Characterization of a Diode Dosimeter for UHDR FLASH Radiotherapy
Authors:
Mahbubur Rahman,
Jakub Kozelka,
Jeff Hildreth,
Andreas Schonfeld,
Austin M. Sloop,
M. Ramish Ashraf,
Petr Bruza,
David J. Gladstone,
Brian W. Pogue,
William E. Simon,
Rongxiao Zhang
Abstract:
Purpose: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry.
Methods: Dose linearity, mean dose rate, and dose per pulse dependencies of the EDGE Detector were quantified and compared with dosimeters including a W1 scintillator detector, radiochromic film, and ioni…
▽ More
Purpose: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry.
Methods: Dose linearity, mean dose rate, and dose per pulse dependencies of the EDGE Detector were quantified and compared with dosimeters including a W1 scintillator detector, radiochromic film, and ionization chamber that were irradiated with a 10 MeV UHDR beam. The dose, dose rate and dose per pulse were controlled via an in-house developed scintillation-based feedback mechanism, repetition rate of the linear accelerator, and source-to-surface distance, respectively. Depth-dose profiles and temporal profiles at individual pulse resolution were compared to the film and scintillation measurements, respectively. The radiation-induced change in response sensitivity was quantified via irradiation of ~5kGy.
Results: The EDGE Detector agreed with film measurements in the measured range with varying dose (up to 70 Gy), dose rate (nearly 200 Gy/s), and dose per pulse (up to 0.63 Gy/pulse) on average to within 2%, 5%, and 1%, respectively. The detector also agreed with W1 scintillation detector on average to within 2% for dose per pulse (up to 0.78 Gy/pulse). The EDGE Detector signal was proportional to ion chamber (IC) measured dose, and mean dose rate in the bremsstrahlung tail to within 0.4% and 0.2% respectively. The EDGE Detector measured percent depth dose agreed with film to within 3% and per pulse output agreed with W1 scintillator to within -6% to +5%.
Conclusions: The EDGE Detector demonstrated dose linearity, mean dose rate independence, and dose per pulse independence for UHDR electron beams. It can quantify the beam spatially, and temporally at sub millisecond resolution.
△ Less
Submitted 8 May, 2023; v1 submitted 12 January, 2022;
originally announced January 2022.
A Knowledge graph representation of baseline characteristics for the Dutch proton therapy research registry
Authors:
Matthijs Sloep,
Petros Kalendralis,
Ananya Choudhury,
Lerau Seyben,
Jasper Snel,
Nibin Moni George,
Martijn Veening,
Johannes A. Langendijk,
Andre Dekker,
Johan van Soest,
Rianne Fijten
Abstract:
Cancer registries collect multisource data and provide valuable information that can lead to unique research opportunities. In the Netherlands, a registry and model-based approach (MBA) are used for the selection of patients that are eligible for proton therapy. We collected baseline characteristics including demographic, clinical, tumour and treatment information. These data were transformed into…
▽ More
Cancer registries collect multisource data and provide valuable information that can lead to unique research opportunities. In the Netherlands, a registry and model-based approach (MBA) are used for the selection of patients that are eligible for proton therapy. We collected baseline characteristics including demographic, clinical, tumour and treatment information. These data were transformed into a machine readable format using the FAIR (Findable, Accessible, Interoperable, Reusable) data principles and resulted in a knowledge graph with baseline characteristics of proton therapy patients. With this approach, we enable the possibility of linking external data sources and optimal flexibility to easily adapt the data structure of the existing knowledge graph to the needs of the clinic.
△ Less
Submitted 6 July, 2021;
originally announced July 2021.