-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Technical Design Report for the LUXE Experiment
Authors:
H. Abramowicz,
M. Almanza Soto,
M. Altarelli,
R. Aßmann,
A. Athanassiadis,
G. Avoni,
T. Behnke,
M. Benettoni,
Y. Benhammou,
J. Bhatt,
T. Blackburn,
C. Blanch,
S. Bonaldo,
S. Boogert,
O. Borysov,
M. Borysova,
V. Boudry,
D. Breton,
R. Brinkmann,
M. Bruschi,
F. Burkart,
K. Büßer,
N. Cavanagh,
F. Dal Corso,
W. Decking
, et al. (109 additional authors not shown)
Abstract:
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger fiel…
▽ More
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger field and beyond. The further implications for the search of physics beyond the Standard Model are also discussed.
△ Less
Submitted 2 August, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter
Authors:
I. Laktineh,
B. Liu,
D. Boumediene,
Y. W. Baek,
D-W. Kim,
S. C. Lee,
B. G. Min,
S. W. Park,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh,
B. Liu,
B. Li,
N. Lumb
, et al. (53 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm $\times$ 1~cm pickup pads combined to a multi-threshold electronics. The prototype was exposed to hadron beams in both the CERN PS and the SPS beamlines in 2015 allowing the test of the SDHCAL in a large energy range from 3~GeV to 80~GeV. After introducing the method used to select the hadrons of our data and reject the muon and electron contamination, we present the energy reconstruction approach that we apply to the data collected from both beamlines and we discuss the response linearity and the energy resolution of the SDHCAL. The results obtained in the two beamlines confirm the excellent SDHCAL performance observed with the data collected with the same prototype in the SPS beamline in 2012. They also show the stability of the SDHCAL in different beam conditions and different time periods.
△ Less
Submitted 19 February, 2022;
originally announced February 2022.
-
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
Authors:
D. Boumediene,
A. Pingault,
M. Tytgat,
B. Bilki,
D. Northacker,
Y. Onel,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
R. Ete G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh
, et al. (65 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype
Authors:
CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
Y. Do,
A. Khan,
D. Kim,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
J. Apostolakis,
J. Giraud,
D. Grondin,
J. -Y. Hostachy,
O. Bach,
V. Bocharnikov,
E. Brianne
, et al. (81 additional authors not shown)
Abstract:
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorith…
▽ More
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.
△ Less
Submitted 18 September, 2019; v1 submitted 16 February, 2019;
originally announced February 2019.
-
Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC
Authors:
K. Kawagoe,
Y. Miura,
I. Sekiya,
T. Suehara,
T. Yoshioka,
S. Bilokin,
J. Bonis,
P. Cornebise,
A. Gallas,
A. Irles,
R. Pöschl,
F. Richard,
A. Thiebault,
D. Zerwas,
M. Anduze,
V. Balagura,
V. Boudry,
J-C. Brient,
E. Edy,
G. Fayolle,
M. Frotin,
F. Gastaldi,
R. Guillaumat,
A. Lobanov,
M. Louzir
, et al. (19 additional authors not shown)
Abstract:
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 $5.5\times5.5$ mm$^2$ silicon PIN diodes. The four sensors covered a total area of $18\times18$ cm$^2$, and comprise…
▽ More
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 $5.5\times5.5$ mm$^2$ silicon PIN diodes. The four sensors covered a total area of $18\times18$ cm$^2$, and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.
△ Less
Submitted 22 October, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.
-
Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models
Authors:
CALICE Collaboration,
M. Chefdeville,
J. Repond,
J. Schlereth,
J. R. Smith,
D. Trojand,
L. Xia,
Q. Zhang,
J. Apostolakis,
C. Grefe,
V. Ivantchenko,
G. Folger,
A. Ribon,
V. Uzhinskiy,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
V. Bocharnikov,
E. Brianne,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel
, et al. (71 additional authors not shown)
Abstract:
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of…
▽ More
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.
△ Less
Submitted 25 January, 2019;
originally announced January 2019.
