is sufficiently mature to allow for an early start of detector realization.
△ Less
Submitted 2 March, 2012; v1 submitted 29 April, 2011;
originally announced April 2011.
-
Mass measurements of very neutron-deficient Mo and Tc isotopes and their impact on rp process nucleosynthesis
Authors:
E. Haettner,
D. Ackermann,
G. Audi,
K. Blaum,
M. Block,
S. Eliseev,
T. Fleckenstein,
F. Herfurth,
F. P. Heßberger,
S. Hofmann,
J. Ketelaer,
J. Ketter,
H. -J. Kluge,
G. Marx,
M. Mazzocco,
Yu. N. Novikov,
W. R. Plaß,
S. Rahaman,
T. Rauscher,
D. Rodríguez,
H. Schatz,
C. Scheidenberger,
L. Schweikhard,
B. Sun,
P. G. Thirolf
, et al. (3 additional authors not shown)
Abstract:
The masses of ten proton-rich nuclides, including the N=Z+1 nuclides 85-Mo and 87-Tc, were measured with the Penning trap mass spectrometer SHIPTRAP. Compared to the Atomic Mass Evaluation 2003 a systematic shift of the mass surface by up to 1.6 MeV is observed causing significant abundance changes of the ashes of astrophysical X-ray bursts. Surprisingly low alpha-separation energies for neutron-d…
▽ More
The masses of ten proton-rich nuclides, including the N=Z+1 nuclides 85-Mo and 87-Tc, were measured with the Penning trap mass spectrometer SHIPTRAP. Compared to the Atomic Mass Evaluation 2003 a systematic shift of the mass surface by up to 1.6 MeV is observed causing significant abundance changes of the ashes of astrophysical X-ray bursts. Surprisingly low alpha-separation energies for neutron-deficient Mo and Tc are found, making the formation of a ZrNb cycle in the rp process possible. Such a cycle would impose an upper temperature limit for the synthesis of elements beyond Nb in the rp process.
△ Less
Submitted 28 March, 2011;
originally announced March 2011.
-
Probing the fourth neutrino existence by neutral current oscillometry in the spherical gaseous TPC
Authors:
J. D. Vergados,
Y. Giomataris,
Yu. N. Novikov
Abstract:
It is shown that, if the "new neutrino" implied by the Reactor Neutrino Anomaly exists and is in fact characterized by the suggested relatively high mass squared difference and reasonably large mixing angle, it should clearly reveal itself in the oscillometry measurements. For a judicious neutrino source the "new oscillation length L14 is expected shorter than 3m. Thus the needed measurements can…
▽ More
It is shown that, if the "new neutrino" implied by the Reactor Neutrino Anomaly exists and is in fact characterized by the suggested relatively high mass squared difference and reasonably large mixing angle, it should clearly reveal itself in the oscillometry measurements. For a judicious neutrino source the "new oscillation length L14 is expected shorter than 3m. Thus the needed measurements can be implemented with a gaseous spherical TPC of modest dimensions with a very good energy and position resolution, detecting nuclear recoils following the coherent neutrino-nucleus elastic scattering. The best candidates for oscillometry, yielding both monochromatic neutrinos as well as antineutrinos, are discussed. A sensitivity in the mixing angle theta14, (sin(2\theta14))^2=0.1 (99 %), can be reached after a few months of data handling.
△ Less
Submitted 29 March, 2011; v1 submitted 28 March, 2011;
originally announced March 2011.
