-
Simultaneous Deep Learning of Myocardium Segmentation and T2 Quantification for Acute Myocardial Infarction MRI
Authors:
Yirong Zhou,
Chengyan Wang,
Mengtian Lu,
Kunyuan Guo,
Zi Wang,
Dan Ruan,
Rui Guo,
Peijun Zhao,
Jianhua Wang,
Naiming Wu,
Jianzhong Lin,
Yinyin Chen,
Hang Jin,
Lianxin Xie,
Lilan Wu,
Liuhong Zhu,
Jianjun Zhou,
Congbo Cai,
He Wang,
Xiaobo Qu
Abstract:
In cardiac Magnetic Resonance Imaging (MRI) analysis, simultaneous myocardial segmentation and T2 quantification are crucial for assessing myocardial pathologies. Existing methods often address these tasks separately, limiting their synergistic potential. To address this, we propose SQNet, a dual-task network integrating Transformer and Convolutional Neural Network (CNN) components. SQNet features…
▽ More
In cardiac Magnetic Resonance Imaging (MRI) analysis, simultaneous myocardial segmentation and T2 quantification are crucial for assessing myocardial pathologies. Existing methods often address these tasks separately, limiting their synergistic potential. To address this, we propose SQNet, a dual-task network integrating Transformer and Convolutional Neural Network (CNN) components. SQNet features a T2-refine fusion decoder for quantitative analysis, leveraging global features from the Transformer, and a segmentation decoder with multiple local region supervision for enhanced accuracy. A tight coupling module aligns and fuses CNN and Transformer branch features, enabling SQNet to focus on myocardium regions. Evaluation on healthy controls (HC) and acute myocardial infarction patients (AMI) demonstrates superior segmentation dice scores (89.3/89.2) compared to state-of-the-art methods (87.7/87.9). T2 quantification yields strong linear correlations (Pearson coefficients: 0.84/0.93) with label values for HC/AMI, indicating accurate mapping. Radiologist evaluations confirm SQNet's superior image quality scores (4.60/4.58 for segmentation, 4.32/4.42 for T2 quantification) over state-of-the-art methods (4.50/4.44 for segmentation, 3.59/4.37 for T2 quantification). SQNet thus offers accurate simultaneous segmentation and quantification, enhancing cardiac disease diagnosis, such as AMI.
△ Less
Submitted 29 May, 2024; v1 submitted 17 May, 2024;
originally announced May 2024.
-
Topological phases of extended Su-Schrieffer-Heeger-Hubbard model
Authors:
Pei-Jie Chang,
Jinghui Pi,
Muxi Zheng,
Yu-Ting Lei,
Dong Ruan,
Gui-Lu Long
Abstract:
Despite extensive studies on the one-dimensional Su-Schrieffer-Heeger-Hubbard (SSHH) model, the variant incorporating next-nearest neighbour hopping remains largely unexplored. Here, we investigate the ground-state properties of this extended SSHH model using the constrained-path auxiliary-field quantum Monte Carlo (CP-AFQMC) method. We show that this model exhibits rich topological phases, charac…
▽ More
Despite extensive studies on the one-dimensional Su-Schrieffer-Heeger-Hubbard (SSHH) model, the variant incorporating next-nearest neighbour hopping remains largely unexplored. Here, we investigate the ground-state properties of this extended SSHH model using the constrained-path auxiliary-field quantum Monte Carlo (CP-AFQMC) method. We show that this model exhibits rich topological phases, characterized by robust edge states against interaction. We quantify the properties of these edge states by analyzing spin correlation and second-order Rényi entanglement entropy. The system exhibits long-range spin correlation and near-zero Rényi entropy at half-filling. Besides, there is a long-range anti-ferromagnetic order at quarter-filling. Interestingly, an external magnetic field disrupts this long-range anti-ferromagnetic order, restoring long-range spin correlation and near-zero Rényi entropy. Furthermore, our work provides a paradigm studying topological properties in large interacting systems via the CP-AFQMC algorithm.
△ Less
Submitted 19 June, 2024; v1 submitted 16 May, 2024;
originally announced May 2024.
-
The Evolution of Quantum Secure Direct Communication: On the Road to the Qinternet
Authors:
Dong Pan,
Gui-Lu Long,
Liuguo Yin,
Yu-Bo Sheng,
Dong Ruan,
Soon Xin Ng,
Jianhua Lu,
Lajos Hanzo
Abstract:
Communication security has to evolve to a higher plane in the face of the threat from the massive computing power of the emerging quantum computers. Quantum secure direct communication (QSDC) constitutes a promising branch of quantum communication, which is provably secure and overcomes the threat of quantum computing, whilst conveying secret messages directly via the quantum channel. In this surv…
▽ More
Communication security has to evolve to a higher plane in the face of the threat from the massive computing power of the emerging quantum computers. Quantum secure direct communication (QSDC) constitutes a promising branch of quantum communication, which is provably secure and overcomes the threat of quantum computing, whilst conveying secret messages directly via the quantum channel. In this survey, we highlight the motivation and the status of QSDC research with special emphasis on its theoretical basis and experimental verification. We will detail the associated point-to-point communication protocols and show how information is protected and transmitted. Finally, we discuss the open challenges as well as the future trends of QSDC networks, emphasizing again that QSDC is not a pure quantum key distribution (QKD) protocol, but a fully-fledged secure communication scheme.
△ Less
Submitted 23 November, 2023;
originally announced November 2023.
-
A Two-Step Framework for Multi-Material Decomposition of Dual Energy Computed Tomography from Projection Domain
Authors:
Di Xu,
Qihui Lyu,
Dan Ruan,
Ke Sheng
Abstract:
Dual-energy computed tomography (DECT) utilizes separate X-ray energy spectra to improve multi-material decomposition (MMD) for various diagnostic applications. However accurate decomposing more than two types of material remains challenging using conventional methods. Deep learning (DL) methods have shown promise to improve the MMD performance, but typical approaches of conducing DL-MMD in the im…
▽ More
Dual-energy computed tomography (DECT) utilizes separate X-ray energy spectra to improve multi-material decomposition (MMD) for various diagnostic applications. However accurate decomposing more than two types of material remains challenging using conventional methods. Deep learning (DL) methods have shown promise to improve the MMD performance, but typical approaches of conducing DL-MMD in the image domain fail to fully utilize projection information or under iterative setup are computationally inefficient in both training and prediction. In this work, we present a clinical-applicable MMD (>2) framework rFast-MMDNet, operating with raw projection data in non-recursive setup, for breast tissue differentiation. rFast-MMDNet is a two-stage algorithm, including stage-one SinoNet to perform dual energy projection decomposition on tissue sinograms and stage-two FBP-DenoiseNet to perform domain adaptation and image post-processing. rFast-MMDNet was tested on a 2022 DL-Spectral-Challenge breast phantom dataset. The two stages of rFast-MMDNet were evaluated separately and then compared with four noniterative reference methods including a direct inversion method (AA-MMD), an image domain DL method (ID-UNet), AA-MMD/ID-UNet + DenoiseNet and a sinogram domain DL method (Triple-CBCT). Our results show that models trained from information stored in DE transmission domain can yield high-fidelity decomposition of the adipose, calcification, and fibroglandular materials with averaged RMSE, MAE, negative PSNR, and SSIM of 0.004+/-~0, 0.001+/-~0, -45.027+/-~0.542, and 0.002+/-~0 benchmarking to the ground truth, respectively. Training of entire rFast-MMDNet on a 4xRTX A6000 GPU cluster took a day with inference time <1s. All DL methods generally led to more accurate MMD than AA-MMD. rFast-MMDNet outperformed Triple-CBCT, but both are superior to the image-domain based methods.
△ Less
Submitted 31 October, 2023;
originally announced November 2023.
-
Statistical Bias in the Hubble Constant and Mass Power Law Slope for Mock Strong Lenses
Authors:
Dilys Ruan,
Charles R. Keeton
Abstract:
Strong gravitational lensing offers constraints on the Hubble constant that are independent of other methods. However, those constraints are subject to uncertainties in lens models. Previous studies suggest that using an elliptical power law + external shear (EPL+XS) for the lensing galaxy can yield results that are precise but inaccurate. We examine such models by generating and fitting mock lens…
▽ More
Strong gravitational lensing offers constraints on the Hubble constant that are independent of other methods. However, those constraints are subject to uncertainties in lens models. Previous studies suggest that using an elliptical power law + external shear (EPL+XS) for the lensing galaxy can yield results that are precise but inaccurate. We examine such models by generating and fitting mock lenses which produces multiple images of a background quasar-like point source. Despite using the same model for input and output, we find statistical bias in the Hubble constant on the order of 3% to 5%, depending on whether the elliptical lenses have noise or not. The phase space distribution has a `flared' shape that causes the mass power law slope to be underestimated and the Hubble constant to be overestimated. The bias varies with image configuration, which we quantify through annulus length between images with the first and second time delays ($Δr_{1,2}$). The statistical bias is worse for configurations that have narrow annuli (e.g., symmetric cross configurations). Assuming a source at redshift 2.0 and an EPL+XS lens at redshift 0.3, we find that the bias can be reduced, but not eliminated, if we limit the sample to systems with annulus lengths $Δr_{1,2} \gtrsim 0.3$ arcsec. As lens samples grow, it may be helpful to prioritize this range of image configurations for follow-up observation and analysis.
△ Less
Submitted 1 July, 2024; v1 submitted 28 September, 2023;
originally announced September 2023.
-
Learning Dynamic MRI Reconstruction with Convolutional Network Assisted Reconstruction Swin Transformer
Authors:
Di Xu,
Hengjie Liu,
Dan Ruan,
Ke Sheng
Abstract:
Dynamic magnetic resonance imaging (DMRI) is an effective imaging tool for diagnosis tasks that require motion tracking of a certain anatomy. To speed up DMRI acquisition, k-space measurements are commonly undersampled along spatial or spatial-temporal domains. The difficulty of recovering useful information increases with increasing undersampling ratios. Compress sensing was invented for this pur…
▽ More
Dynamic magnetic resonance imaging (DMRI) is an effective imaging tool for diagnosis tasks that require motion tracking of a certain anatomy. To speed up DMRI acquisition, k-space measurements are commonly undersampled along spatial or spatial-temporal domains. The difficulty of recovering useful information increases with increasing undersampling ratios. Compress sensing was invented for this purpose and has become the most popular method until deep learning (DL) based DMRI reconstruction methods emerged in the past decade. Nevertheless, existing DL networks are still limited in long-range sequential dependency understanding and computational efficiency and are not fully automated. Considering the success of Transformers positional embedding and "swin window" self-attention mechanism in the vision community, especially natural video understanding, we hereby propose a novel architecture named Reconstruction Swin Transformer (RST) for 4D MRI. RST inherits the backbone design of the Video Swin Transformer with a novel reconstruction head introduced to restore pixel-wise intensity. A convolution network called SADXNet is used for rapid initialization of 2D MR frames before RST learning to effectively reduce the model complexity, GPU hardware demand, and training time. Experimental results in the cardiac 4D MR dataset further substantiate the superiority of RST, achieving the lowest RMSE of 0.0286 +/- 0.0199 and 1 - SSIM of 0.0872 +/- 0.0783 on 9 times accelerated validation sequences.
