Ultrafast 1 MHz vacuum-ultraviolet source via highly cascaded harmonic generation in negative-curvature hollow-core fibers
Authors:
David E. Couch,
Daniel D. Hickstein,
David G. Winters,
Sterling J. Backus,
Matthew S. Kirchner,
Scott R. Domingue,
Jessica J. Ramirez,
Charles G. Durfee,
Margaret M. Murnane,
Henry C. Kapteyn
Abstract:
Vacuum ultraviolet (VUV) light is critical for the study of molecules and materials, but the generation of femtosecond pulses in the VUV region at high repetition rates has proven difficult. Here, we demonstrate the efficient generation of VUV light at MHz repetition rates using highly cascaded four-wave mixing processes in a negative-curvature hollow-core fiber. Both even and odd order harmonics…
▽ More
Vacuum ultraviolet (VUV) light is critical for the study of molecules and materials, but the generation of femtosecond pulses in the VUV region at high repetition rates has proven difficult. Here, we demonstrate the efficient generation of VUV light at MHz repetition rates using highly cascaded four-wave mixing processes in a negative-curvature hollow-core fiber. Both even and odd order harmonics are generated up to the 15th harmonic (69 nm, 18.0 eV), with high energy resolution of ~40 meV. In contrast to direct high harmonic generation, this highly cascaded harmonic generation process requires lower peak intensity and therefore can operate at higher repetition rates, driven by a robust ~10 W fiber-laser system in a compact setup. Additionally, we present numerical simulations that explore the fundamental capabilities and spatiotemporal dynamics of highly cascaded harmonic generation. This VUV source can enhance the capabilities of spectroscopies of molecular and quantum materials, such as photoionization mass spectrometry and time , angle , and spin-resolved photoemission.
△ Less
Submitted 7 July, 2020; v1 submitted 28 April, 2020;
originally announced April 2020.
-
Ultrasensitive Doppler Raman spectroscopy using radio frequency phase shift detection
Authors:
David R. Smith,
Jeffrey J. Field,
David G. Winters,
Scott Domingue,
Frauke Rininsland,
Daniel J. Kane,
Jesse W. Wilson,
Randy A. Bartels
Abstract:
We introduce the first method to enable an optical amplification of a coherent Raman spectroscopy signal called radio frequency Doppler Raman spectroscopy. Doppler Raman measurements amplify the optical signals in coherent Raman spectroscopy by converting a spectral frequency shift imparted by an impulsive coherent Raman excitation to a change in a probe pulse transit time. This transit time pertu…
▽ More
We introduce the first method to enable an optical amplification of a coherent Raman spectroscopy signal called radio frequency Doppler Raman spectroscopy. Doppler Raman measurements amplify the optical signals in coherent Raman spectroscopy by converting a spectral frequency shift imparted by an impulsive coherent Raman excitation to a change in a probe pulse transit time. This transit time perturbation is detected through the phase of a radio frequency electronic signal measured at a harmonic of the probe pulse train. By exploiting this new capability to scale the signal of a coherent Raman spectroscopic signal, we open the potential to detect very weak Raman spectroscopy signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen.
△ Less
Submitted 9 December, 2019;
originally announced December 2019.
-
A plane wave analysis of coherent holographic image reconstruction by phase transfer
Authors:
Jeffrey J. Field,
David G. Winters,
Randy A. Bartels
Abstract:
Fluorescent imaging plays a critical role in a myriad of scientific endeavors, particularly in the biological sciences. Three-dimensional imaging of fluorescent intensity often requires serial data acquisition, that is voxel-by-voxel collection of fluorescent light emitted throughout the specimen with a non-imaging single-element detector. While non-imaging fluorescence detection offers some measu…
▽ More
Fluorescent imaging plays a critical role in a myriad of scientific endeavors, particularly in the biological sciences. Three-dimensional imaging of fluorescent intensity often requires serial data acquisition, that is voxel-by-voxel collection of fluorescent light emitted throughout the specimen with a non-imaging single-element detector. While non-imaging fluorescence detection offers some measure of scattering robustness, the rate at which dynamic specimens can be imaged is severely limited. Other fluorescent imaging techniques utilize imaging detection to enhance collection rates. A notable example is light-sheet fluorescence microscopy, also known as selective-plane illumination microscopy (SPIM), which illuminates a large region within the specimen and collects emitted fluorescent light at an angle either perpendicular or oblique to the illumination light sheet. Unfortunately, scattering of the emitted fluorescent light can cause blurring of the collected images in highly turbid biological media. We recently introduced an imaging technique called coherent holographic image reconstruction by phase transfer (CHIRPT) that combines light-sheet-like illumination with non-imaging fluorescent light detection. By combining the speed of light-sheet illumination with the scattering robustness of non-imaging detection, CHIRPT is poised to have a dramatic impact on biological imaging, particularly for $\textit{in vivo}$ preparations. Here we present the mathematical formalism for CHIRPT imaging under spatially coherent illumination and present experimental data that verifies the theoretical model.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Phase-sensitive fluorescent imaging with coherent reconstruction
Authors:
Jeffrey J. Field,
David G. Winters,
Randy A. Bartels
Abstract:
Optical imaging plays a critical role in advancing our understanding of three dimensional dynamics of biological systems. Coherent imaging (CI) methods exploit spatial phase information, encoded through propagation of coherent signal light emerging from a specimen, to extract a three-dimensional representation of the object from a single high-speed measurement. Until now, CI methods could not be a…
▽ More
Optical imaging plays a critical role in advancing our understanding of three dimensional dynamics of biological systems. Coherent imaging (CI) methods exploit spatial phase information, encoded through propagation of coherent signal light emerging from a specimen, to extract a three-dimensional representation of the object from a single high-speed measurement. Until now, CI methods could not be applied to incoherent light, severely limiting their ability to image the most powerful biological probes available - fluorescent molecules - with sufficient speed and volume to observe important processes, such as neural processing in live specimens. We introduce a new imaging technique that transfers the spatial propagation phase of coherent illumination light to incoherent fluorescent light emission. The transfer of propagation phase allows CI techniques to be applied to fluorescent light imaging, and leads to large increases in imaging speed and depth of field. With this advance, biological imaging of fluorescent molecules is significantly expanded.
△ Less
Submitted 22 July, 2015;
originally announced July 2015.