-
Analysis of atomic-clock data to constrain variations of fundamental constants
Authors:
Nathaniel Sherrill,
Adam O. Parsons,
Charles F. A. Baynham,
William Bowden,
E. Anne Curtis,
Richard Hendricks,
Ian R. Hill,
Richard Hobson,
Helen S. Margolis,
Billy I. Robertson,
Marco Schioppo,
Krzysztof Szymaniec,
Alexandra Tofful,
Jacob Tunesi,
Rachel M. Godun,
Xavier Calmet
Abstract:
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio,…
▽ More
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio, $μ$. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
△ Less
Submitted 15 December, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Measuring the stability of fundamental constants with a network of clocks
Authors:
G. Barontini,
L. Blackburn,
V. Boyer,
F. Butuc-Mayer,
X. Calmet,
J. R. Crespo Lopez-Urrutia,
E. A. Curtis,
B. Darquie,
J. Dunningham,
N. J. Fitch,
E. M. Forgan,
K. Georgiou,
P. Gill,
R. M. Godun,
J. Goldwin,
V. Guarrera,
A. C. Harwood,
I. R. Hill,
R. J. Hendricks,
M. Jeong,
M. Y. H. Johnson,
M. Keller,
L. P. Kozhiparambil Sajith,
F. Kuipers,
H. S. Margolis
, et al. (19 additional authors not shown)
Abstract:
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the…
▽ More
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the goal of the recently launched QSNET project: A network of clocks for measuring the stability of fundamental constants. QSNET will include state-of-the-art atomic clocks, but will also develop next-generation molecular and highly charged ion clocks with enhanced sensitivity to variations of fundamental constants. We describe the technological and scientific aims of QSNET and evaluate its expected performance. We show that in the range of parameters probed by QSNET, either we will discover new physics, or we will impose new constraints on violations of fundamental symmetries and a range of theories beyond the Standard Model, including dark matter and dark energy models.
△ Less
Submitted 11 May, 2022; v1 submitted 20 December, 2021;
originally announced December 2021.
-
Frequency ratio of two optical clock transitions in $^{171}$Yb$^+$ and constraints on the time-variation of fundamental constants
Authors:
R. M. Godun,
P. B. R. Nisbet-Jones,
J. M. Jones,
S. A. King,
L. A. M. Johnson,
H. S. Margolis,
K. Szymaniec,
S. N. Lea,
K. Bongs,
P. Gill
Abstract:
Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171…
▽ More
Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of $6\times 10^{-16}$. Combining our results with those from other experiments, we report a three-fold improvement in the constraint on the time-variation of the proton-to-electron mass ratio, $\dotμ/μ = 0.2(1.1)\times 10^{-16}$ year$^{-1}$, along with an improved constraint on time-variation of the fine structure constant, $\dotα/α = -0.7(2.1)\times 10^{-17}$ year$^{-1}$.
△ Less
Submitted 1 October, 2014; v1 submitted 1 July, 2014;
originally announced July 2014.
-
Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts
Authors:
Ruoxin Li,
Kurt Gibble,
Krzysztof Szymaniec
Abstract:
We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase…
▽ More
We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase uncertainty to $1.1 \times 10^{-16}$. We derive the microwave lensing frequency shift for a cylindrical cavity with circular apertures. An analytic result with reasonable approximations is given, in addition to a full calculation that indicates a shift of $6.2 \times 10^{-17}$. The measurements and theoretical models we report, along with improved evaluations of collisional and microwave leakage induced frequency shifts, reduce the frequency uncertainty of the NPL-CsF2 standard to $2.3 \times 10^{-16}$, nearly a factor of two lower than its most recent complete evaluation.
△ Less
Submitted 12 July, 2011;
originally announced July 2011.
-
Cancellation of the collisional frequency shift in caesium fountain clocks
Authors:
K. Szymaniec,
W. Chalupczak,
E. Tiesinga,
C. J. Williams,
S. Weyers,
R. Wynands
Abstract:
We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F = 4, mF = 0> atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement…
▽ More
We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F = 4, mF = 0> atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in the performance of caesium fountain standards and a simplification in their operation. Our results also have implications for test operation of fountains at multiple pi/2 pulse areas.
△ Less
Submitted 12 December, 2006;
originally announced December 2006.