△ Less
Submitted 18 September, 2023;
originally announced September 2023.
-
2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy
Authors:
Farhang Bayat,
Dan Ruan,
Moyed Miften,
Cem Altunbas
Abstract:
Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To further improve image quality in CBCT, 2D antiscatter grid based scatter rejection was combined with a raw data processing pipeline and iterative image reconstruction…
▽ More
Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To further improve image quality in CBCT, 2D antiscatter grid based scatter rejection was combined with a raw data processing pipeline and iterative image reconstruction. The culmination of these steps was referred as quantitative CBCT, qCBCT. qCBCT data processing steps include 2D antiscatter grid implementation, measurement based residual scatter, image lag, and beam hardening correction for offset detector geometry CBCT with a bow tie filter. Images were reconstructed with iterative image reconstruction to reduce image noise. To evaluate image quality, qCBCT acquisitions were performed using a variety of phantoms to investigate the effect of object size and its composition on image quality. qCBCT image quality was benchmarked against clinical CBCT and MDCT images. Addition of image lag and beam hardening correction to scatter suppression reduced HU degradation in qCBCT by 10 HU and 40 HU, respectively. When compared to gold standard MDCT, mean HU errors in qCBCT and clinical CBCT were 10 HU and 27 HU, respectively. HU inaccuracy due to change in phantom size was 22 HU and 85 HU in qCBCT and clinical CBCT images, respectively. With iterative reconstruction, contrast to noise ratio improved by a factor of 1.25 when compared to clinical CBCT protocols. Robust artifact and noise suppression in qCBCT images can reduce the image quality gap between CBCT and MDCT, improving the promise of qCBCT in fulfilling the tasks that demand high quantitative accuracy, such as CBCT based dose calculations and treatment response assessment in image guided radiation therapy.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
An Efficient and Robust Method for Chest X-Ray Rib Suppression that Improves Pulmonary Abnormality Diagnosis
Authors:
Di Xu,
Qifan Xu,
Kevin Nhieu,
Dan Ruan,
Ke Sheng
Abstract:
Suppression of thoracic bone shadows on chest X-rays (CXRs) has been indicated to improve the diagnosis of pulmonary disease. Previous approaches can be categorized as unsupervised physical and supervised deep learning models. Nevertheless, with physical models able to preserve morphological details but at the cost of extremely long processing time, existing DL methods face challenges of gathering…
▽ More
Suppression of thoracic bone shadows on chest X-rays (CXRs) has been indicated to improve the diagnosis of pulmonary disease. Previous approaches can be categorized as unsupervised physical and supervised deep learning models. Nevertheless, with physical models able to preserve morphological details but at the cost of extremely long processing time, existing DL methods face challenges of gathering sufficient/qualitative ground truth (GT) for robust training, thus leading to failure in maintaining clinically acceptable false positive rates. We hereby propose a generalizable yet efficient workflow of two stages: (1) training pairs generation with GT bone shadows eliminated in by a physical model in spatially transformed gradient fields. (2) fully supervised image denoising network training on stage-one datasets for fast rib removal on incoming CXRs. For step two, we designed a densely connected network called SADXNet, combined with peak signal to noise ratio and multi-scale structure similarity index measure objective minimization to suppress bony structures. The SADXNet organizes spatial filters in U shape (e.g., X=7; filters = 16, 64, 256, 512, 256, 64, 16) and preserves the feature map dimension throughout the network flow. Visually, SADXNet can suppress the rib edge and that near the lung wall/vertebra without jeopardizing the vessel/abnormality conspicuity. Quantitively, it achieves RMSE of ~0 during testing with one prediction taking <1s. Downstream tasks including lung nodule detection as well as common lung disease classification and localization are used to evaluate our proposed rib suppression mechanism. We observed 3.23% and 6.62% area under the curve (AUC) increase as well as 203 and 385 absolute false positive decrease for lung nodule detection and common lung disease localization, separately.
△ Less
Submitted 19 February, 2023;
originally announced February 2023.
-
Physics-informed Deep Diffusion MRI Reconstruction with Synthetic Data: Break Training Data Bottleneck in Artificial Intelligence
Authors:
Chen Qian,
Yuncheng Gao,
Mingyang Han,
Zi Wang,
Dan Ruan,
Yu Shen,
Yaping Wu,
Yirong Zhou,
Chengyan Wang,
Boyu Jiang,
Ran Tao,
Zhigang Wu,
Jiazheng Wang,
Liuhong Zhu,
Yi Guo,
Taishan Kang,
Jianzhong Lin,
Tao Gong,
Chen Yang,
Guoqiang Fei,
Meijin Lin,
Di Guo,
Jianjun Zhou,
Meiyun Wang,
Xiaobo Qu
Abstract:
Diffusion magnetic resonance imaging (MRI) is the only imaging modality for non-invasive movement detection of in vivo water molecules, with significant clinical and research applications. Diffusion MRI (DWI) acquired by multi-shot techniques can achieve higher resolution, better signal-to-noise ratio, and lower geometric distortion than single-shot, but suffers from inter-shot motion-induced arti…
▽ More
Diffusion magnetic resonance imaging (MRI) is the only imaging modality for non-invasive movement detection of in vivo water molecules, with significant clinical and research applications. Diffusion MRI (DWI) acquired by multi-shot techniques can achieve higher resolution, better signal-to-noise ratio, and lower geometric distortion than single-shot, but suffers from inter-shot motion-induced artifacts. These artifacts cannot be removed prospectively, leading to the absence of artifact-free training labels. Thus, the potential of deep learning in multi-shot DWI reconstruction remains largely untapped. To break the training data bottleneck, here, we propose a Physics-Informed Deep DWI reconstruction method (PIDD) to synthesize high-quality paired training data by leveraging the physical diffusion model (magnitude synthesis) and inter-shot motion-induced phase model (motion phase synthesis). The network is trained only once with 100,000 synthetic samples, achieving encouraging results on multiple realistic in vivo data reconstructions. Advantages over conventional methods include: (a) Better motion artifact suppression and reconstruction stability; (b) Outstanding generalization to multi-scenario reconstructions, including multi-resolution, multi-b-value, multi-undersampling, multi-vendor, and multi-center; (c) Excellent clinical adaptability to patients with verifications by seven experienced doctors (p<0.001). In conclusion, PIDD presents a novel deep learning framework by exploiting the power of MRI physics, providing a cost-effective and explainable way to break the data bottleneck in deep learning medical imaging.
△ Less
Submitted 5 February, 2024; v1 submitted 20 October, 2022;
originally announced October 2022.
-
Optomechanical compensatory cooling mechanism with exceptional points
Authors:
Guo-Qing Qin,
Xuan Mao,
Hao Zhang,
Peng-Yu Wen,
Gui-Qin Li,
Dong Ruan,
Gui-Lu Long
Abstract:
The ground state cooling of Brillouin scattering optomechanical system is limited by defects in practical sample. In this paper, we propose a new compensatory cooling mechanism for Brillouin scattering optomechanical system with exceptional points (EPs). By using the EPs both in optical and mechanical modes, the limited cooling process is compensated effectively. The dual-EPs system, which is disc…
▽ More
The ground state cooling of Brillouin scattering optomechanical system is limited by defects in practical sample. In this paper, we propose a new compensatory cooling mechanism for Brillouin scattering optomechanical system with exceptional points (EPs). By using the EPs both in optical and mechanical modes, the limited cooling process is compensated effectively. The dual-EPs system, which is discovered in this work for the first time, can be induced by two defects with specific relative angles and has function of not only actively manipulating the coupling strength of optical modes but also the Brillouin phonon modes. Our results provide new tools to manipulate the optomechanical interaction in multi-mode systems and open the possibility of quantum state transfer and quantum interface protocols based on phonon cooling in quantum applications.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
To what extent can Plug-and-Play methods outperform neural networks alone in low-dose CT reconstruction
Authors:
Qifan Xu,
Qihui Lyu,
Dan Ruan,
Ke Sheng
Abstract:
The Plug-and-Play (PnP) framework was recently introduced for low-dose CT reconstruction to leverage the interpretability and the flexibility of model-based methods to incorporate various plugins, such as trained deep learning (DL) neural networks. However, the benefits of PnP vs. state-of-the-art DL methods have not been clearly demonstrated. In this work, we proposed an improved PnP framework to…
▽ More
The Plug-and-Play (PnP) framework was recently introduced for low-dose CT reconstruction to leverage the interpretability and the flexibility of model-based methods to incorporate various plugins, such as trained deep learning (DL) neural networks. However, the benefits of PnP vs. state-of-the-art DL methods have not been clearly demonstrated. In this work, we proposed an improved PnP framework to address the previous limitations and develop clinical-relevant segmentation metrics for quantitative result assessment. Compared with the DL alone methods, our proposed PnP framework was slightly inferior in MSE and PSNR. However, the power spectrum of the resulting images better matched that of full-dose images than that of DL denoised images. The resulting images supported higher accuracy in airway segmentation than DL denoised images for all the ten patients in the test set, more substantially on the airways with a cross-section smaller than 0.61cm$^2$, and outperformed the DL denoised images for 45 out of 50 lung lobes in lobar segmentation. Our PnP method proved to be significantly better at preserving the image texture, which translated to task-specific benefits in automated structure segmentation and detection.
△ Less
Submitted 14 February, 2022;
originally announced February 2022.
