-
NoX: a Compact Open-Source RISC-V Processor for Multi-Processor Systems-on-Chip
Authors:
Anderson I. Silva,
Altamiro Susin,
Fernanda L. Kastensmidt,
Antonio Carlos S. Beck,
Jose Rodrigo Azambuja
Abstract:
IoT applications are one of the driving forces in making systems energy and power-efficient, given their resource constraints. However, because of security, latency, and transmission, we advocate for local computing through multi-processor systems-on-chip (MPSoCs) for edge computing. The RISC-V ISA has grown in academia and industry due to its flexibility. Still, available open-source cores cannot…
▽ More
IoT applications are one of the driving forces in making systems energy and power-efficient, given their resource constraints. However, because of security, latency, and transmission, we advocate for local computing through multi-processor systems-on-chip (MPSoCs) for edge computing. The RISC-V ISA has grown in academia and industry due to its flexibility. Still, available open-source cores cannot be seamlessly integrated into MPSoCs for a fast time to market. This paper presents NoX, a compact open-source plug-and-play 32-bit RISC-V core designed in System Verilog for efficient data processing in MPSoCs. NoX has a 4-stage single-issue in-order pipeline with full bypass, providing an efficient resource-constrained architecture. Compared to industry and academia resource-constrained RISC-V cores, NoX offers a better resource usage and performance trade-off.
△ Less
Submitted 25 June, 2024;
originally announced June 2024.
-
Multimodal wearable EEG, EMG and accelerometry measurements improve the accuracy of tonic-clonic seizure detection in-hospital
Authors:
Jingwei Zhang,
Lauren Swinnen,
Christos Chatzichristos,
Victoria Broux,
Renee Proost,
Katrien Jansen,
Benno Mahler,
Nicolas Zabler,
Nino Epitashvilli,
Matthias Dümpelmann,
Andreas Schulze-Bonhage,
Elisabeth Schriewer,
Ummahan Ermis,
Stefan Wolking,
Florian Linke,
Yvonne Weber,
Mkael Symmonds,
Arjune Sen,
Andrea Biondi,
Mark P. Richardson,
Abuhaiba Sulaiman I,
Ana Isabel Silva,
Francisco Sales,
Gergely Vértes,
Wim Van Paesschen
, et al. (1 additional authors not shown)
Abstract:
Objective: Most current wearable tonic-clonic seizure (TCS) detection systems are based on extra-cerebral signals, such as electromyography (EMG) or accelerometry (ACC). Although many of these devices show good sensitivity in seizure detection, their false positive rates (FPR) are still relatively high. Wearable EEG may improve performance; however, studies investigating this remain scarce. This p…
▽ More
Objective: Most current wearable tonic-clonic seizure (TCS) detection systems are based on extra-cerebral signals, such as electromyography (EMG) or accelerometry (ACC). Although many of these devices show good sensitivity in seizure detection, their false positive rates (FPR) are still relatively high. Wearable EEG may improve performance; however, studies investigating this remain scarce. This paper aims 1) to investigate the possibility of detecting TCSs with a behind-the-ear, two-channel wearable EEG, and 2) to evaluate the added value of wearable EEG to other non-EEG modalities in multimodal TCS detection. Method: We included 27 participants with a total of 44 TCSs from the European multicenter study SeizeIT2. The multimodal wearable detection system Sensor Dot (Byteflies) was used to measure two-channel, behind-the-ear EEG, EMG, electrocardiography (ECG), ACC and gyroscope (GYR). First, we evaluated automatic unimodal detection of TCSs, using performance metrics such as sensitivity, precision, FPR and F1-score. Secondly, we fused the different modalities and again assessed performance. Algorithm-labeled segments were then provided to a neurologist and a wearable data expert, who reviewed and annotated the true positive TCSs, and discarded false positives (FPs). Results: Wearable EEG outperformed the other modalities in unimodal TCS detection by achieving a sensitivity of 100.0% and a FPR of 10.3/24h (compared to 97.7% sensitivity and 30.9/24h FPR for EMG; 95.5% sensitivity and 13.9 FPR for ACC). The combination of wearable EEG and EMG achieved overall the most clinically useful performance in offline TCS detection with a sensitivity of 97.7%, a FPR of 0.4/24 h, a precision of 43.0%, and a F1-score of 59.7%. Subsequent visual review of the automated detections resulted in maximal sensitivity and zero FPs.
△ Less
Submitted 19 March, 2024;
originally announced March 2024.
-
Physical conditions in QSO absorbers from fine-structure absorption lines
Authors:
A. I. Silva,
S. M. Viegas
Abstract:
We calculate theoretical population ratios of the ground fine-structure levels of some atoms/ions which typically exhibit UV lines in the spectra of QSO absorbers redward the Ly-alpha forest: C0, C+, O0, Si+ and Fe+. The most reliable atomic data available is employed and a variety of excitation mechanisms considered: collisions with several particles in the medium, direct excitation by photons…
▽ More
We calculate theoretical population ratios of the ground fine-structure levels of some atoms/ions which typically exhibit UV lines in the spectra of QSO absorbers redward the Ly-alpha forest: C0, C+, O0, Si+ and Fe+. The most reliable atomic data available is employed and a variety of excitation mechanisms considered: collisions with several particles in the medium, direct excitation by photons from the cosmic microwave background radiation (CMBR) and fluorescence induced by a UV field present.
The theoretical population ratios are confronted with the corresponding column density ratios of C I and C II lines observed in damped Ly-alpha (DLA) and Lyman Limit (LL) systems collected in the recent literature to infer their physical conditions.
The volumetric density of neutral hydrogen in DLA systems is constrained to be lower than tens of cm^-3 (or a few cm^-3 in the best cases) and the UV radiation field intensity must be lower than two orders of magnitude the radiation field of the Galaxy (one order of magnitude in the best cases). Their characteristic sizes are higher than a few pc (tens of pc in the best cases) and lower limits for their total masses vary from 10^0 to 10^5 solar masses.
For the only LL system in our sample, the electronic density is constrained to be n_e<0.15 cm^-3. We suggest that the fine-structure lines may be used to discriminate between the current accepted picture of the UV extragalatic background as the source of ionization in these systems against a local origin for the ionizing radiation as supported by some authors.
We also investigate the validity of the temperature-redshift relation of the CMBR predicted by the standard model and study the case for alternative models.
△ Less
Submitted 14 December, 2000;
originally announced December 2000.
-
PopRatio: A program to calculate atomic level populations in astrophysical plasmas
Authors:
A. I. Silva,
S. M. Viegas
Abstract:
We describe a Fortran 90 program to calculate population ratios of atomic levels. The program solves the equations of statistical equilibrium considering all possible bound-bound processes: spontaneous, collisional or radiation induced (the later either directly or by fluorescence). There is no limit on the number of levels or in the number of processes that may be taken into account. The progra…
▽ More
We describe a Fortran 90 program to calculate population ratios of atomic levels. The program solves the equations of statistical equilibrium considering all possible bound-bound processes: spontaneous, collisional or radiation induced (the later either directly or by fluorescence). There is no limit on the number of levels or in the number of processes that may be taken into account. The program may find a wide range of applicability in astronomical problems, such as interpreting fine-structure absorption lines or collisionally excited emission lines (such as coronal emission lines) in the spectra of several objects, and also in calculating the cooling rates due to collisional excitation.
△ Less
Submitted 25 October, 2000;
originally announced October 2000.