-
Understanding and exploiting interfacial interactions between phosphonic acid functional groups and co-evaporated perovskites
Authors:
Thomas Feeney,
Julian Petry,
Abderrezak Torche,
Dirk Hauschild,
Benjamin Hacene,
Constantin Wansorra,
Alexander Diercks,
Michelle Ernst,
Lothar Weinhardt,
Clemens Heske,
Ganna Grynova,
Ulrich W. Paetzold,
Paul Fassl
Abstract:
Interfacial engineering has fueled recent development of p-i-n perovskite solar cells (PSCs), with self-assembled monolayer-based hole-transport layers (SAM-HTLs) enabling almost lossless contacts for solution-processed PSCs, resulting in the highest achieved power conversion efficiency (PCE) to date. Substrate interfaces are particularly crucial for the growth and quality of co-evaporated PSCs. H…
▽ More
Interfacial engineering has fueled recent development of p-i-n perovskite solar cells (PSCs), with self-assembled monolayer-based hole-transport layers (SAM-HTLs) enabling almost lossless contacts for solution-processed PSCs, resulting in the highest achieved power conversion efficiency (PCE) to date. Substrate interfaces are particularly crucial for the growth and quality of co-evaporated PSCs. However, adoption of SAM-HTLs for co-evaporated perovskite absorbers is complicated by the underexplored interaction of such perovskites with phosphonic acid functional groups. In this work, we highlight how exposed phosphonic acid functional groups impact the initial phase and final bulk crystal structures of co-evaporated perovskites and their resultant PCE. The explored surface interaction is mediated by hydrogen bonding with interfacial iodine, leading to increased formamidinium iodide adsorption, persistent changes in perovskite structure, and stabilization of bulk α-FAPbI3, hypothesized as being due to kinetic trapping. Our results highlight the potential of exploiting substrates to increase control of co-evaporated perovskite growth.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
On the Formation of Hydrogen Peroxide in Water Microdroplets
Authors:
Adair Gallo Jr.,
Nayara H. Musskopf,
Xinlei Liu,
Ziqiang Yang,
Jeferson Petry,
Peng Zhang,
Sigurdur Thoroddsen,
Hong Im,
Himanshu Mishra
Abstract:
Recent reports on the formation of hydrogen peroxide (H$_2$O$_2$) in water microdroplets produced via pneumatic spraying or capillary condensation have garnered significant attention. How covalent bonds in water could break under such conditions challenges our textbook understanding of physical chemistry and the water substance. While there is no definitive answer, it has been speculated that ultr…
▽ More
Recent reports on the formation of hydrogen peroxide (H$_2$O$_2$) in water microdroplets produced via pneumatic spraying or capillary condensation have garnered significant attention. How covalent bonds in water could break under such conditions challenges our textbook understanding of physical chemistry and the water substance. While there is no definitive answer, it has been speculated that ultrahigh electric fields at the air-water interface are responsible for this chemical transformation. Here, we resolve this mystery via a comprehensive experimental investigation of H$_2$O$_2$ formation in (i) water microdroplets sprayed over a range of liquid flow-rates, the (shearing) air flow rates, and the air composition (ii) water microdroplets condensed on hydrophobic substrates formed via hot water or humidifier under controlled air composition. Specifically, we assessed the contributions of the evaporative concentration and shock waves in sprays and the effects of trace O$_3$(g) on the H$_2$O$_2$ formation. Glovebox experiments revealed that the H$_2$O$_2$ formation in water microdroplets was most sensitive to the air-borne ozone (O$_3$) concentration. In the absence of O$_3$(g), we could not detect H$_2$O$_2$(aq) in sprays or condensates (detection limit: 250 nM. In contrast, microdroplets exposed to atmospherically relevant O$_3$(g) concentration (10-100 ppb) formed 2-30 $μ$M H$_2$O$_2$(aq); increasing the gas-liquid surface area, mixing, and contact duration increased H$_2$O$_2$(aq) concentration. Thus, the mystery is resolved - the water surface facilitates the O$_3$(g) mass transfer, which is followed by the chemical transformation of O$_3$(aq) into H$_2$O$_2$(aq). These findings should also help us understand the implications of this chemistry in natural and applied contexts.