-
Scalable higher-order exceptional surface with passive resonators
Authors:
Hong Yang,
Xuan Mao,
Guo-Qing Qin,
Min Wang,
Hao Zhang,
Dong Ruan,
Gui-Lu Long
Abstract:
The sensitivity of perturbation sensing can be effectively enhanced with higher-order exceptional points due to the nonlinear response to frequency splitting. However, the experimental implementation is challenging since all the parameters need to be precisely prepared. The emergence of exceptional surface (ES) improves the robustness of the system to the external environment, while maintaining th…
▽ More
The sensitivity of perturbation sensing can be effectively enhanced with higher-order exceptional points due to the nonlinear response to frequency splitting. However, the experimental implementation is challenging since all the parameters need to be precisely prepared. The emergence of exceptional surface (ES) improves the robustness of the system to the external environment, while maintaining the same sensitivity. Here, we propose the first scalable protocol for realizing photonic high-order exceptional surface with passive resonators. By adding one or more additional passive resonators in the low-order ES photonic system, the 3- or arbitrary N-order ES is constructed and proved to be easily realized in experiment. We show that the sensitivity is enhanced and experimental demonstration is more resilent against the fabrication errors. The additional phase-modulation effect is also investigated.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
Feature Decomposition and Reconstruction Learning for Effective Facial Expression Recognition
Authors:
Delian Ruan,
Yan Yan,
Shenqi Lai,
Zhenhua Chai,
Chunhua Shen,
Hanzi Wang
Abstract:
In this paper, we propose a novel Feature Decomposition and Reconstruction Learning (FDRL) method for effective facial expression recognition. We view the expression information as the combination of the shared information (expression similarities) across different expressions and the unique information (expression-specific variations) for each expression. More specifically, FDRL mainly consists o…
▽ More
In this paper, we propose a novel Feature Decomposition and Reconstruction Learning (FDRL) method for effective facial expression recognition. We view the expression information as the combination of the shared information (expression similarities) across different expressions and the unique information (expression-specific variations) for each expression. More specifically, FDRL mainly consists of two crucial networks: a Feature Decomposition Network (FDN) and a Feature Reconstruction Network (FRN). In particular, FDN first decomposes the basic features extracted from a backbone network into a set of facial action-aware latent features to model expression similarities. Then, FRN captures the intra-feature and inter-feature relationships for latent features to characterize expression-specific variations, and reconstructs the expression feature. To this end, two modules including an intra-feature relation modeling module and an inter-feature relation modeling module are developed in FRN. Experimental results on both the in-the-lab databases (including CK+, MMI, and Oulu-CASIA) and the in-the-wild databases (including RAF-DB and SFEW) show that the proposed FDRL method consistently achieves higher recognition accuracy than several state-of-the-art methods. This clearly highlights the benefit of feature decomposition and reconstruction for classifying expressions.
△ Less
Submitted 20 April, 2021; v1 submitted 11 April, 2021;
originally announced April 2021.
-
Experimental realization of sensitivity enhancement and suppression with exceptional surfaces
Authors:
Guoqing Qin,
Ranran Xie,
Hao Zhang,
Yunqi Hu,
Min Wang,
Haitan Xu,
Fuchuan Lei,
Dong Ruan,
Gui-Lu Long
Abstract:
By preparing a sensor system around isolated exceptional points, one can obtain a great enhancement of the sensitivity benefiting from the non-Hermiticity. However, this comes at the cost of reduction of the flexibility of the system, which is critical for practical applications. By generalizing the exceptional points to exceptional surfaces, it has been theoretically proposed recently that enhanc…
▽ More
By preparing a sensor system around isolated exceptional points, one can obtain a great enhancement of the sensitivity benefiting from the non-Hermiticity. However, this comes at the cost of reduction of the flexibility of the system, which is critical for practical applications. By generalizing the exceptional points to exceptional surfaces, it has been theoretically proposed recently that enhanced sensitivity and flexibility can be combined. Here, we experimentally demonstrate an exceptional surface in a non-Hermitian photonic sensing system, which is composed of a whispering-gallery-mode microresonator and two nanofiber waveguides, resulting in a unidirectional coupling between two degenerate counter-propagating modes with an external optical isolator. The system is simple, robust, and can be easily operated around an exceptional surface. On the one hand, we observe sensitivity enhancement by monitoring the resonant frequency splitting caused by small perturbations. This demonstration of exceptional-surface-enhanced sensitivity paves the way for practical non-Hermitian sensing applications. On the other hand, we also show the suppression of frequency splitting around the exceptional surface for the first time.
△ Less
Submitted 23 May, 2021; v1 submitted 15 September, 2020;
originally announced September 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Experimental free-space quantum secure direct communication and its security analysis
Authors:
Dong Pan,
Zaisheng Lin,
Jiawei Wu,
Zhen Sun,
Dong Ruan,
Liuguo Yin,
Guilu Long
Abstract:
We report an experimental implementation of free-space quantum secure direct communication based on single photons. The quantum communication scheme uses phase encoding, and the asymmetric Mach-Zehnder interferometer is optimized so as to automatically compensate phase drift of the photons during their transitions over the free-space medium. An information transmission rate of 500 bps over a 10-me…
▽ More
We report an experimental implementation of free-space quantum secure direct communication based on single photons. The quantum communication scheme uses phase encoding, and the asymmetric Mach-Zehnder interferometer is optimized so as to automatically compensate phase drift of the photons during their transitions over the free-space medium. An information transmission rate of 500 bps over a 10-meter free space with a mean quantum bit error rate of 0.49%$\pm$0.27% is achieved. The security is analyzed under the scenario that Eve performs collective attack and photon number splitting collective attack. Our results show that quantum secure direct communication is feasible in free space.
△ Less
Submitted 3 September, 2020; v1 submitted 11 May, 2020;
originally announced May 2020.
-
A novel 3D multi-path DenseNet for improving automatic segmentation of glioblastoma on pre-operative multi-modal MR images
Authors:
Jie Fu,
Kamal Singhrao,
X. Sharon Qi,
Yingli Yang,
Dan Ruan,
John H. Lewis
Abstract:
Convolutional neural networks have achieved excellent results in automatic medical image segmentation. In this study, we proposed a novel 3D multi-path DenseNet for generating the accurate glioblastoma (GBM) tumor contour from four multi-modal pre-operative MR images. We hypothesized that the multi-path architecture could achieve more accurate segmentation than a single-path architecture. 258 GBM…
▽ More
Convolutional neural networks have achieved excellent results in automatic medical image segmentation. In this study, we proposed a novel 3D multi-path DenseNet for generating the accurate glioblastoma (GBM) tumor contour from four multi-modal pre-operative MR images. We hypothesized that the multi-path architecture could achieve more accurate segmentation than a single-path architecture. 258 GBM patients were included in this study. Each patient had four MR images (T1-weighted, contrast-enhanced T1-weighted, T2-weighted, and FLAIR) and the manually segmented tumor contour. We built a 3D multi-path DenseNet that could be trained to generate the corresponding GBM tumor contour from the four MR images. A 3D single-path DenseNet was also built for comparison. Both DenseNets were based on the encoder-decoder architecture. All four images were concatenated and fed into a single encoder path in the single-path DenseNet, while each input image had its own encoder path in the multi-path DenseNet. The patient cohort was randomly split into a training set of 180 patients, a validation set of 39 patients, and a testing set of 39 patients. Model performance was evaluated using the Dice similarity coefficient (DSC), average surface distance (ASD), and 95% Hausdorff distance (HD95%). Wilcoxon signed-rank tests were conducted to examine the model differences. The single-path DenseNet achieved a DSC of 0.911$\pm$0.060, ASD of 1.3$\pm$0.7 mm, and HD95% of 5.2$\pm$7.1 mm, while the multi-path DenseNet achieved a DSC of 0.922$\pm$0.041, ASD of 1.1$\pm$0.5 mm, and HD95% of 3.9$\pm$3.3 mm. The p-values of all Wilcoxon signed-rank tests were less than 0.05. Both 3D DenseNets generated GBM tumor contours in good agreement with the manually segmented contours from multi-modal MR images. The multi-path DenseNet achieved more accurate tumor segmentation than the single-path DenseNet.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
Discovery of a Pulsar Wind Nebula around B0950+08 with the ELWA
Authors:
D. Ruan,
G. B. Taylor,
J. Dowell,
K. Stovall,
F. K. Schinzel,
P. B. Demorest
Abstract:
With the Expanded Long Wavelength Array (ELWA) and pulsar binning techniques, we searched for off-pulse emission from PSR B0950+08 at 76 MHz. Previous studies suggest that off-pulse emission can be due to pulsar wind nebulae (PWNe) in younger pulsars. Other studies, such as that done by Basu et al. (2012), propose that in older pulsars this emission extends to some radius that is on the order of t…
▽ More
With the Expanded Long Wavelength Array (ELWA) and pulsar binning techniques, we searched for off-pulse emission from PSR B0950+08 at 76 MHz. Previous studies suggest that off-pulse emission can be due to pulsar wind nebulae (PWNe) in younger pulsars. Other studies, such as that done by Basu et al. (2012), propose that in older pulsars this emission extends to some radius that is on the order of the light cylinder radius, and is magnetospheric in origin. Through imaging analysis we conclude that this older pulsar with a spin-down age of 17 Myr has a surrounding PWN, which is unexpected since as a pulsar ages its PWN spectrum is thought to shift from being synchrotron to inverse-Compton-scattering dominated. At 76 MHz, the average flux density of the off-pulse emission is 0.59 $\pm$ 0.16 Jy. The off-pulse emission from B0950+08 is $\sim$ 110 $\pm$ 17 arcseconds (0.14 $\pm$ 0.02 pc) in size, extending well-beyond the light cylinder diameter and ruling out a magnetospheric origin. Using data from our observation and the surveys VLSSr, TGSS, NVSS, FIRST, and VLASS, we have found that the spectral index for B0950+08 is about -1.36 $\pm$ 0.20, while the PWN's spectral index is steeper than -1.85 $\pm$ 0.45.
△ Less
Submitted 7 May, 2020; v1 submitted 7 May, 2020;
originally announced May 2020.
-
Instant single-pixel imaging: on-chip real-time implementation based on instant ghost imaging algorithm
Authors:
Zhe Yang,
Jun Liu,
Wei-Xing Zhang,
Dong Ruan,
Jun-Lin Li
Abstract:
Single-pixel imaging (SPI) uses a single-pixel detector to create an image of an object. SPI relies on a computer to construct an image, thus increasing both the size and cost of SPI and limiting its application. We developed instant single-pixel imaging (ISPI), an on-chip SPI system that implements real-time imaging at a rate of 25 fps. ISPI uses the instant ghost imaging algorithm we proposed wh…
▽ More
Single-pixel imaging (SPI) uses a single-pixel detector to create an image of an object. SPI relies on a computer to construct an image, thus increasing both the size and cost of SPI and limiting its application. We developed instant single-pixel imaging (ISPI), an on-chip SPI system that implements real-time imaging at a rate of 25 fps. ISPI uses the instant ghost imaging algorithm we proposed which leverages signal differences for image creation. It does not require a computer, which greatly reduces its cost and size. The reconstruct time of ISPI for image creation is almost zero because little processing is required after signal detection. ISPI paves the way for the practical application of SPI.
