Identification of organic molecules with a laboratory prototype based on the Laser Ablation-CosmOrbitrap
Authors:
L. Selliez,
C. Briois,
N. Carrasco,
L. Thirkell,
R. Thissen,
M. Ito,
F. -R. Orthous-Daunay,
G. Chalumeau,
F. Colin,
H. Cottin,
C. Engrand,
L. Flandinet,
N. Fray,
B. Gaubicher,
N. Grand,
J. -P. Lebreton,
A. Makarov,
S. Ruocco,
C. Szopa,
V. Vuitton,
P. Zapf
Abstract:
In the Solar System, extra-terrestrial organic molecules have been found on cometary primitive objects, on Titan and Enceladus icy moons and on Mars. Identification could be achieved for simple organic species by remote sensing based on spectroscopic methods. However in situ mass spectrometry is a key technology to determine the nature of more complex organic matter. A new concept of mass analyser…
▽ More
In the Solar System, extra-terrestrial organic molecules have been found on cometary primitive objects, on Titan and Enceladus icy moons and on Mars. Identification could be achieved for simple organic species by remote sensing based on spectroscopic methods. However in situ mass spectrometry is a key technology to determine the nature of more complex organic matter. A new concept of mass analyser offering ultra-high mass resolving power of more than 50,000 at m/z 56 (under high vacuum condition about 10-9 mbar) is currently being developed for space applications: the CosmOrbitrap (Briois et al., 2016), based on the OrbitrapTM technology. This work challenges the use of LAb-CosmOrbitrap, a space instrument prototype combining Laser Ablation ionisation and the CosmOrbitrap mass analyser, to identify solid organic molecules of relevance to the future space exploration. For this purpose a blind test was jointly organised by the JAXA-HRMS team (Japan Aerospace Exploration Agency-High Resolution Mass Spectrometry) and the CosmOrbitrap consortium. The JAXA team provided two organic samples, whereas the CosmOrbitrap consortium analysed them without prior information. Thanks to the high analytical performances of the prototype and our HRMS data post-processing, we successfully identified the two molecules as HOBt, hydroxybenzotriazole (C6H5N3O) and BBOT, 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene (C26H26N2O2S), with a mass resolving power of, respectively, 123 540 and 69 219. The success of this blind test on complex organic molecules shows the strong potential of LAb-CosmOrbitrap for future space applications.
△ Less
Submitted 20 April, 2019;
originally announced April 2019.
-
An Orbitrap-based laser desorption/ablation mass spectrometer designed for spaceflight
Authors:
Ricardo Arevalo Jr.,
Laura Selliez,
Christelle Briois,
Nathalie Carrasco,
Laurent Thirkell,
Barnabé Cherville,
Fabrice Colin,
Bertrand Gaubicher,
Benjamin Farcy,
Xiang Li,
Alexander Makarov
Abstract:
RATIONALE: The investigation of cryogenic planetary environments as potential harbors for extant life and/or contemporary sites of organic synthesis represents an emerging focal point in planetary exploration. Next generation instruments need to be capable of unambiguously determining elemental and/or molecular stoichiometry via highly accurate mass measurements and the separation of isobaric inte…
▽ More
RATIONALE: The investigation of cryogenic planetary environments as potential harbors for extant life and/or contemporary sites of organic synthesis represents an emerging focal point in planetary exploration. Next generation instruments need to be capable of unambiguously determining elemental and/or molecular stoichiometry via highly accurate mass measurements and the separation of isobaric interferences. METHODS: An OrbitrapTM analyzer adapted for spaceflight (referred to as the CosmOrbitrap), coupled with a commercial pulsed UV laser source (266 nm), is shown to successfully characterize a variety of planetary analog samples via ultrahigh resolution laser desorption/ablation mass spectrometry. The materials analyzed in this study include: jarosite (a hydrous sulfate detected on Mars); magnesium sulfate (a potential component of the subsurface ocean on Europa); uracil (a nucleobase of RNA); and a variety of amino acids. RESULTS: The instrument configuration tested here enables: measurement of major elements and organic molecules with ultrahigh mass resolution (m/Δm higher than 120,000, FWHM); quantification of isotopic abundances with 1.0% (2σ) precision; and, identification of highly accurate masses within 3.2 ppm of absolute values. The analysis of a residue of a dilute solution of amino acids demonstrates the capacity to detect twelve amino acids in positive ion mode at concentrations as low as 1 pmol/mm2 while maintaining mass resolution and accuracy requirements. CONCLUSIONS: The CosmOrbitrap mass analyzer is highly sensitive and delivers mass resolution/accuracy unmatched by any instrument sent into orbit or launched into deep space. This prototype instrument, which maps to a spaceflight implementation, represents a missionenabling technology capable of advancing planetary exploration for decades to come.
△ Less
Submitted 25 July, 2018;
originally announced July 2018.
-
COSIMA-Rosetta calibration for in-situ characterization of 67P/Churyumov-Gerasimenko cometary inorganic compounds
Authors:
Harald Krüger,
Thomas Stephan,
Cécile Engrand,
Christelle Briois,
Sandra Siljeström,
Sihane Merouane,
Donia Baklouti,
Henning Fischer,
Nicolas Fray,
Klaus Hornung,
Harry Lehto,
François-Régis Orthous-Daunay,
Jouni Rynö,
Rita Schulz,
Johan Silen,
Laurent Thirkell,
Mario Trieloff,
Martin Hilchenbach
Abstract:
COSIMA (COmetary Secondary Ion Mass Analyser) is a time-of-flight secondary ion mass spectrometer (TOF-SIMS) on board the Rosetta space mission. COSIMA has been designed to measure the composition of cometary dust grains. It has a mass resolution m/Δm of 1400 at mass 100 u, thus enabling the discrimination of inorganic mass peaks from organic ones in the mass spectra. We have evaluated the identif…
▽ More
COSIMA (COmetary Secondary Ion Mass Analyser) is a time-of-flight secondary ion mass spectrometer (TOF-SIMS) on board the Rosetta space mission. COSIMA has been designed to measure the composition of cometary dust grains. It has a mass resolution m/Δm of 1400 at mass 100 u, thus enabling the discrimination of inorganic mass peaks from organic ones in the mass spectra. We have evaluated the identification capabilities of the reference model of COSIMA for inorganic compounds using a suite of terrestrial minerals that are relevant for cometary science. Ground calibration demonstrated that the performances of the flight model were similar to that of the reference model. The list of minerals used in this study was chosen based on the mineralogy of meteorites, interplanetary dust particles and Stardust samples. It contains anhydrous and hydrous ferromagnesian silicates, refractory silicates and oxides (present in meteoritic Ca-Al-rich inclusions), carbonates, and Fe-Ni sulfides. From the analyses of these minerals, we have calculated relative sensitivity factors for a suite of major and minor elements in order to provide a basis for element quantification for the possible identification of major mineral classes present in the cometary grains.
△ Less
Submitted 4 January, 2015;
originally announced January 2015.