△ Less
Submitted 14 October, 2021;
originally announced October 2021.
-
The air-water interface of condensed water microdroplets does not produce H$_2$O$_2$
Authors:
Nayara H. Musskopf,
Adair Gallo Jr.,
Peng Zhang,
Jeferson Petry,
Himanshu Mishra
Abstract:
Recent reports on the production of hydrogen peroxide (H$_2$O$_2$) on the surface of condensed water microdroplets without the addition of catalysts or additives have sparked significant interest. The underlying mechanism is speculated to be ultrahigh electric fields at the air-water interface; smaller droplets present higher interfacial area and produce higher (detectable) H$_2$O$_2$ yields. Here…
▽ More
Recent reports on the production of hydrogen peroxide (H$_2$O$_2$) on the surface of condensed water microdroplets without the addition of catalysts or additives have sparked significant interest. The underlying mechanism is speculated to be ultrahigh electric fields at the air-water interface; smaller droplets present higher interfacial area and produce higher (detectable) H$_2$O$_2$ yields. Herein, we present an alternative explanation for these experimental observations. We compare H$_2$O$_2$ production in water microdroplets condensed from vapor produced via (i) heating water to 50-70 °C and (ii) ultrasonic humidification (as exploited in the original report). Water microdroplets condensed after heating do not show any enhancement in the H$_2$O$_2$ level in comparison to the bulk water, regardless of droplet size or the substrate wettability. In contrast, those condensed after ultrasonic humidification produce significantly higher H$_2$O$_2$ quantities. We conclude that the ultrasonication of water contributes to the H$_2$O$_2$ production, not droplet interfacial effects.
△ Less
Submitted 7 September, 2021;
originally announced September 2021.
-
Uncertainty evalutation through data modelling for dimensional nanoscale measurements
Authors:
J. Pétry,
B. De Boeck,
N. Sebaihi,
M. Coenegrachts,
T. Caebergs,
M. Dobre
Abstract:
A major bottleneck in nanoparticle measurements is the lack of comparability. Comparability of measurement results is obtained by metrological traceability, which is obtained by calibration. In the present work the calibration of dimensional nanoparticle measurements is performed through the construction of a calibration curve by comparison of measured reference standards to their certified value.…
▽ More
A major bottleneck in nanoparticle measurements is the lack of comparability. Comparability of measurement results is obtained by metrological traceability, which is obtained by calibration. In the present work the calibration of dimensional nanoparticle measurements is performed through the construction of a calibration curve by comparison of measured reference standards to their certified value. Subsequently, a general approach is proposed to perform a measurement uncertainty evaluation for a measured quantity when no comprehensive physical model is available, by statistically modelling appropriately selected measurement data. The experimental data is collected so that the influence of relevant parameters can be assessed by fitting a mixed model to the data. Furthermore, this model allows to generate a probability density function (PDF) for the concerned measured quantity. Applying this methodology to dimensional nanoparticle measurements leads to a PDF for a measured dimensional quantity of the nanoparticles. A PDF for the measurand, which is the certified counterpart of that measured dimensional quantity, can then be extracted by reporting a PDF for the measured dimensional quantity on the calibration curve. The PDF for the measurand grasps its total measurement uncertainty. Working in a fully Bayesian framework is natural due to the instrinsic caracter of the quantity of interest: the distribution of size rather than the size of one single particle. The developed methodology is applied to the particular case where dimensional nanoparticle measurements are performed using an atomic force microscope (AFM). The reference standards used to build a calibration curve are nano-gratings with step heights covering the application range of the calibration curve.
△ Less
Submitted 21 December, 2018;
originally announced December 2018.