-
Epidemiology of Objectively Measured Bedtime and Chronotype in the US adolescents and adults: NHANES 2003-2006
Authors:
Jacek K. Urbanek,
Adam Spira,
Junrui Di,
Andrew Leroux,
Ciprian Crainiceanu,
Vadim Zipunnikov
Abstract:
Background: We propose a method for estimating the timing of in-bed intervals using objective data in a large representative U.S. sample, and quantify the association between these intervals and age, sex, and day of the week. Methods: The study included 11,951 participants six years and older from the National Health and Nutrition Examination Survey (NHANES) 2003-2006, who wore accelerometers to m…
▽ More
Background: We propose a method for estimating the timing of in-bed intervals using objective data in a large representative U.S. sample, and quantify the association between these intervals and age, sex, and day of the week. Methods: The study included 11,951 participants six years and older from the National Health and Nutrition Examination Survey (NHANES) 2003-2006, who wore accelerometers to measure physical activity for seven consecutive days. Participants were instructed to remove the device just before the nighttime sleep period and put it back on immediately after. This nighttime period of non-wear was defined in this paper as the objective bedtime (OBT), an objectively estimated record of the in-bed-interval. For each night of the week, we estimated two measures: the duration of the OBT (OBT-D) and, as a measure of the chronotype, the midpoint of the OBT (OBT-M). We estimated day-of-the-week-specific OBT-D and OBT-M using gender-specific population percentile curves. Differences in OBT-M (chronotype) and OBT-D (the amount of time spent in bed) by age and sex were estimated using regression models. Results: The estimates of OBT-M and their differences among age groups were consistent with the estimates of chronotype obtained via self-report in European populations. The average OBT-M varied significantly by age, while OBT-D was less variable with age. The most pronounced differences were observed between OBT-M of weekday and weekend nights. Conclusions: The proposed measures, OBT-D and OBT-M, provide useful information of time in bed and chronotype in NHANES 2003-2006. They identify within-week patterns of bedtime and can be used to study associations between the bedtime and the large number of health outcomes collected in NHANES 2003-2006.
△ Less
Submitted 16 June, 2017;
originally announced June 2017.
-
Validation of gait characteristics extracted from raw accelerometry during walking against measures of physical function, mobility, fatigability, and fitness
Authors:
Jacek K. Urbanek,
Vadim Zipunnikov,
Tamara Harris,
Ciprian Crainiceanu,
Jaroslaw Harezlak,
Nancy W. Glynn
Abstract:
Background. Wearable accelerometry devices allow collection of high-density activity data in large epidemiological studies both in-the-lab as well as in-the-wild (free-living). Such data can be used to detect and identify periods of sustained harmonic walking. This report aims to establish whether the micro- and macro-features of walking identified in the laboratory and free-living environments ar…
▽ More
Background. Wearable accelerometry devices allow collection of high-density activity data in large epidemiological studies both in-the-lab as well as in-the-wild (free-living). Such data can be used to detect and identify periods of sustained harmonic walking. This report aims to establish whether the micro- and macro-features of walking identified in the laboratory and free-living environments are associated with measures of physical function, mobility, fatigability, and fitness.
Methods. Fifty-one older adults (median age 77.5) enrolled in the Developmental Epidemiologic Cohort Study in Pittsburgh, Pennsylvania were included in the analyses. The study included an in-the-lab component as well as 7 days of monitoring in-the-wild. Participants were equipped with hip-worn Actigraph GT3X+ activity monitors, which collect high-density raw accelerometry data. We applied a walking identification algorithm to the data and defined features of walking, such as participant-specific walking acceleration and cadence. The association between these walking features and physical function, mobility, fatigability, and fitness was quantified using linear regression analysis.
Results. Micro-scale features of walking (acceleration and cadence) estimated from in-the-lab and in-the-wild data were associated with measures of physical function, mobility, fatigability, and fitness. In-the-lab median walking acceleration was strongly inversely associated with physical function, mobility, fatigability and fitness. Additionally, in-the-wild daily walking time was inversely associated with usual- and fast-paced 400m walking time.
Conclusions. The proposed accelerometry-derived walking features are significantly associated with measures of physical function, mobility, fatigability, and fitness, which provides evidence of convergent validity.
△ Less
Submitted 16 November, 2017; v1 submitted 15 December, 2016;
originally announced December 2016.
-
Stride variability measures derived from wrist- and hip-worn accelerometers
Authors:
Jacek K. Urbanek,
Jaroslaw Harezlak,
Nancy W. Glynn,
Tamara Harris,
Ciprian Crainiceanu,
Vadim Zipunnikov
Abstract:
Many epidemiological and clinical studies use accelerometry to objectively measure physical activity using the activity counts, vector magnitude, or number of steps. These measures use just a fraction of the information in the raw accelerometry data as they are typically summarized at the minute level. To address this problem we define and estimate two gait measures of temporal stride-to-stride va…
▽ More
Many epidemiological and clinical studies use accelerometry to objectively measure physical activity using the activity counts, vector magnitude, or number of steps. These measures use just a fraction of the information in the raw accelerometry data as they are typically summarized at the minute level. To address this problem we define and estimate two gait measures of temporal stride-to-stride variability based on raw accelerometry data: Amplitude Deviation (AD) and Phase Deviation (PD). We explore the sensitivity of our approach to on-body placement of the accelerometer by comparing hip, left and right wrist placements. We illustrate the approach by estimating AD and PD in 46 elderly participants in the Developmental Epidemiologic Cohort Study (DECOS) who worn accelerometers during a 400 meter walk test. We also show that AD and PD have a statistically significant association with the gait speed and sit-to-stand test performance
△ Less
Submitted 30 June, 2016;
originally announced June 2016.
-
Prediction of sustained harmonic walking in the free-living environment using raw accelerometry data
Authors:
Jacek K. Urbanek,
Vadim Zipunnikov,
Tamara Harris,
William Fadel,
Nancy Glynn,
Annemarie Koster,
Paolo Caserotti,
Ciprian Crainiceanu,
Jaroslaw Harezlak
Abstract:
Objective. Using raw, sub-second level, accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on the sustained harmonic walking (SHW), which we define as walking for at least 10 seconds with low variability of step frequency. Approach. We utilize the harmonic nature of SHW and quantify local periodicity of the tri-a…
▽ More
Objective. Using raw, sub-second level, accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on the sustained harmonic walking (SHW), which we define as walking for at least 10 seconds with low variability of step frequency. Approach. We utilize the harmonic nature of SHW and quantify local periodicity of the tri-axial raw accelerometry data. We also estimate fundamental frequency of observed signals and link it to the instantaneous walking (step-to-step) frequency (IWF). Next, we report total time spent in SHW, number and durations of SHW bouts, time of the day when SHW occurred and IWF for 49 healthy, elderly individuals. Main results. Sensitivity of the proposed classification method was found to be 97%, while specificity ranged between 87% and 97% and prediction accuracy between 94% and 97%. We report total time in SHW between 140 and 10 minutes-per-day distributed between 340 and 50 bouts. We estimate the average IWF to be 1.7 steps-per-second. Significance. We propose a simple approach for detection of SHW and estimation of IWF, based on Fourier decomposition. The resulting approach is fast and allows processing of a week-long raw accelerometry data (approx. 150 million measurements) in relatively short time (~half an hour) on a common laptop computer (2.8 GHz Intel Core i7, 16 GB DDR3 RAM).
△ Less
Submitted 16 November, 2017; v1 submitted 15 May, 2015;
originally announced May 2015.