-
A silicon source of heralded single photons at 2 $μ$m
Authors:
S. Signorini,
M. Sanna,
S. Piccione,
M. Ghulinyan,
P. Tidemand-Lichtenberg,
C. Pedersen,
L. Pavesi
Abstract:
Mid infrared integrated quantum photonics is a promising platform for applications in sensing and metrology. However, there are only few examples of on-chip single photon sources at these wavelengths. These have limited performances with respect to their C-band counterparts. In this work, we demonstrate a new approach to generate heralded single photons in the mid infrared on a silicon chip. By us…
▽ More
Mid infrared integrated quantum photonics is a promising platform for applications in sensing and metrology. However, there are only few examples of on-chip single photon sources at these wavelengths. These have limited performances with respect to their C-band counterparts. In this work, we demonstrate a new approach to generate heralded single photons in the mid infrared on a silicon chip. By using a standard C-band pump, the inter-modal spontaneous four wave mixing enables the generation of the herald idler at 1259.7 nm and the heralded signal at 2015 nm. The idler photon is easily detected with a common infrared single photon detector while the signal photon is upconverted to the visible before its detection. In this way, we are able to operate a mid infrared source without the need of mid infrared detectors and laser sources. By measuring a heralded $g^{(2)}$ of $0.23 \, \pm \, 0.08$ we demonstrate the single photon behaviour of the source as well as the feasibility of multi-photon coincidence measurements beyond 2 $μ$m with our setup. The source exhibits a high intrinsic heralding efficiency of $(59 \, \pm \,5)\%$, a maximum coincidence to accidental ratio of $40.4 \, \pm \, 0.9$ and a generation probability of $\left( 0.72 \, \pm \, 0.10 \right)$ W$^{-2}$.
△ Less
Submitted 2 August, 2021;
originally announced August 2021.
-
High resolution mid-infrared optical coherence tomography with kHz line rate
Authors:
Niels M. Israelsen,
Peter John Rodrigo,
Christian R. Petersen,
Getinet Woyessa,
Rasmus E. Hansen,
Peter Tidemand-Lichtenberg,
Christian Pedersen,
Ole Bang
Abstract:
We report on Mid-infrared (MIR) OCT at 4 $μ$m based on collinear sum-frequency upconversion and promote the A-scan scan rate to 3 kHz. We demonstrate the increased imaging speed for two spectral realizations, one providing an axial resolution of 8.6 $μ$m, and one providing a record axial resolution of 5.8 $μ$m. Image performance is evaluated by sub-surface micro-mapping of a plastic glove and real…
▽ More
We report on Mid-infrared (MIR) OCT at 4 $μ$m based on collinear sum-frequency upconversion and promote the A-scan scan rate to 3 kHz. We demonstrate the increased imaging speed for two spectral realizations, one providing an axial resolution of 8.6 $μ$m, and one providing a record axial resolution of 5.8 $μ$m. Image performance is evaluated by sub-surface micro-mapping of a plastic glove and real-time monitoring of CO$_2$ in parallel with OCT imaging.
△ Less
Submitted 31 May, 2021;
originally announced June 2021.
-
Real-time High-Resolution Mid-infrared Optical Coherence Tomography
Authors:
Niels M. Israelsen,
Christian R. Petersen,
Ajanta Barh,
Deepak Jain,
Mikkel Jensen,
Günther Hannesschläger,
Peter Tidemand-Lichtenberg,
Christian Pedersen,
Adrian Podoleanu,
Ole Bang
Abstract:
The potential for improving the penetration depth of optical coherence tomography systems by using increasingly longer wavelength light sources has been known since the inception of the technique in the early 1990s. Nevertheless, the development of mid-infrared optical coherence tomography has long been challenged by the maturity and fidelity of optical components in this spectral region, resultin…
▽ More
The potential for improving the penetration depth of optical coherence tomography systems by using increasingly longer wavelength light sources has been known since the inception of the technique in the early 1990s. Nevertheless, the development of mid-infrared optical coherence tomography has long been challenged by the maturity and fidelity of optical components in this spectral region, resulting in slow acquisition, low sensitivity, and poor axial resolution. In this work, a mid-infrared spectral-domain optical coherence tomography system operating at 4 micron central wavelength with an axial resolution of 8.6 microns is demonstrated. The system produces 2D cross-sectional images in real-time enabled by a high-brightness 0.9-4.7 micron mid-infrared supercontinuum source with 1 MHz pulse repetition rate for illumination and broadband upconversion of more than 1 micron bandwidth from 3.58-4.63 microns to 820-865 nm, where a standard 800 nm spectrometer can be used for fast detection. Images produced by the mid-infrared system are compared with those delivered by a state-of-the-art ultra-high-resolution near-infrared optical coherence tomography system operating at 1.3 μm, and the potential applications and samples suited for this technology are discussed. In doing so, the first practical mid-infrared optical coherence tomography system is demonstrated, with immediate applications in real-time non-destructive testing for the inspection of defects and thickness measurements in samples that are too highly scattering at shorter wavelengths.
△ Less
Submitted 14 March, 2019; v1 submitted 12 October, 2018;
originally announced October 2018.
-
Room temperature mid-IR single photon spectral imaging
Authors:
Jeppe Seidelin Dam,
Christian Pedersen,
Peter Tidemand-Lichtenberg
Abstract:
Spectral imaging and detection of mid-infrared (mid-IR) wavelengths are emerging as an enabling technology of great technical and scientific interest; primarily because important chemical compounds display unique and strong mid-IR spectral fingerprints revealing valuable chemical information. While modern Quantum cascade lasers have evolved as ideal coherent mid-IR excitation sources, simple, low…
▽ More
Spectral imaging and detection of mid-infrared (mid-IR) wavelengths are emerging as an enabling technology of great technical and scientific interest; primarily because important chemical compounds display unique and strong mid-IR spectral fingerprints revealing valuable chemical information. While modern Quantum cascade lasers have evolved as ideal coherent mid-IR excitation sources, simple, low noise, room temperature detectors and imaging systems still lag behind. We address this need presenting a novel, field-deployable, upconversion system for sensitive, 2-D, mid-IR spectral imaging. Measured room temperature dark noise is 0.2 photons/spatial element/second, which is a billion times below the dark noise level of cryogenically cooled InSb cameras. Single photon imaging and up to 200 x 100 spatial elements resolution is obtained reaching record high continuous wave quantum efficiency of about 20 % for polarized incoherent light at 3 \mum. The proposed method is relevant for existing and new mid-IR applications like gas analysis and medical diagnostics.
△ Less
Submitted 7 August, 2012;
originally announced August 2012.
-
Squeezing based on nondegenerate frequency doubling internal to a realistic laser
Authors:
Ulrik L. Andersen,
Peter Tidemand-Lichtenberg,
Preben Buchhave
Abstract:
We investigate theoretically the quantum fluctuations of the fundamental field in the output of a nondegenerate second harmonic generation process occuring inside a laser cavity. Due to the nondegenerate character of the nonlinear medium, a field orthogonal to the laser field is for some operating conditions indepedent of the fluctuations produced by the laser medium. We show that this fact may…
▽ More
We investigate theoretically the quantum fluctuations of the fundamental field in the output of a nondegenerate second harmonic generation process occuring inside a laser cavity. Due to the nondegenerate character of the nonlinear medium, a field orthogonal to the laser field is for some operating conditions indepedent of the fluctuations produced by the laser medium. We show that this fact may lead to perfect squeezing for a certain polarization mode of the fundamental field. The experimental feasibility of the system is also discussed.
△ Less
Submitted 6 June, 2003;
originally announced June 2003.