Aortic Wall Stiffness Depends on Ultrasound Probe Pressure
Authors:
Marta Irene Bracco,
Jonas Peter Eiberg,
Ulver Spangsberg Lorenzen,
Stephane Avril,
Laurence Rouet
Abstract:
OBJECTIVE: Assessing the biomechanical behaviour of the aortic wall in vivo can potentially improve the diagnosis and prognosis of patients with abdominal aortic aneurysms (AAA). With ultrasound, AAA wall stiffness can be estimated as the diameter change in response to blood pressure. However, this measurement has shown limited reproducibility, possibly influenced by the unknown effects of the hig…
▽ More
OBJECTIVE: Assessing the biomechanical behaviour of the aortic wall in vivo can potentially improve the diagnosis and prognosis of patients with abdominal aortic aneurysms (AAA). With ultrasound, AAA wall stiffness can be estimated as the diameter change in response to blood pressure. However, this measurement has shown limited reproducibility, possibly influenced by the unknown effects of the highly variable ultrasound probe pressure. This study addressed this gap by analyzing time-resolved ultrasound sequences from AAA patients.METHOD: Two-dimensional ultrasound sequences were acquired from AAA patients, alternatively applying light and firm probe pressure. Diameter variations and stiffness were evaluated and compared. An in silico simulation was performed to support the in vivo observations.RESULTS: It was found that half of the AAAs were particularly responsive to the probe pressure: in these patients, the cyclic diameter variation between diastole and systole changed from 1% at light probe pressure to 5% at firm probe pressure and the estimated stiffness decreases by a factor of 6.3. Conversely, the other half of the patients were less responsive: diameter variations increased marginally and stiffness decreased by a factor of 1.5 when transitioning from light to firm probe pressure. Through numerical simulations, we were able to show that the rather counter-intuitive stiffness decrease observed in the responsive cohort is actually consistent with a biomechanical model.CONCLUSION: We conclude that probe pressure has an important effect on the estimation of AAA wall stiffness. Ultimately, our findings suggest potential implications for AAA mechanical characterization via ultrasound imaging.
△ Less
Submitted 13 December, 2023;
originally announced December 2023.
-
Anatomically constrained CT image translation for heterogeneous blood vessel segmentation
Authors:
Giammarco La Barbera,
Haithem Boussaid,
Francesco Maso,
Sabine Sarnacki,
Laurence Rouet,
Pietro Gori,
Isabelle Bloch
Abstract:
Anatomical structures such as blood vessels in contrast-enhanced CT (ceCT) images can be challenging to segment due to the variability in contrast medium diffusion. The combined use of ceCT and contrast-free (CT) CT images can improve the segmentation performances, but at the cost of a double radiation exposure. To limit the radiation dose, generative models could be used to synthesize one modalit…
▽ More
Anatomical structures such as blood vessels in contrast-enhanced CT (ceCT) images can be challenging to segment due to the variability in contrast medium diffusion. The combined use of ceCT and contrast-free (CT) CT images can improve the segmentation performances, but at the cost of a double radiation exposure. To limit the radiation dose, generative models could be used to synthesize one modality, instead of acquiring it. The CycleGAN approach has recently attracted particular attention because it alleviates the need for paired data that are difficult to obtain. Despite the great performances demonstrated in the literature, limitations still remain when dealing with 3D volumes generated slice by slice from unpaired datasets with different fields of view. We present an extension of CycleGAN to generate high fidelity images, with good structural consistency, in this context. We leverage anatomical constraints and automatic region of interest selection by adapting the Self-Supervised Body Regressor. These constraints enforce anatomical consistency and allow feeding anatomically-paired input images to the algorithm. Results show qualitative and quantitative improvements, compared to stateof-the-art methods, on the translation task between ceCT and CT images (and vice versa).
△ Less
Submitted 4 October, 2022;
originally announced October 2022.
-
Automatic size and pose homogenization with spatial transformer network to improve and accelerate pediatric segmentation
Authors:
Giammarco La Barbera,
Pietro Gori,
Haithem Boussaid,
Bruno Belucci,
Alessandro Delmonte,
Jeanne Goulin,
Sabine Sarnacki,
Laurence Rouet,
Isabelle Bloch
Abstract:
Due to a high heterogeneity in pose and size and to a limited number of available data, segmentation of pediatric images is challenging for deep learning methods. In this work, we propose a new CNN architecture that is pose and scale invariant thanks to the use of Spatial Transformer Network (STN). Our architecture is composed of three sequential modules that are estimated together during training…
▽ More
Due to a high heterogeneity in pose and size and to a limited number of available data, segmentation of pediatric images is challenging for deep learning methods. In this work, we propose a new CNN architecture that is pose and scale invariant thanks to the use of Spatial Transformer Network (STN). Our architecture is composed of three sequential modules that are estimated together during training: (i) a regression module to estimate a similarity matrix to normalize the input image to a reference one; (ii) a differentiable module to find the region of interest to segment; (iii) a segmentation module, based on the popular UNet architecture, to delineate the object. Unlike the original UNet, which strives to learn a complex mapping, including pose and scale variations, from a finite training dataset, our segmentation module learns a simpler mapping focusing on images with normalized pose and size. Furthermore, the use of an automatic bounding box detection through STN allows saving time and especially memory, while keeping similar performance. We test the proposed method in kidney and renal tumor segmentation on abdominal pediatric CT scanners. Results indicate that the estimated STN homogenization of size and pose accelerates the segmentation (25h), compared to standard data-augmentation (33h), while obtaining a similar quality for the kidney (88.01\% of Dice score) and improving the renal tumor delineation (from 85.52\% to 87.12\%).
△ Less
Submitted 6 July, 2021;
originally announced July 2021.