△ Less
Submitted 31 January, 2020;
originally announced February 2020.
-
An automatic deep learning-based workflow for glioblastoma survival prediction using pre-operative multimodal MR images
Authors:
Jie Fu,
Kamal Singhrao,
Xinran Zhong,
Yu Gao,
Sharon Qi,
Yingli Yang,
Dan Ruan,
John H Lewis
Abstract:
We proposed a fully automatic workflow for glioblastoma (GBM) survival prediction using deep learning (DL) methods. 285 glioma (210 GBM, 75 low-grade glioma) patients were included. 163 of the GBM patients had overall survival (OS) data. Every patient had four pre-operative MR scans and manually drawn tumor contours. For automatic tumor segmentation, a 3D convolutional neural network (CNN) was tra…
▽ More
We proposed a fully automatic workflow for glioblastoma (GBM) survival prediction using deep learning (DL) methods. 285 glioma (210 GBM, 75 low-grade glioma) patients were included. 163 of the GBM patients had overall survival (OS) data. Every patient had four pre-operative MR scans and manually drawn tumor contours. For automatic tumor segmentation, a 3D convolutional neural network (CNN) was trained and validated using 122 glioma patients. The trained model was applied to the remaining 163 GBM patients to generate tumor contours. The handcrafted and DL-based radiomic features were extracted from auto-contours using explicitly designed algorithms and a pre-trained CNN respectively. 163 GBM patients were randomly split into training (n=122) and testing (n=41) sets for survival analysis. Cox regression models with regularization techniques were trained to construct the handcrafted and DL-based signatures. The prognostic power of the two signatures was evaluated and compared. The 3D CNN achieved an average Dice coefficient of 0.85 across 163 GBM patients for tumor segmentation. The handcrafted signature achieved a C-index of 0.64 (95% CI: 0.55-0.73), while the DL-based signature achieved a C-index of 0.67 (95% CI: 0.57-0.77). Unlike the handcrafted signature, the DL-based signature successfully stratified testing patients into two prognostically distinct groups (p-value<0.01, HR=2.80, 95% CI: 1.26-6.24). The proposed 3D CNN generated accurate GBM tumor contours from four MR images. The DL-based signature resulted in better GBM survival prediction, in terms of higher C-index and significant patient stratification, than the handcrafted signature. The proposed automatic radiomic workflow demonstrated the potential of improving patient stratification and survival prediction in GBM patients.
△ Less
Submitted 29 January, 2020;
originally announced January 2020.
-
Instant ghost imaging: improving robustness for ghost imaging subject to optical background noise
Authors:
Zhe Yang,
Wei-Xing Zhang,
Ma-Chi Zhang,
Dong Ruan,
Jun-Lin Li
Abstract:
Ghost imaging (GI) is an imaging technique that uses the second-order correlation between two light beams to obtain the image of an object. However, standard GI is affected by optical background noise, which reduces its practical use. We investigated the robustness of an instant ghost imaging (IGI) algorithm against optical background noise and compare it with the conventional GI algorithm. Our re…
▽ More
Ghost imaging (GI) is an imaging technique that uses the second-order correlation between two light beams to obtain the image of an object. However, standard GI is affected by optical background noise, which reduces its practical use. We investigated the robustness of an instant ghost imaging (IGI) algorithm against optical background noise and compare it with the conventional GI algorithm. Our results show that IGI is extremely resistant to spatiotemporally varying optical background noise that can change over a large range. When the noise is large in relation to the signal, IGI will still perform well in conditions that prevent the conventional GI algorithm from generating an image because IGI uses signal differences for imaging. Signal differences are intrinsically resistant to common noise modes, so the IGI algorithm is strongly robust against noise. This research is of great significance for the practical application of GI.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.
-
Fully Automated Multi-Organ Segmentation in Abdominal Magnetic Resonance Imaging with Deep Neural Networks
Authors:
Yuhua Chen,
Dan Ruan,
Jiayu Xiao,
Lixia Wang,
Bin Sun,
Rola Saouaf,
Wensha Yang,
Debiao Li,
Zhaoyang Fan
Abstract:
Segmentation of multiple organs-at-risk (OARs) is essential for radiation therapy treatment planning and other clinical applications. We developed an Automated deep Learning-based Abdominal Multi-Organ segmentation (ALAMO) framework based on 2D U-net and a densely connected network structure with tailored design in data augmentation and training procedures such as deep connection, auxiliary superv…
▽ More
Segmentation of multiple organs-at-risk (OARs) is essential for radiation therapy treatment planning and other clinical applications. We developed an Automated deep Learning-based Abdominal Multi-Organ segmentation (ALAMO) framework based on 2D U-net and a densely connected network structure with tailored design in data augmentation and training procedures such as deep connection, auxiliary supervision, and multi-view. The model takes in multi-slice MR images and generates the output of segmentation results. Three-Tesla T1 VIBE (Volumetric Interpolated Breath-hold Examination) images of 102 subjects were collected and used in our study. Ten OARs were studied, including the liver, spleen, pancreas, left/right kidneys, stomach, duodenum, small intestine, spinal cord, and vertebral bodies. Two radiologists manually labeled and obtained the consensus contours as the ground-truth. In the complete cohort of 102, 20 samples were held out for independent testing, and the rest were used for training and validation. The performance was measured using volume overlapping and surface distance. The ALAMO framework generated segmentation labels in good agreement with the manual results. Specifically, among the 10 OARs, 9 achieved high Dice Similarity Coefficients (DSCs) in the range of 0.87-0.96, except for the duodenum with a DSC of 0.80. The inference completes within one minute for a 3D volume of 320x288x180. Overall, the ALAMO model matches the state-of-the-art performance. The proposed ALAMO framework allows for fully automated abdominal MR segmentation with high accuracy and low memory and computation time demands.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
Instant Ghost Imaging: Algorithm and On-chip Implementation
Authors:
Zhe Yang,
Wei-Xing Zhang,
Yi-Pu Liu,
Dong Ruan,
Jun-Lin Li
Abstract:
Ghost imaging (GI) is an imaging technique that uses the correlation between two light beams to reconstruct the image of an object. Conventional GI algorithms require large memory space to store the measured data and perform complicated offline calculations, limiting practical applications of GI. Here we develop an instant ghost imaging (IGI) technique with a differential algorithm and an implemen…
▽ More
Ghost imaging (GI) is an imaging technique that uses the correlation between two light beams to reconstruct the image of an object. Conventional GI algorithms require large memory space to store the measured data and perform complicated offline calculations, limiting practical applications of GI. Here we develop an instant ghost imaging (IGI) technique with a differential algorithm and an implemented high-speed on-chip IGI hardware system. This algorithm uses the signal between consecutive temporal measurements to reduce the memory requirements without degradation of image quality compared with conventional GI algorithms. The on-chip IGI system can immediately reconstruct the image once the measurement finishes; there is no need to rely on post-processing or offline reconstruction. This system can be developed into a realtime imaging system. These features make IGI a faster, cheaper, and more compact alternative to a conventional GI system and make it viable for practical applications of GI.
△ Less
Submitted 23 January, 2020; v1 submitted 4 December, 2019;
originally announced December 2019.
-
Manipulation of optomechanically induced transparency and absorption by indirectly coupling to an auxiliary cavity mode
Authors:
Guo-qing Qin,
Hong Yang,
Xuan Mao,
Jing-wei Wen,
Min Wang,
Dong Ruan,
Gui-lu Long
Abstract:
We theoretically study the optomechanically induced transparency (OMIT) and absorption(OMIA) phenomena in a single microcavity optomechanical system, assisted by an indirectly-coupledauxiliary cavity mode. We show that the interference effect between the two optical modes playsan important role and can be used to control the multiple-pathway induced destructive or construc-tive interference effect…
▽ More
We theoretically study the optomechanically induced transparency (OMIT) and absorption(OMIA) phenomena in a single microcavity optomechanical system, assisted by an indirectly-coupledauxiliary cavity mode. We show that the interference effect between the two optical modes playsan important role and can be used to control the multiple-pathway induced destructive or construc-tive interference effect. The three-pathway interference could induce an absorption dip within thetransparent window in the red sideband driving regime, while we can switch back and forth betweenOMIT and OMIA with the four-pathway interference. The conversion between the transparencypeak and absorption dip can be achieved by tuning the relative amplitude and phase of the multiplelight paths interference. Our system proposes a new platform to realize multiple pathways inducedtransparency and absorption in a single microcavity and a feasible way for realizing all-opticalinformation processing.
△ Less
Submitted 2 October, 2019; v1 submitted 1 October, 2019;
originally announced October 2019.
-
Linear Context Transform Block
Authors:
Dongsheng Ruan,
Jun Wen,
Nenggan Zheng,
Min Zheng
Abstract:
Squeeze-and-Excitation (SE) block presents a channel attention mechanism for modeling global context via explicitly capturing dependencies across channels. However, we are still far from understanding how the SE block works. In this work, we first revisit the SE block, and then present a detailed empirical study of the relationship between global context and attention distribution, based on which…
▽ More
Squeeze-and-Excitation (SE) block presents a channel attention mechanism for modeling global context via explicitly capturing dependencies across channels. However, we are still far from understanding how the SE block works. In this work, we first revisit the SE block, and then present a detailed empirical study of the relationship between global context and attention distribution, based on which we propose a simple yet effective module, called Linear Context Transform (LCT) block. We divide all channels into different groups and normalize the globally aggregated context features within each channel group, reducing the disturbance from irrelevant channels. Through linear transform of the normalized context features, we model global context for each channel independently. The LCT block is extremely lightweight and easy to be plugged into different backbone models while with negligible parameters and computational burden increase. Extensive experiments show that the LCT block outperforms the SE block in image classification task on the ImageNet and object detection/segmentation on the COCO dataset with different backbone models. Moreover, LCT yields consistent performance gains over existing state-of-the-art detection architectures, e.g., 1.5$\sim$1.7% AP$^{bbox}$ and 1.0$\sim$1.2% AP$^{mask}$ improvements on the COCO benchmark, irrespective of different baseline models of varied capacities. We hope our simple yet effective approach will shed some light on future research of attention-based models.
△ Less
Submitted 23 November, 2019; v1 submitted 6 September, 2019;
originally announced September 2019.