-
Low power commissioning of an innovative laser beam circulator for inverse Compton scattering Gamma-ray source
Authors:
Cheikh Fall Ndiaye,
Kevin Cassou,
Patrick Cornebise,
Kevin Dupraz,
Denis Douillet,
Titouan Le Barillec,
Christopher Magueur,
Aurelien Martens,
Daniele Nutarelli,
Yann Peinaud,
Alice Thiebault,
Themis Williams,
Fabian Zomer,
Nicolas Beaugerard,
Bastien Lacrampe,
Hervé Rocipon,
David Alesini,
Fabio Cardelli,
Antonio Falone,
Giovanni Franzini,
Alessandro Gallo,
Luca Piersanti,
Valerio Petinacci,
Stefano Pioli,
Alessandro Variola
, et al. (2 additional authors not shown)
Abstract:
We report on the optical commissioning of the high power laser beam circulator (LBC) for the high brightness Compton γ-ray source Extreme Light Infrastructure for Nuclear Physics. Tests aiming at demonstrating the optical performances of the LBC have been realized with a low-power pulsed laser-beam system and without electron beam. We show that, with the developed alignment and synchronization met…
▽ More
We report on the optical commissioning of the high power laser beam circulator (LBC) for the high brightness Compton γ-ray source Extreme Light Infrastructure for Nuclear Physics. Tests aiming at demonstrating the optical performances of the LBC have been realized with a low-power pulsed laser-beam system and without electron beam. We show that, with the developed alignment and synchronization methods coming from the LBC design study presented in the Dupraz et al. paper [1], the LBC enhances the laser-beam power available at the interaction point (IP) by a factor in excess of 25. This corresponds to a potential of bringing the average laser-beam power in excess of 1 kW when the LBC is injected with the interaction point laser-beam pulse energy of 400 mJ at 100 Hz.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.
-
Commissioning of the highly granular SiW-ECAL technological prototype
Authors:
S. Bilokin,
J. Bonis,
P. Cornebise,
A. Gallas,
A. Irles,
R. Pöschl,
F. Richard,
A. Thiebault,
D. Zerwas,
M. Anduze,
V. Balagura,
V. Boudry,
J-C. Brient,
E. Edy,
G. Fayolle,
M. Frotin,
F. Gastaldi,
A. Lobanov,
F. Magniette,
J. Nanni,
M. Rubio-Roy,
K. Shpak,
H. Videau,
D. Yu,
S. Callier
, et al. (18 additional authors not shown)
Abstract:
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record si…
▽ More
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record signals as low as 0.5 MIP. Further, no loss of performance has been observed when operating the detector in a high magnetic field.
△ Less
Submitted 4 April, 2019; v1 submitted 11 October, 2018;
originally announced October 2018.
-
Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System
Authors:
CALICE Collaboration,
J. Repond,
L. Xia,
J. Apostolakis,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
V. Francais,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Gttlicher,
O. Hartbrich F. Krivan,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza
, et al. (84 additional authors not shown)
Abstract:
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles.…
▽ More
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
△ Less
Submitted 12 September, 2018; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
Authors:
CALICE collaboration,
J. Repond,
L. Xia,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
M. A. Thomson,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
F. Krivan,
K. Krüger,
S. Lu,
B. Lutz,
M. Reinecke,
F. Sefkow,
Y. Sudo,
H. L. Tran,
A. Kaplan,
H. -Ch. Schultz-Coulon
, et al. (57 additional authors not shown)
Abstract:
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab…
▽ More
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.
△ Less
Submitted 28 February, 2018; v1 submitted 22 July, 2017;
originally announced July 2017.
-
SiW ECAL for future $e^+e^-$ collider
Authors:
V. Balagura,
S. Bilokin,
J. Bonis,
V. Boudry,
J. -C. Brient,
S. Callier,
T. Cheng,
R. Cornat,
C. De La Taille,
T. H. Doan,
M. Frotin,
F. Gastaldi,
H. Hirai,
S. Jain,
Sh. Jain,
D. Lacour,
L. Lavergne,
A. Lleres,
F. Magniette,
L. Mastrolorenzo,
J. Nanni,
R. Poeschl,
A. Pozdnyakov,
A. Psallidas,
M. Ruan
, et al. (7 additional authors not shown)
Abstract:
Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We discuss the tests of the first three 18x18 cm$^2$ layers segmented into 1024 pixels of the technological prototype of the silicon-tungsten electromagnetic calorimeter for a future $e^+e^-$ collider. The tests have beem performed in November 2015 at CERN SPS beam line.
Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We discuss the tests of the first three 18x18 cm$^2$ layers segmented into 1024 pixels of the technological prototype of the silicon-tungsten electromagnetic calorimeter for a future $e^+e^-$ collider. The tests have beem performed in November 2015 at CERN SPS beam line.
△ Less
Submitted 20 June, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Authors:
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
J. Apostolakis,
G. Folger,
C. Grefe,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
C. Carloganu,
V. Français,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
S. Cauwenbergh,
M. Tytgat,
A. Pingault,
N. Zaganidis,
E. Brianne,
A. Ebrahimi
, et al. (103 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, e…
▽ More
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
DHCAL with Minimal Absorber: Measurements with Positrons
Authors:
The CALICE Collaboration,
B. Freund,
C. Neubüser,
J. Repond,
J. Schlereth,
L. Xia,
A. Dotti,
C. Grefe,
V. Ivantchenko,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg,
A. Irles,
F. Krivan,
K. Krüger
, et al. (78 additional authors not shown)
Abstract:
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on…
▽ More
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.