-
Spectroscopic investigations on trivalent ruthenium ions in ruthenium perovskite oxide thin films
Authors:
S. Nakata,
R. Takahashi,
R. Matsumoto,
L. -F. Zhang,
H. Sumida,
S. Suzuki,
T. C. Fujita,
M. Kawasaki,
H. Wadati
Abstract:
The $d^5$ electron configurations under the crystal field, spin-orbit coupling, and Coulomb interaction give rise to a plethora of profound ground states. Ruthenium perovskite oxides exhibit a number of unconventional properties yet the Ru$^{4+}$ state ($4d^4$) is usually stable in these materials. In this regard, Ru$^{3+}$ ions in perovskite materials are expected to be a mesmerising playground o…
▽ More
The $d^5$ electron configurations under the crystal field, spin-orbit coupling, and Coulomb interaction give rise to a plethora of profound ground states. Ruthenium perovskite oxides exhibit a number of unconventional properties yet the Ru$^{4+}$ state ($4d^4$) is usually stable in these materials. In this regard, Ru$^{3+}$ ions in perovskite materials are expected to be a mesmerising playground of $4d^5$ electron configurations. Here, we report measurements of x-ray photoemission spectroscopy on recently synthesized perovskite ruthenium oxide thin films, LaRuO$_3$ and NdRuO$_3$, whose valence state of the ruthenium ions is trivalent. We discuss correlation and spin-orbit effects from the valence-band spectra, in particular an additional peak structure around 3-5 eV, reminiscent of the so-called 3 eV peak observed in Sr$_2$RuO$_4$. Moreover, we find that the core-level spectra of these materials are quantitatively different from those in other ruthenates which possess Ru$^{4+}$ ions, e.g., SrRuO$_3$. We therefore argue that the core level spectra of LaRuO$_3$ and NdRuO$_3$ are peculiar to the Ru$^{3+}$ states.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Performance evaluation of PSD for silicon ECAL
Authors:
Hiroaki Yamashiro,
Kiyotomo Kawagoe,
Taikan Suehara,
Tamaki Yoshioka,
Sudo Yuji,
Hiroki Sumida
Abstract:
We are developing position sensitive silicon detectors (PSD) which have an electrode at each of four corners so that the incident position of a charged particle can be obtained using signals from the electrodes. It is expected that the position resolution the electromagnetic calorimeter (ECAL) of the ILD detector will be improved by introducing PSD into the detection layers. In this study, we irra…
▽ More
We are developing position sensitive silicon detectors (PSD) which have an electrode at each of four corners so that the incident position of a charged particle can be obtained using signals from the electrodes. It is expected that the position resolution the electromagnetic calorimeter (ECAL) of the ILD detector will be improved by introducing PSD into the detection layers. In this study, we irradiated collimated laser beams to the surface of the PSD, varying the incident position. We found that the incident position can be well reconstructed from the signals if high resistance is implemented in the p+ layer. We also tried to observe the signal of particles by placing a radiative source on the PSD sensor.
△ Less
Submitted 23 March, 2017;
originally announced March 2017.
-
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Authors:
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
J. Apostolakis,
G. Folger,
C. Grefe,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
C. Carloganu,
V. Français,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
S. Cauwenbergh,
M. Tytgat,
A. Pingault,
N. Zaganidis,
E. Brianne,
A. Ebrahimi
, et al. (103 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, e…
▽ More
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
Optimization of layer composition for ILD ECAL
Authors:
Hiroki Sumida,
Masato Matama,
Yuji Sudo,
Taikan Suehara,
Tamaki Yoshioka,
Kiyotomo Kawagoe,
Daniel Jeans,
Tohru Takeshita,
Katsushige Kotera
Abstract:
International Large Detector (ILD) adopts Particle Flow Algorithm (PFA) for precise measurement of multiple jets. The electromagnetic calorimeter (ECAL) of ILD has two candidates sensor technologies for PFA, which are pixelized silicon sensors and scintillator-strips with silicon photomultipliers. Pixelized silicon sensors have higher granularity for PFA, however they have an issue of cost reducti…
▽ More
International Large Detector (ILD) adopts Particle Flow Algorithm (PFA) for precise measurement of multiple jets. The electromagnetic calorimeter (ECAL) of ILD has two candidates sensor technologies for PFA, which are pixelized silicon sensors and scintillator-strips with silicon photomultipliers. Pixelized silicon sensors have higher granularity for PFA, however they have an issue of cost reduction. In contrast, scintillator-strips have an advantage of relatively low cost and a disadvantage of degradation of position resolution by ghost hits, which are generated by orthogonal arrangement. Hybrid ECAL using both candidates is proposed to supplement these disadvantages. In this paper, we report an optimization study of the hybrid ECAL using detector simulation.
△ Less
Submitted 14 March, 2016;
originally announced March 2016.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
Characteristic study of silicon sensor for ILD ECAL
Authors:
Shusuke Takada,
Hiroto Hirai,
Kiyotomo Kawagoe,
Yohei Miyazaki,
Yuji Sudo,
Taikan Suehara,
Hiroki Sumida,
Tatsuhiko Tomita,
Hiraku Ueno,
Tamaki Yoshioka
Abstract:
Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence International Large Detector (ILD) needs high spatial resolution which can separate each particle in jets. We study pixelized silicon sensors as active material of I…
▽ More
Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence International Large Detector (ILD) needs high spatial resolution which can separate each particle in jets. We study pixelized silicon sensors as active material of ILD Silicon electro- magnetic calorimeter (SiECAL). This paper reports studies of temperature and humidity dependence on dark current and response of laser injection.
△ Less
Submitted 31 March, 2015;
originally announced March 2015.
-
Hybrid ECAL: Optimization and Related Developments
Authors:
T. Suehara,
H. Hirai,
H. Sumida,
H. Ueno,
Y. Sudo,
T. Yoshioka,
K. Kawagoe
Abstract:
Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high granularity and robust measurement of electromagnetic shower, and scintillator-tungsten ECAL, which gives affordable cost with similar performance to silicon. Opt…
▽ More
Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high granularity and robust measurement of electromagnetic shower, and scintillator-tungsten ECAL, which gives affordable cost with similar performance to silicon. Optimization and a data acquisition trial in a test bench for the hybrid ECAL are described in this article.
△ Less
Submitted 30 March, 2015;
originally announced March 2015.