-
Generation of abdominal synthetic CTs from 0.35T MR images using generative adversarial networks for MR-only liver radiotherapy
Authors:
Jie Fu,
Kamal Singhrao,
Minsong Cao,
Victoria Yu,
Anand P. Santhanam,
Yingli Yang,
Minghao Guo,
Ann C. Raldow,
Dan Ruan,
John H. Lewis
Abstract:
Electron density maps must be accurately estimated to achieve valid dose calculation in MR-only radiotherapy. The goal of this study is to assess whether two deep learning models, the conditional generative adversarial network (cGAN) and the cycle-consistent generative adversarial network (cycleGAN), can generate accurate abdominal synthetic CT (sCT) images from 0.35T MR images for MR-only liver r…
▽ More
Electron density maps must be accurately estimated to achieve valid dose calculation in MR-only radiotherapy. The goal of this study is to assess whether two deep learning models, the conditional generative adversarial network (cGAN) and the cycle-consistent generative adversarial network (cycleGAN), can generate accurate abdominal synthetic CT (sCT) images from 0.35T MR images for MR-only liver radiotherapy. A retrospective study was performed using CT images and 0.35T MR images of 12 patients with liver (n=8) and non-liver abdominal (n=4) cancer. CT images were deformably registered to the corresponding MR images to generate deformed CT (dCT) images for treatment planning. Both cGAN and cycleGAN were trained using MR and dCT transverse slices. Four-fold cross-validation testing was conducted to generate sCT images for all patients. The HU prediction accuracy was evaluated by voxel-wise similarity metric between each dCT and sCT image for all 12 patients. dCT-based and sCT-based dose distributions were compared using gamma and dose-volume histogram (DVH) metric analysis for 8 liver patients. sCTcycleGAN achieved the average mean absolute error (MAE) of 94.1 HU, while sCTcGAN achieved 89.8 HU. In both models, the average gamma passing rates within all volumes of interest were higher than 95% using a 2%, 2 mm criterion, and 99% using a 3%, 3 mm criterion. The average differences in the mean dose and DVH metrics were within +/-0.6% for the planning target volume and within +/-0.15% for evaluated organs in both models. Results demonstrated that abdominal sCT images generated by both cGAN and cycleGAN achieved accurate dose calculation for 8 liver radiotherapy plans. sCTcGAN images had smaller average MAE and achieved better dose calculation accuracy than sCTcyleGAN images. More abdominal patients will be enrolled in the future to further evaluate two models.
△ Less
Submitted 13 August, 2019;
originally announced August 2019.
-
Fully Automated Pancreas Segmentation with Two-stage 3D Convolutional Neural Networks
Authors:
Ningning Zhao,
Nuo Tong,
Dan Ruan,
Ke Sheng
Abstract:
Due to the fact that pancreas is an abdominal organ with very large variations in shape and size, automatic and accurate pancreas segmentation can be challenging for medical image analysis. In this work, we proposed a fully automated two stage framework for pancreas segmentation based on convolutional neural networks (CNN). In the first stage, a U-Net is trained for the down-sampled 3D volume segm…
▽ More
Due to the fact that pancreas is an abdominal organ with very large variations in shape and size, automatic and accurate pancreas segmentation can be challenging for medical image analysis. In this work, we proposed a fully automated two stage framework for pancreas segmentation based on convolutional neural networks (CNN). In the first stage, a U-Net is trained for the down-sampled 3D volume segmentation. Then a candidate region covering the pancreas is extracted from the estimated labels. Motivated by the superior performance reported by renowned region based CNN, in the second stage, another 3D U-Net is trained on the candidate region generated in the first stage. We evaluated the performance of the proposed method on the NIH computed tomography (CT) dataset, and verified its superiority over other state-of-the-art 2D and 3D approaches for pancreas segmentation in terms of dice-sorensen coefficient (DSC) accuracy in testing. The mean DSC of the proposed method is 85.99%.
△ Less
Submitted 25 July, 2019; v1 submitted 4 June, 2019;
originally announced June 2019.
-
Arbitrary function resonance tuner of the optical microcavity with sub-MHz resolution
Authors:
Xu-Sheng Xu,
Hao Zhang,
Min Wang,
Dong Ruan,
Gui-Lu Long
Abstract:
The resonance frequency of an optical whispering gallery mode (WGM) microcavity is extremely important in its various applications. Many efforts have been made to fine tune this parameter. Here, we report the design and implementation of a function resonance tuner of an optical microcavity with resolution about 650 kHz (7 pm @ 1450 nm band), 20% of the optical WGM linewidth. A piezoelectric nano-p…
▽ More
The resonance frequency of an optical whispering gallery mode (WGM) microcavity is extremely important in its various applications. Many efforts have been made to fine tune this parameter. Here, we report the design and implementation of a function resonance tuner of an optical microcavity with resolution about 650 kHz (7 pm @ 1450 nm band), 20% of the optical WGM linewidth. A piezoelectric nano-positioner is used to mechanically compress the microsphere in its axial direction. The ultrafine frequency tuning is achieved benefitting from the much less changes in the axial direction than equatorial semiaxes of the microsphere and the sub-nanometer resolution of the nano-positioner. The tuning of the resonance can be made to an arbitrary function, dynamically, with near perfect accuracy. We have demonstrated the periodically tuning of resonance in the sine and sigmoid function respectively, both with over 99% fitting accuracy. This work expands the application of microresonators greatly, especially microspheres with ultrahigh quality factor, in multi-mode coupling system or time-floquet system.
△ Less
Submitted 9 April, 2019;
originally announced April 2019.
-
Symmetric vs. bosonic extension for bipartite states
Authors:
Youning Li,
Shilin Huang,
Dong Ruan,
Bei Zeng
Abstract:
A bipartite state $ρ^{AB}$ has a $k$-symmetric extension if there exists a $k+1$-partite state $ρ^{AB_1B_2\ldots B_k}$ with marginals $ρ^{AB_i}=ρ^{AB}, \forall i$. The $k$-symmetric extension is called bosonic if $ρ^{AB_1B_2\ldots B_k}$ is supported on the symmetric subspace of $B_1B_2\ldots B_k$. Understanding the structure of symmetric/bosonic extension has various applications in the theory of…
▽ More
A bipartite state $ρ^{AB}$ has a $k$-symmetric extension if there exists a $k+1$-partite state $ρ^{AB_1B_2\ldots B_k}$ with marginals $ρ^{AB_i}=ρ^{AB}, \forall i$. The $k$-symmetric extension is called bosonic if $ρ^{AB_1B_2\ldots B_k}$ is supported on the symmetric subspace of $B_1B_2\ldots B_k$. Understanding the structure of symmetric/bosonic extension has various applications in the theory of quantum entanglement, quantum key distribution and the quantum marginal problem. In particular, bosonic extension gives a tighter bound for the quantum marginal problem based on seperability. In general, it is known that a $ρ^{AB}$ admitting symmetric extension may not have bosonic extension. In this work, we show that when the dimension of the subsystem $B$ is $2$ (i.e. a qubit), $ρ^{AB}$ admits a $k$-symmetric extension if and only if it has a $k$-bosonic extension. Our result has an immediate application to the quantum marginal problem and indicates a special structure for qubit systems based on group representation theory.
△ Less
Submitted 14 September, 2018;
originally announced September 2018.
-
Precision measurements of $σ_{B}(e^+e^- \to K_{S}^{0}K^{\pm}π^{\mp})$ at center-of-mass energies between 3.8 and 4.6 GeV
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
M. Alekseev,
A. Amoroso,
F. F. An,
Q. An,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir
, et al. (423 additional authors not shown)
Abstract:
Using data samples collected by the BESIII detector operating at the BEPCII storage ring, we measure the $e^+e^- \to K_{S}^{0}K^{\pm}π^{\mp}$ Born cross sections at center-of-mass energies between 3.8 and 4.6\,GeV, corresponding to a luminosity of about 5.0~fb$^{-1}$. The results are compatible with the BABAR measurements, but with the precision significantly improved. A simple $1/s^n$ dependence…
▽ More
Using data samples collected by the BESIII detector operating at the BEPCII storage ring, we measure the $e^+e^- \to K_{S}^{0}K^{\pm}π^{\mp}$ Born cross sections at center-of-mass energies between 3.8 and 4.6\,GeV, corresponding to a luminosity of about 5.0~fb$^{-1}$. The results are compatible with the BABAR measurements, but with the precision significantly improved. A simple $1/s^n$ dependence for the continuum process can describe the measured cross sections, but a better fit is obtained by an additional resonance near 4.2\,GeV, which could be an excited charmonium or a charmonium-like state.
△ Less
Submitted 16 May, 2019; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Amplitude analysis of the $K_{S}K_{S}$ system produced in radiative $J/ψ$ decays
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir
, et al. (424 additional authors not shown)
Abstract:
An amplitude analysis of the $K_{S}K_{S}$ system produced in radiative $J/ψ$ decays is performed using the $(1310.6\pm7.0)\times10^{6}$ $J/ψ$ decays collected by the BESIII detector. Two approaches are presented. A mass-dependent analysis is performed by parameterizing the $K_{S}K_{S}$ invariant mass spectrum as a sum of Breit-Wigner line shapes. Additionally, a mass-independent analysis is perfor…
▽ More
An amplitude analysis of the $K_{S}K_{S}$ system produced in radiative $J/ψ$ decays is performed using the $(1310.6\pm7.0)\times10^{6}$ $J/ψ$ decays collected by the BESIII detector. Two approaches are presented. A mass-dependent analysis is performed by parameterizing the $K_{S}K_{S}$ invariant mass spectrum as a sum of Breit-Wigner line shapes. Additionally, a mass-independent analysis is performed to extract a piecewise function that describes the dynamics of the $K_{S}K_{S}$ system while making minimal assumptions about the properties and number of poles in the amplitude. The dominant amplitudes in the mass-dependent analysis include the $f_{0}(1710)$, $f_{0}(2200)$, and $f_{2}^\prime(1525)$. The mass-independent results, which are made available as input for further studies, are consistent with those of the mass-dependent analysis and are useful for a systematic study of hadronic interactions. The branching fraction of radiative $J/ψ$ decays to $K_{S}K_{S}$ is measured to be $(8.1 \pm 0.4) \times 10^{-4}$, where the uncertainty is systematic and the statistical uncertainty is negligible.
△ Less
Submitted 21 August, 2018;
originally announced August 2018.
-
Evidence of a resonant structure in the $e^+e^-\to π^+D^0D^{*-}$ cross section between 4.05 and 4.60 GeV
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir,
A. Calcaterra
, et al. (415 additional authors not shown)
Abstract:
The cross section of the process $e^+e^-\to π^+D^0D^{*-}$ for center-of-mass energies from 4.05 to 4.60~GeV is measured precisely using data samples collected with the BESIII detector operating at the BEPCII storage ring.