-
Neutrino Oscillometry
Authors:
J. D. Vergados,
Y. Giomataris,
Yu. N. Novikov
Abstract:
Neutrino oscillations are studied employing sources of low energy monoenergetic neutrinos following electron capture by the nucleus and measuring electron recoils. Since the neutrino energy is very low the oscillation length appearing in this electronic neutrino disappearance experiment can be so small that the full oscillation can take place inside the detector. Thus one may determine very accura…
▽ More
Neutrino oscillations are studied employing sources of low energy monoenergetic neutrinos following electron capture by the nucleus and measuring electron recoils. Since the neutrino energy is very low the oscillation length appearing in this electronic neutrino disappearance experiment can be so small that the full oscillation can take place inside the detector. Thus one may determine very accurately all the neutrino oscillation parameters. In particular one can measure or set a better limit on the unknown parameter theta13. One, however, has to pay the price that the expected counting rates are very small. Thus one needs a very intensive neutrino source and a large detector with as low as possible energy threshold and high energy and position resolution. Both spherical gaseous and cylindrical liquid detectors are studied. Different source candidates are considered
△ Less
Submitted 21 October, 2010;
originally announced October 2010.
-
Exploring new features of neutrino oscillations with very low energy monoenergetic neutrinos
Authors:
J. D. Vergados,
Yu. N. Novikov
Abstract:
In the present work we propose to study neutrino oscillations employing sources of monoenergetic neutrinos following electron capture by the nucleus. Since the neutrino energy is very low the smaller of the two oscillation lengths, L23, appearing in this electronic neutrino disappearance experiment can be so small that the full oscillation can take place inside the detector and one may determine v…
▽ More
In the present work we propose to study neutrino oscillations employing sources of monoenergetic neutrinos following electron capture by the nucleus. Since the neutrino energy is very low the smaller of the two oscillation lengths, L23, appearing in this electronic neutrino disappearance experiment can be so small that the full oscillation can take place inside the detector and one may determine very accurately the neutrino oscillation parameters.
Since in this case the oscillation probability is proportional to theta13, one can measure or set a better limit on the unknown parameter theta13. This is quite important, since, if this mixing angle vanishes, there is not going to be CP violation in the leptonic sector. The best way to detect it is by measuring electron recoils in neutrino-electron scattering. One, however, has to pay the price that the expected counting rates are very small. Thus one needs a very intensive neutrino source and a large detector with as low as possible energy threshold and high energy and position resolution. Both spherical gaseous and cylindrical liquid detectors are studied. Different source candidates are considered.
△ Less
Submitted 26 July, 2010; v1 submitted 19 June, 2010;
originally announced June 2010.
-
Penning traps as a versatile tool for precise experiments in fundamental physics
Authors:
K. Blaum,
Yu. N. Novikov,
G. Werth
Abstract:
This review article describes the trapping of charged particles. The main principles of electromagnetic confinement of various species from elementary particles to heavy atoms are briefly described. The preparation and manipulation with trapped single particles, as well as methods of frequency measurements, providing unprecedented precision, are discussed. Unique applications of Penning traps in…
▽ More
This review article describes the trapping of charged particles. The main principles of electromagnetic confinement of various species from elementary particles to heavy atoms are briefly described. The preparation and manipulation with trapped single particles, as well as methods of frequency measurements, providing unprecedented precision, are discussed. Unique applications of Penning traps in fundamental physics are presented. Ultra-precise trap-measurements of masses and magnetic moments of elementary particles (electrons, positrons, protons and antiprotons) confirm CPT-conservation, and allow accurate determination of the fine-structure constant alpha and other fundamental constants. This together with the information on the unitarity of the quark-mixing matrix, derived from the trap-measurements of atomic masses, serves for assessment of the Standard Model of the physics world. Direct mass measurements of nuclides targeted to some advanced problems of astrophysics and nuclear physics are also presented.
△ Less
Submitted 6 September, 2009;
originally announced September 2009.