Two enhancements are clearly visible in the cross section around 4.23 and 4.40~GeV.
Using several models to describe the dressed cross section yields stable parameters for th…
▽ More
The cross section of the process $e^+e^-\to π^+D^0D^{*-}$ for center-of-mass energies from 4.05 to 4.60~GeV is measured precisely using data samples collected with the BESIII detector operating at the BEPCII storage ring.
Two enhancements are clearly visible in the cross section around 4.23 and 4.40~GeV.
Using several models to describe the dressed cross section yields stable parameters for the first enhancement, which has a mass of $4228.6 \pm 4.1 \pm 6.3 \un{MeV}/c^2$ and a width of $77.0 \pm 6.8 \pm 6.3 \un{MeV}$, where the first uncertainties are statistical and the second ones are systematic.
Our resonant mass is consistent with previous observations of the $Y(4220)$ state and the theoretical prediction of a $D\bar{D}_1(2420)$ molecule.
This result is the first observation of $Y(4220)$ associated with an open-charm final state.
Fits with three resonance functions with additional $Y(4260)$, $Y(4320)$, $Y(4360)$, $ψ(4415)$, or a new resonance, do not show significant contributions from either of these resonances. The second enhancement is not from a single known resonance. It could contain contributions from $ψ(4415)$ and other resonances, and a detailed amplitude analysis is required to better understand this enhancement.
△ Less
Submitted 2 April, 2019; v1 submitted 8 August, 2018;
originally announced August 2018.
-
Measurement of the phase between strong and electromagnetic amplitudes of $J/ψ$ decays
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir
, et al. (422 additional authors not shown)
Abstract:
Using 16 energy points of $e^{+}e^{-}$ annihilation data collected in the vicinity of the $J/ψ$ resonance with the BESIII detector and with a total integrated luminosity of around 100 pb$^{-1}$, we study the relative phase between the strong and electromagnetic amplitudes of $J/ψ$ decays. The relative phase between $Jψ$ electromagnetic decay and the continuum process ($e^{+}e^{-}$ annihilation wit…
▽ More
Using 16 energy points of $e^{+}e^{-}$ annihilation data collected in the vicinity of the $J/ψ$ resonance with the BESIII detector and with a total integrated luminosity of around 100 pb$^{-1}$, we study the relative phase between the strong and electromagnetic amplitudes of $J/ψ$ decays. The relative phase between $Jψ$ electromagnetic decay and the continuum process ($e^{+}e^{-}$ annihilation without the $J/ψ$ resonance) is confirmed to be zero by studying the cross section lineshape of $μ^{+}μ^{-}$ production. The relative phase between $J/ψ$ strong and electromagnetic decays is then measured to be $(84.9\pm3.6)^\circ$ or $(-84.7\pm3.1)^\circ$ for the $2(π^{+}π^{-})π^{0}$ final state by investigating the interference pattern between the $J/ψ$ decay and the continuum process. This is the first measurement of the relative phase between $J/ψ$ strong and electromagnetic decays into a multihadron final state using the lineshape of the production cross section. We also study the production lineshape of the multihadron final state $ηπ^{+}π^{-}$ with $η\toπ^{+}π^{-}π^{0}$, which provides additional information about the phase between the $J/ψ$ electromagnetic decay amplitude and the continuum process. Additionally, the branching fraction of $J/ψ\to 2(π^{+}π^{-})π^{0}$ is measured to be $(4.73\pm0.44)\%$ or $(4.85\pm0.45)\%$, and the branching fraction of $J/ψ\toηπ^{+}π^{-}$ is measured to be $(3.78\pm0.68)\times10^{-4}$. Both of them are consistent with the world average values. The quoted uncertainties include both statistical and systematic uncertainties, which are mainly caused by the low statistics.
△ Less
Submitted 2 April, 2019; v1 submitted 6 August, 2018;
originally announced August 2018.
-
Measurement of absolute branching fraction of the inclusive decay $Λ_{c}^{+} \to Λ+ X$
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
M. Alekseev,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (426 additional authors not shown)
Abstract:
Based on an $e^+e^-$ collision data sample corresponding to an integrated luminosity of 567$\,\rm{pb}^{-1}$ taken at the center-of-mass energy of $\sqrt{s} = 4.6$ GeV with the BESIII detector, we measure the absolute branching fraction of the inclusive decay $Λ_{c}^{+} \to Λ+ X$ to be $\mathcal{B}(Λ_{c}^{+} \to Λ+ X)=(38.2^{+2.8}_{-2.2}\pm0.8)\%$ using the double-tag method, where $X$ refers to an…
▽ More
Based on an $e^+e^-$ collision data sample corresponding to an integrated luminosity of 567$\,\rm{pb}^{-1}$ taken at the center-of-mass energy of $\sqrt{s} = 4.6$ GeV with the BESIII detector, we measure the absolute branching fraction of the inclusive decay $Λ_{c}^{+} \to Λ+ X$ to be $\mathcal{B}(Λ_{c}^{+} \to Λ+ X)=(38.2^{+2.8}_{-2.2}\pm0.8)\%$ using the double-tag method, where $X$ refers to any possible final state particles. In addition, we search for direct CP violation in the charge asymmetry of this inclusive decay for the first time, and obtain $\mathcal{A}_{CP} \equiv \frac{\mathcal{B}(Λ_{c}^{+} \to Λ+ X)-\mathcal{B}(\barΛ_{c}^{-} \to \barΛ + X)}{\mathcal{B}(Λ_{c}^{+} \to Λ+ X)+\mathcal{B}(\barΛ_{c}^{-} \to \barΛ + X)} = (2.1^{+7.0}_{-6.6}\pm1.4)\%$, a statistically limited result with no evidence of CP violation.
△ Less
Submitted 15 March, 2018;
originally announced March 2018.
-
Study of the decays $D^+\rightarrowη^{(\prime)} e^+ν_{e}$
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir,
A. Calcaterra
, et al. (422 additional authors not shown)
Abstract:
The charm semileptonic decays $D^+\toηe^+ν_{e}$ and $D^+\toη'e^+ν_{e}$ are studied with a sample of $e^+e^-$ collision data corresponding to an integrated luminosity of 2.93 fb$^{-1}$ collected at $\sqrt{s}$ = 3.773 GeV with the BESIII detector. We measure the branching fractions for $D^+\toηe^+ν_{e}$ to be $(10.74\pm0.81\pm0.51)\times10^{-4}$, and for $D^+\toη'e^+ν_{e}$ to be…
▽ More
The charm semileptonic decays $D^+\toηe^+ν_{e}$ and $D^+\toη'e^+ν_{e}$ are studied with a sample of $e^+e^-$ collision data corresponding to an integrated luminosity of 2.93 fb$^{-1}$ collected at $\sqrt{s}$ = 3.773 GeV with the BESIII detector. We measure the branching fractions for $D^+\toηe^+ν_{e}$ to be $(10.74\pm0.81\pm0.51)\times10^{-4}$, and for $D^+\toη'e^+ν_{e}$ to be $(1.91\pm0.51\pm0.13)\times10^{-4}$, where the uncertainties are statistical and systematic, respectively. In addition, we perform a measurement of the form factor in the decay $D^+\toηe^+ν_{e}$. All the results are consistent with those obtained by the CLEO-c experiment.
△ Less
Submitted 14 March, 2018;
originally announced March 2018.
-
Search for Baryon and Lepton Number Violation in $J/ψ\toΛ_c^+e^-+c.c.$
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir
, et al. (427 additional authors not shown)
Abstract:
Using $1.31\times10^9$ $J/ψ$ events collected by the BESIII detector at the Beijing Electron Positron Collider, we search for the process $J/ψ\toΛ_c^+e^-+c.c.$ for the first time. In this process, both baryon and lepton number conservation is violated. No signal is found and the upper limit on the branching fraction $\mathcal{B}(J/ψ\toΛ_c^+e^-+c.c.)$ is set to be $6.9\times10^{-8}$ at the 90\% Con…
▽ More
Using $1.31\times10^9$ $J/ψ$ events collected by the BESIII detector at the Beijing Electron Positron Collider, we search for the process $J/ψ\toΛ_c^+e^-+c.c.$ for the first time. In this process, both baryon and lepton number conservation is violated. No signal is found and the upper limit on the branching fraction $\mathcal{B}(J/ψ\toΛ_c^+e^-+c.c.)$ is set to be $6.9\times10^{-8}$ at the 90\% Confidence Level.
△ Less
Submitted 13 March, 2018;
originally announced March 2018.
-
Measurement of the Integrated Luminosities of Cross-section Scan Data Samples Around the $ψ(3770)$ Mass Region
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
M. Alekseev,
A. Amoroso,
F. F. An,
Q. An,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
K. Begzsuren,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir
, et al. (439 additional authors not shown)
Abstract:
To investigate the nature of the $ψ(3770)$ resonance and to measure the cross section for $e^+e^- \to D\bar{D}$, a cross-section scan data sample, distributed among 41 center-of-mass energy points from 3.73 to 3.89~GeV, was taken with the BESIII detector operated at the BEPCII collider in the year 2010. By analyzing the large angle Bhabha scattering events, we measure the integrated luminosity of…
▽ More
To investigate the nature of the $ψ(3770)$ resonance and to measure the cross section for $e^+e^- \to D\bar{D}$, a cross-section scan data sample, distributed among 41 center-of-mass energy points from 3.73 to 3.89~GeV, was taken with the BESIII detector operated at the BEPCII collider in the year 2010. By analyzing the large angle Bhabha scattering events, we measure the integrated luminosity of the data sample at each center-of-mass energy point. The total integrated luminosity of the data sample is $76.16\pm0.04\pm0.61$~pb$^{-1}$, where the first uncertainty is statistical and the second systematic.
△ Less
Submitted 17 May, 2018; v1 submitted 10 March, 2018;
originally announced March 2018.