-
Mass measurements in the vicinity of the rp-process and the nu p-process paths with JYFLTRAP and SHIPTRAP
Authors:
C. Weber,
V. -V. Elomaa,
R. Ferrer,
C. Fröhlich,
D. Ackermann,
J. Äystö,
G. Audi,
L. Batist,
K. Blaum,
M. Block,
A. Chaudhuri,
M. Dworschak,
S. Eliseev,
T. Eronen,
U. Hager,
J. Hakala,
F. Herfurth,
F. P. Heßberger,
S. Hofmann,
A. Jokinen,
A. Kankainen,
H. -J. Kluge,
K. Langanke,
A. Martín,
G. Martínez-Pinedo
, et al. (20 additional authors not shown)
Abstract:
The masses of very neutron-deficient nuclides close to the astrophysical rp- and nu p-process paths have been determined with the Penning trap facilities JYFLTRAP at JYFL/Jyväskylä and SHIPTRAP at GSI/Darmstadt. Isotopes from yttrium (Z = 39) to palladium (Z = 46) have been produced in heavy-ion fusion-evaporation reactions. In total 21 nuclides were studied and almost half of the mass values we…
▽ More
The masses of very neutron-deficient nuclides close to the astrophysical rp- and nu p-process paths have been determined with the Penning trap facilities JYFLTRAP at JYFL/Jyväskylä and SHIPTRAP at GSI/Darmstadt. Isotopes from yttrium (Z = 39) to palladium (Z = 46) have been produced in heavy-ion fusion-evaporation reactions. In total 21 nuclides were studied and almost half of the mass values were experimentally determined for the first time: 88Tc, 90-92Ru, 92-94Rh, and 94,95Pd. For the 95Pdm, (21/2^+) high-spin state, a first direct mass determination was performed. Relative mass uncertainties of typically $δm / m = 5 \times 10^{-8}$ were obtained. The impact of the new mass values has been studied in nu p-process nucleosynthesis calculations. The resulting reaction flow and the final abundances are compared to those obtained with the data of the Atomic Mass Evaluation 2003.
△ Less
Submitted 29 August, 2008;
originally announced August 2008.
-
Mass Measurements and Implications for the Energy of the High-Spin Isomer in 94Ag
Authors:
A. Kankainen,
V. -V. Elomaa,
L. Batist,
S. Eliseev,
T. Eronen,
U. Hager,
J. Hakala,
A. Jokinen,
I. D. Moore,
Yu. N. Novikov,
H. Penttilä,
A. Popov,
S. Rahaman,
S. Rinta-Antila,
J. Rissanen,
A. Saastamoinen,
D. M. Seliverstov,
T. Sonoda,
G. Vorobjev,
C. Weber,
J. Äystö
Abstract:
Nuclides in the vicinity of 94Ag have been studied with the Penning trap mass spectrometer JYFLTRAP at the Ion-Guide Separator On-Line. The masses of the two-proton-decay daughter 92Rh and the beta-decay daughter 94Pd of the high-spin isomer in 94Ag have been measured, and the masses of 93Pd and 94Ag have been deduced. When combined with the data from the one-proton or two-proton-decay experimen…
▽ More
Nuclides in the vicinity of 94Ag have been studied with the Penning trap mass spectrometer JYFLTRAP at the Ion-Guide Separator On-Line. The masses of the two-proton-decay daughter 92Rh and the beta-decay daughter 94Pd of the high-spin isomer in 94Ag have been measured, and the masses of 93Pd and 94Ag have been deduced. When combined with the data from the one-proton or two-proton-decay experiments, the results lead to contradictory mass excess values for the high-spin isomer in 94Ag, -46370(170) or -44970(100) keV, corresponding to excitation energies of 6960(400) or 8360(370) keV, respectively.
△ Less
Submitted 9 October, 2008; v1 submitted 30 April, 2008;
originally announced April 2008.