-
Male pelvic synthetic CT generation from T1-weighted MRI using 2D and 3D convolutional neural networks
Authors:
Jie Fu,
Yingli Yang,
Kamal Singhrao,
Dan Ruan,
Daniel A. Low,
John H. Lewis
Abstract:
To achieve magnetic resonance (MR)-only radiotherapy, a method needs to be employed to estimate a synthetic CT (sCT) for generating electron density maps and patient positioning reference images. We investigated 2D and 3D convolutional neural network (CNN) methods to generate a male pelvic sCT using a T1-weighted MR image. A retrospective study was performed using CTs and T1-weighted MR images of…
▽ More
To achieve magnetic resonance (MR)-only radiotherapy, a method needs to be employed to estimate a synthetic CT (sCT) for generating electron density maps and patient positioning reference images. We investigated 2D and 3D convolutional neural network (CNN) methods to generate a male pelvic sCT using a T1-weighted MR image. A retrospective study was performed using CTs and T1-weighted MR images of 20 prostate cancer patients. The proposed 2D CNN model, which contained 27 convolutional layers, was modified from the SegNet for better performance. 3D version of the CNN model was also developed. Both CNN models were trained from scratch to map intensities of T1-weighted MR images to CT Hounsfield Unit (HU) values. Each sCT was generated in a five-fold-cross-validation framework and compared with the corresponding CT using voxel-wise mean absolute error (MAE), and dice similarity coefficient (DSC), recall, and precision for bony structures. Wilcoxon signed-rank tests were performed to evaluate the differences between the both models. The MAE averaged across all patients were 40.5 $\pm$ 5.4 HU and 37.6 $\pm$ 5.1 HU for the 2D and 3D CNN models, respectively. The DSC, recall, and precision of the bony structures were 0.81 $\pm$ 0.04, 0.85 $\pm$ 0.04, and 0.77 $\pm$ 0.09 for the 2D CNN model, and 0.82 $\pm$ 0.04, 0.84 $\pm$ 0.04, and 0.80 $\pm$ 0.08 for the 3D CNN model, respectively. P values of the Wilcoxon signed-rank tests were less than 0.05 except for recall, which was 0.6. The 2D and 3D CNN models generated accurate pelvic sCTs for the 20 patients using T1-weighted MR images. The evaluation metrics and statistical tests indicated that the 3D model was able to generate sCTs with better MAE, bone DSC, and bone precision. The accuracy of the dose calculation and patient positioning using generated sCTs will be tested and compared for the two models in the future.
△ Less
Submitted 28 February, 2018;
originally announced March 2018.
-
Study of two-photon decays of pseudoscalar mesons via $J/ψ$ radiative decays
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
Y. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai
, et al. (426 additional authors not shown)
Abstract:
Using a sample of $4.48\times10^{8}$ $ψ(3686)$ events collected with the BESIII detector at the BEPCII collider, we study the two-photon decays of the pseudoscalar mesons $π^0$, $η$, $η^\prime$, $η(1405)$, $η(1475)$, $η(1760)$, and $X(1835)$ in $J/ψ$ radiative decays using $ψ(3686)\toπ^{+}π^{-}J/ψ$ events. The $π^0$, $η$ and $η^\prime$ mesons are clearly observed in the two-photon mass spectra, an…
▽ More
Using a sample of $4.48\times10^{8}$ $ψ(3686)$ events collected with the BESIII detector at the BEPCII collider, we study the two-photon decays of the pseudoscalar mesons $π^0$, $η$, $η^\prime$, $η(1405)$, $η(1475)$, $η(1760)$, and $X(1835)$ in $J/ψ$ radiative decays using $ψ(3686)\toπ^{+}π^{-}J/ψ$ events. The $π^0$, $η$ and $η^\prime$ mesons are clearly observed in the two-photon mass spectra, and the branching fractions are determined to be $B(J/ψ\toγπ^{0}\to3γ)=(3.57\pm0.12\pm0.16)\times10^{-5}$, $B(J/ψ\toγη\to3γ)=(4.42\pm0.04\pm0.18)\times10^{-4}$, and $B(J/ψ\toγη'\to3γ)=(1.26\pm0.02\pm0.05)\times10^{-4}$, where the first errors are statistical and the second systematic. No clear signal for $η(1405)$, $η(1475)$, $η(1760)$ or $X(1835)$ is observed in the two-photon mass spectra, and upper limits at the $90\%$ confidence level on the product branching fractions are obtained.
△ Less
Submitted 27 February, 2018;
originally announced February 2018.
-
Experimental realization of noise-induced adiabaticity in nuclear magnetic resonance
Authors:
B X Wang,
T Xin,
X Y Kong,
Sh J Wei,
D Ruan,
G L Long
Abstract:
The adiabatic evolution is the dynamics of an instantaneous eigenstate of a slowly varing Hamiltonian. Recently, an interesting phenomenon shows up that white noises can enhance and even induce adiabaticity, which is in contrast to previous perception that environmental noises always modify and even ruin a designed adiabatic passage. We experimentally realized a noise-induced adiabaticity in a nuc…
▽ More
The adiabatic evolution is the dynamics of an instantaneous eigenstate of a slowly varing Hamiltonian. Recently, an interesting phenomenon shows up that white noises can enhance and even induce adiabaticity, which is in contrast to previous perception that environmental noises always modify and even ruin a designed adiabatic passage. We experimentally realized a noise-induced adiabaticity in a nuclear magnetic resonance system. Adiabatic Hadamard gate and entangled state are demonstrated. The effect of noise on adiabaticity is experimentally exhibited and compared with the noise-free process. We utilized a noise-injected method, which can be applied to other quantum systems.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
Observation of $e^{+}e^{-} \rightarrow K\bar{K}J/ψ$ at center-of-mass energies from 4.189 to 4.600 GeV
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir
, et al. (420 additional authors not shown)
Abstract:
We investigate the process $e^{+}e^{-} \rightarrow K\bar{K}J/ψ$ at center-of-mass energies from 4.189 to 4.600 GeV using 4.7 fb$^{-1}$ of data collected by the BESIII detector at the BEPCII collider. The Born cross sections for the reactions $e^{+}e^{-} \rightarrow K^{+}K^{-}J/ψ$ and $K_{S}^{0} K_{S}^{0} J/ψ$ are measured as a function of center-of-mass energy. The energy dependence of the cross s…
▽ More
We investigate the process $e^{+}e^{-} \rightarrow K\bar{K}J/ψ$ at center-of-mass energies from 4.189 to 4.600 GeV using 4.7 fb$^{-1}$ of data collected by the BESIII detector at the BEPCII collider. The Born cross sections for the reactions $e^{+}e^{-} \rightarrow K^{+}K^{-}J/ψ$ and $K_{S}^{0} K_{S}^{0} J/ψ$ are measured as a function of center-of-mass energy. The energy dependence of the cross section for $e^{+}e^{-} \rightarrow K^{+}K^{-}J/ψ$ is shown to differ from that for $π^{+}π^{-}J/ψ$ in the region around the $Y(4260)$. In addition, there is evidence for a structure around 4.5 GeV in the $e^{+}e^{-} \rightarrow K^{+}K^{-}J/ψ$ cross section that is not present in $π^{+}π^{-}J/ψ$.
△ Less
Submitted 4 February, 2018;
originally announced February 2018.
-
Quantum simulation of photosynthetic energy transfer
Authors:
Bi-Xue Wang,
Ming-Jie Tao,
Qing Ai,
Tao Xin,
Neill Lambert,
Dong Ruan,
Yuan-Chung Cheng,
Franco Nori,
Fu-Guo Deng,
Gui-Lu Long
Abstract:
Near-unity energy transfer efficiency has been widely observed in natural photosynthetic complexes. This phenomenon has attracted broad interest from different fields, such as physics, biology, chemistry and material science, as it may offer valuable insights into efficient solar-energy harvesting. Recently, quantum coherent effects have been discovered in photosynthetic light harvesting, and thei…
▽ More
Near-unity energy transfer efficiency has been widely observed in natural photosynthetic complexes. This phenomenon has attracted broad interest from different fields, such as physics, biology, chemistry and material science, as it may offer valuable insights into efficient solar-energy harvesting. Recently, quantum coherent effects have been discovered in photosynthetic light harvesting, and their potential role on energy transfer has seen heated debate. Here, we perform an experimental quantum simulation of photosynthetic energy transfer using nuclear magnetic resonance (NMR). We show that an N- chromophore photosynthetic complex, with arbitrary structure and bath spectral density, can be effectively simulated by a system with log2 N qubits. The computational cost of simulating such a system with a theoretical tool, like the hierarchical equation of motion, which is exponential in N, can be potentially reduced to requiring a just polynomial number of qubits N using NMR quantum simulation. The benefits of performing such quantum simulation in NMR are even greater when the spectral density is complex, as in natural photosynthetic complexes. These findings may shed light on quantum coherence in energy transfer and help to provide design principles for efficient artificial light harvesting.
△ Less
Submitted 30 January, 2018; v1 submitted 29 January, 2018;
originally announced January 2018.
-
Study of $η(1475)$ and $X(1835)$ in radiative $J/ψ$ decays to $γφ$
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
O. Albayrak,
M. Albrecht,
M. Alekseev,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere
, et al. (410 additional authors not shown)
Abstract:
The decay $J/ψ\rightarrow γγφ$ is studied using a sample of $1.31 \times10^{9}$ $J/ψ$ events collected with the BESIII detector. Two structures around 1475 MeV/c$^2$ and 1835 MeV/c$^2$ are observed in the $γφ$ invariant mass spectrum for the first time. With a fit on the $γφ$ invariant mass, which takes into account the interference between the two structures, and a simple analysis of the angular…
▽ More
The decay $J/ψ\rightarrow γγφ$ is studied using a sample of $1.31 \times10^{9}$ $J/ψ$ events collected with the BESIII detector. Two structures around 1475 MeV/c$^2$ and 1835 MeV/c$^2$ are observed in the $γφ$ invariant mass spectrum for the first time. With a fit on the $γφ$ invariant mass, which takes into account the interference between the two structures, and a simple analysis of the angular distribution, the structure around 1475 MeV/c$^2$ is found to favor an assignment as the $η(1475)$ and the mass and width for the structure around 1835 MeV/c$^2$ are consistent with the $X(1835)$. The statistical significances of the two structures are $13.5 σ$ and $6.3 σ$, respectively. The results indicate that both $η(1475)$ and $X(1835)$ contain a sizeable $s\bar{s}$ component.
△ Less
Submitted 6 January, 2018;
originally announced January 2018.
-
Quantum Spacetime on a Quantum Simulator
Authors:
Keren Li,
Youning Li,
Muxin Han,
Sirui Lu,
Jie Zhou,
Dong Ruan,
Guilu Long,
Yidun Wan,
Dawei Lu,
Bei Zeng,
Raymond Laflamme
Abstract:
We experimentally simulate the spin networks -- a fundamental description of quantum spacetime at the Planck level. We achieve this by simulating quantum tetrahedra and their interactions. The tensor product of these quantum tetrahedra comprises spin networks. In this initial attempt to study quantum spacetime by quantum information processing, on a four-qubit nuclear magnetic resonance quantum si…
▽ More
We experimentally simulate the spin networks -- a fundamental description of quantum spacetime at the Planck level. We achieve this by simulating quantum tetrahedra and their interactions. The tensor product of these quantum tetrahedra comprises spin networks. In this initial attempt to study quantum spacetime by quantum information processing, on a four-qubit nuclear magnetic resonance quantum simulator, we simulate the basic module -- comprising five quantum tetrahedra -- of the interactions of quantum spacetime. By measuring the geometric properties on the corresponding quantum tetrahedra and simulate their interactions, our experiment serves as the basic module that represents the Feynman diagram vertex in the spin-network formulation of quantum spacetime.