-
Isospin Dependence in the Odd-Even Staggering of Nuclear Binding Energies
Authors:
Yu. A. Litvinov,
T. J. Buervenich,
H. Geissel,
Yu. N. Novikov,
Z. Patyk,
C. Scheidenberger,
F. Attallah,
G. Audi,
K. Beckert,
F. Bosch,
M. Falch,
B. Franzke,
M. Hausmann,
Th. Kerscher,
O. Klepper,
H. -J. Kluge,
C. Kozhuharov,
K. E. G. Loebner,
D. G. Madland,
J. A. Maruhn,
G. Muenzenberg,
F. Nolden,
T. Radon,
M. Steck,
S. Typel
, et al. (1 additional authors not shown)
Abstract:
The FRS-ESR facility at GSI provides unique conditions for precision measurements of large areas on the nuclear mass surface in a single experiment. Values for masses of 604 neutron-deficient nuclides (30<=Z<=92) were obtained with a typical uncertainty of 30 microunits. The masses of 114 nuclides were determined for the first time. The odd-even staggering (OES) of nuclear masses was systematica…
▽ More
The FRS-ESR facility at GSI provides unique conditions for precision measurements of large areas on the nuclear mass surface in a single experiment. Values for masses of 604 neutron-deficient nuclides (30<=Z<=92) were obtained with a typical uncertainty of 30 microunits. The masses of 114 nuclides were determined for the first time. The odd-even staggering (OES) of nuclear masses was systematically investigated for isotopic chains between the proton shell closures at Z=50 and Z=82. The results were compared with predictions of modern nuclear models. The comparison revealed that the measured trend of OES is not reproduced by the theories fitted to masses only. The spectral pairing gaps extracted from models adjusted to both masses, and density related observables of nuclei agree better with the experimental data.
△ Less
Submitted 2 August, 2005;
originally announced August 2005.
-
Memory Effect in Silicon Nitride in Silicon Devices
Authors:
V. A. Gritsenko,
Yu. N. Morokov,
Yu. N. Novikov,
J. B. Xu
Abstract:
The dominant dielectric used currently in silicon devices is silicon oxide. Its application for future devices will be impeded by several fundamental limitations which lead to low reliability of semiconductor devices and to the necessity of alternative dielectrics. Amorphous silicon nitride and oxynitride are considered now as alternative to silicon oxide in future devices. One of the unique pro…
▽ More
The dominant dielectric used currently in silicon devices is silicon oxide. Its application for future devices will be impeded by several fundamental limitations which lead to low reliability of semiconductor devices and to the necessity of alternative dielectrics. Amorphous silicon nitride and oxynitride are considered now as alternative to silicon oxide in future devices. One of the unique property of amorphous silicon nitride is the electron and hole capture by the deep traps with extremely long life time (10 years) in the captured state (the memory effect). This property is employed in memory devices and microprocessors in computers. Despite numerous efforts the nature of traps responsible for the memory effect in this material is so far unclear. In this paper we discuss the nature of such traps using the quantum-chemical simulation. The calculations show that the defects responsible for the electron and hole capture in amorphous silicon nitride can be the Si-Si defects created by excess silicon atoms.
△ Less
Submitted 25 November, 2000;
originally announced November 2000.
-
Nature of traps responsible for failure of MOS devices
Authors:
V. A. Gritsenko,
P. M. Lenahan,
Yu. N. Morokov,
Yu. N. Novikov
Abstract:
A failure of chips in a huge amount of modern electronic devices is connected as a rule with the undesirable capturing of charge (electrons and holes) by traps in a thin insulating film of silicon oxide in transistors. It leads to a breakdown of transistors or to a destructive change of their characteristics. It is suggested that silicon oxide will be replaced in the next generation of nanoscale…
▽ More
A failure of chips in a huge amount of modern electronic devices is connected as a rule with the undesirable capturing of charge (electrons and holes) by traps in a thin insulating film of silicon oxide in transistors. It leads to a breakdown of transistors or to a destructive change of their characteristics. It is suggested that silicon oxide will be replaced in the next generation of nanoscale devices by silicon oxynitride. Therefore, it is very important to understand the nature of traps in this material. We discuss this nature using the quantum-chemical simulation.
△ Less
Submitted 14 November, 2000;
originally announced November 2000.