△ Less
Submitted 22 December, 2017;
originally announced December 2017.
-
Precision Study of $η^\prime\rightarrowγπ^+π^-$ Decay Dynamics
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
S. Ahmed,
X. C. Ai,
O. Albayrak,
M. Albrecht,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (413 additional authors not shown)
Abstract:
Using a low background data sample of $9.7\times10^{5}$ $Jψ\rightarrowγη^\prime$, $η^\prime\rightarrowγπ^+π^-$ events, which are 2 orders of magnitude larger than those from the previous experiments, recorded with the BESIII detector at BEPCII, the decay dynamics of $η^\prime\rightarrowγπ^+π^-$ are studied with both model-dependent and model-independent approaches. The contributions of $ω$ and the…
▽ More
Using a low background data sample of $9.7\times10^{5}$ $Jψ\rightarrowγη^\prime$, $η^\prime\rightarrowγπ^+π^-$ events, which are 2 orders of magnitude larger than those from the previous experiments, recorded with the BESIII detector at BEPCII, the decay dynamics of $η^\prime\rightarrowγπ^+π^-$ are studied with both model-dependent and model-independent approaches. The contributions of $ω$ and the $ρ(770)-ω$ interference are observed for the first time in the decays $η^\prime\rightarrowγπ^+π^-$ in both approaches. Additionally, a contribution from the box anomaly or the $ρ(1450)$ resonance is required in the model-dependent approach, while the process specific part of the decay amplitude is determined in the model-independent approach.
△ Less
Submitted 19 June, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Measurement of the absolute branching fraction of $D_{s0}^{*\pm}(2317)\to π^0 D_{s}^{\pm}$
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bet toni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir,
A. Calcaterra
, et al. (409 additional authors not shown)
Abstract:
The process $e^+ e^- \to D_{s}^{*+} D_{s0}^{*-}(2317)+c.c.$ is observed for the first time with the data sample of 567~pb$^{-1}$ collected with the BESIII detector operating at the BEPCII collider at a center-of-mass energy $\sqrt{s} = 4.6$~GeV. The statistical significance of the $D_{s0}^{*-}(2317)$ signal is $5.8σ$ and the mass is measured to be ($2318.3\pm 1.2\pm 1.2$)~MeV/$c^{2}$. The absolute…
▽ More
The process $e^+ e^- \to D_{s}^{*+} D_{s0}^{*-}(2317)+c.c.$ is observed for the first time with the data sample of 567~pb$^{-1}$ collected with the BESIII detector operating at the BEPCII collider at a center-of-mass energy $\sqrt{s} = 4.6$~GeV. The statistical significance of the $D_{s0}^{*-}(2317)$ signal is $5.8σ$ and the mass is measured to be ($2318.3\pm 1.2\pm 1.2$)~MeV/$c^{2}$. The absolute branching fraction $\mathcal{B}(D_{s0}^{*-}(2317)\to π^0 D_{s}^{-})$ is measured as $1.00^{+0.00}_{-0.14}\pm 0.14$ for the first time. The uncertainties are statistical and systematic, respectively.
△ Less
Submitted 22 November, 2017;
originally announced November 2017.
-
Single phonon source based on a giant acoustic nonlinear effect
Authors:
Kang Cai,
Zi-wen Pan,
Rui-xia Wang,
Dong Ruan,
Zhang-qi Yin,
Gui-lu Long
Abstract:
We propose a single phonon source based on nitrogen-vacancy (NV) centers, which are located in a diamond phononic crystal resonator. The strain in the lattice would induce the coupling between the NV centers and the phonon mode. The strong coupling between the excited state of the NV centers and the phonon is realized by adding an optical laser driving. This four level NV centers system exhibits t…
▽ More
We propose a single phonon source based on nitrogen-vacancy (NV) centers, which are located in a diamond phononic crystal resonator. The strain in the lattice would induce the coupling between the NV centers and the phonon mode. The strong coupling between the excited state of the NV centers and the phonon is realized by adding an optical laser driving. This four level NV centers system exhibits the coherent population trapping (CPT), and yields giant resonantly enhanced acoustic nonlinearities, with zero linear susceptibility. Based on this nonlinearity, the single phonon source can be realized. We numerically calculate $g^{(2)}(0)$ of the single phonon source. We discuss the effects of the thermal noise and the external driving strength.
△ Less
Submitted 18 November, 2017;
originally announced November 2017.
-
Measurement of $e^{+}e^{-} \to π^{0}π^{0}ψ(3686)$ at $\sqrt{s}$ from 4.009 to 4.600 GeV and observation of a neutral charmoniumlike structure
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir,
A. Calcaterra
, et al. (414 additional authors not shown)
Abstract:
Using $e^{+}e^{-}$ collision data collected with the BESIII detector at the BEPCII collider corresponding to an integrated luminosity of 5.2 $fb^{-1}$ at center-of-mass energies ($\sqrt{s}$) from 4.009 to 4.600 GeV, the process $e^{+}e^{-} \to π^{0} π^{0}ψ(3686)$ is studied for the first time. The corresponding Born cross sections are measured and found to be half of those of the reaction…
▽ More
Using $e^{+}e^{-}$ collision data collected with the BESIII detector at the BEPCII collider corresponding to an integrated luminosity of 5.2 $fb^{-1}$ at center-of-mass energies ($\sqrt{s}$) from 4.009 to 4.600 GeV, the process $e^{+}e^{-} \to π^{0} π^{0}ψ(3686)$ is studied for the first time. The corresponding Born cross sections are measured and found to be half of those of the reaction $e^{+}e^{-} \to π^{+}π^{-}ψ(3686)$. This is consistent with the expectation from isospin symmetry. Furthermore, the Dalitz plots for $π^{0}π^{0}ψ(3686)$ are accordant with those of $π^{+}π^{-}ψ(3686)$ at all energy points, and a neutral analogue to the structure in $π^\pm ψ(3686)$ around 4040 MeV/$c^{2}$ first observed at $\sqrt{s}$=4.416 GeV is observed in the isospin neutral mode at the same energy.
△ Less
Submitted 29 October, 2017;
originally announced October 2017.
-
Fraction-variant beam orientation optimization for non-coplanar IMRT
Authors:
Daniel O'Connor,
Dan Nguyen,
Dan Ruan,
Victoria Yu,
Ke Sheng
Abstract:
Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously optimizes non-coplanar beam angles for all fractions, yielding a fraction-variant (FV) treatment plan. Beam angles are selected by solving a multi-fraction FMO problem…
▽ More
Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously optimizes non-coplanar beam angles for all fractions, yielding a fraction-variant (FV) treatment plan. Beam angles are selected by solving a multi-fraction FMO problem involving 500-700 candidate beams per fraction, with an additional group sparsity term that encourages most candidate beams to be inactive. The optimization problem is solved using the Fast Iterative Shrinkage-Thresholding Algorithm. Our FV BOO algorithm is used to create non-coplanar, five-fraction treatment plans for prostate and lung cases, as well as a non-coplanar 30-fraction plan for a head and neck case. A homogeneous PTV dose coverage is maintained in all fractions. The treatment plans are compared with fraction-invariant plans that use a fixed set of beam angles for all fractions. The FV plans reduced mean and max OAR dose on average by 3.3% and 3.7% of the prescription dose, respectively. Notably, mean OAR dose was reduced by 14.3% of prescription dose (rectum), 11.6% (penile bulb), 10.7% (seminal vesicle), 5.5% (right femur), 3.5% (bladder), 4.0% (normal left lung), 15.5% (cochleas), and 5.2% (chiasm). Max OAR dose was reduced by 14.9% of prescription dose (right femur), 8.2% (penile bulb), 12.7% (prox. bronchus), 4.1% (normal left lung), 15.2% (cochleas), 10.1% (orbits), 9.1% (chiasm), 8.7% (brainstem), and 7.1% (parotids). Meanwhile, PTV homogeneity defined as D95/D5 improved from .95 to .98 (prostate case) and from .94 to .97 (lung case), and remained constant for the head and neck case. Moreover, the FV plans are dosimetrically similar to conventional plans that use twice as many beams per fraction. Thus, FV BOO offers the potential to reduce delivery time for non-coplanar IMRT.
△ Less
Submitted 15 October, 2017;
originally announced October 2017.
-
Search for the rare decays $J/ψ\to D^{0} e^{+}e^{-} +c.c.$ and $ψ(3686) \to D^{0} e^{+}e^{-} +c.c.$
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
M. Albrecht,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai,
X. Cai,
O. Cakir,
A. Calcaterra
, et al. (414 additional authors not shown)
Abstract:
Using the data samples of $(1310.6\pm7.2 )\times 10^{6}$ $J/ψ$ events and $(448.1\pm2.9)\times 10^{6}$ $ψ(3686)$ events collected with the BESIII detector, we search for the rare decays $J/ψ\to D^{0} e^{+}e^{-} +c.c.$ and $ψ(3686) \to D^{0} e^{+}e^{-} +c.c.$. No significant signals are observed and the corresponding upper limits on the branching fractions at the $90\%$ confidence level are determi…
▽ More
Using the data samples of $(1310.6\pm7.2 )\times 10^{6}$ $J/ψ$ events and $(448.1\pm2.9)\times 10^{6}$ $ψ(3686)$ events collected with the BESIII detector, we search for the rare decays $J/ψ\to D^{0} e^{+}e^{-} +c.c.$ and $ψ(3686) \to D^{0} e^{+}e^{-} +c.c.$. No significant signals are observed and the corresponding upper limits on the branching fractions at the $90\%$ confidence level are determined to be $Br(J/ψ\to D^{0} e^{+}e^{-} +c.c.)< 8.5\times 10^{-8}$ and $Br (ψ(3686) \to D^{0} e^{+}e^{-} +c.c.)<1.4\times 10^{-7}$, respectively. Our limit on $Br(J/ψ\to D^{0} e^{+}e^{-} +c.c.)$ is more stringent by two orders of magnitude than the previous results, and the $Br(ψ(3686) \to D^{0} e^{+}e^{-} +c.c.)$ is measured for the first time.
△ Less
Submitted 6 October, 2017;
originally announced October 2017.