Design, Construction, and Test of Compact, Distributed-Charge, X-Band Accelerator Systems that Enable Image-Guided, VHEE FLASH Radiotherapy
Authors:
Christopher P. J. Barty,
J. Martin Algots,
Alexander J. Amador,
James C. R. Barty,
Shawn M. Betts,
Marcelo A. Casteñada,
Matthew M. Chu,
Michael E. Daley,
Ricardo A. De Luna Lopez,
Derek A. Diviak,
Haytham H. Effarah,
Roberto Feliciano,
Adan Garcia,
Keith J. Grabiel,
Alex S. Griffin,
Frederic V. Hartemann,
Leslie Heid,
Yoonwoo Hwang,
Gennady Imeshev,
Michael Jentschel,
Christopher A. Johnson,
Kenneth W. Kinosian,
Agnese Lagzda,
Russell J. Lochrie,
Michael W. May
, et al. (18 additional authors not shown)
Abstract:
The design and optimization of laser-Compton x-ray systems based on compact distributed charge accelerator structures can enable micron-scale imaging of disease and the concomitant production of beams of Very High Energy Electrons (VHEEs) capable of producing FLASH-relevant dose rates. The physics of laser-Compton x-ray scattering ensures that the scattered x-rays follow exactly the trajectory of…
▽ More
The design and optimization of laser-Compton x-ray systems based on compact distributed charge accelerator structures can enable micron-scale imaging of disease and the concomitant production of beams of Very High Energy Electrons (VHEEs) capable of producing FLASH-relevant dose rates. The physics of laser-Compton x-ray scattering ensures that the scattered x-rays follow exactly the trajectory of the incident electrons, thus providing a route to image-guided, VHEE FLASH radiotherapy. The keys to a compact architecture capable of producing both laser-Compton x-rays and VHEEs are the use of X-band RF accelerator structures which have been demonstrated to operate with over 100 MeV/m acceleration gradients. The operation of these structures in a distributed charge mode in which each radiofrequency (RF) cycle of the drive RF pulse is filled with a low-charge, high-brightness electron bunch is enabled by the illumination of a high-brightness photogun with a train of UV laser pulses synchronized to the frequency of the underlying accelerator system. The UV pulse trains are created by a patented pulse synthesis approach which utilizes the RF clock of the accelerator to phase and amplitude modulate a narrow band continuous wave (CW) seed laser. In this way it is possible to produce up to 10 μA of average beam current from the accelerator. Such high current from a compact accelerator enables production of sufficient x-rays via laser-Compton scattering for clinical imaging and does so from a machine of "clinical" footprint. At the same time, the production of 1000 or greater individual micro-bunches per RF pulse enables > 10 nC of charge to be produced in a macrobunch of < 100 ns. The design, construction, and test of the 100-MeV class prototype system in Irvine, CA is also presented.
△ Less
Submitted 7 August, 2024;
originally announced August 2024.
-
Segmented Terahertz Electron Accelerator and Manipulator (STEAM)
Authors:
Dongfang Zhang,
Arya Fallahi,
Michael Hemmer,
Xiaojun Wu,
Moein Fakhari,
Yi Hua,
Huseyin Cankaya,
Anne-Laure Calendron,
Luis E. Zapata,
Nicholas H. Matlis,
Franz X. Kärtner
Abstract:
Acceleration and manipulation of ultrashort electron bunches are the basis behind electron and X-ray devices used for ultrafast, atomic-scale imaging and spectroscopy. Using laser-generated THz drivers enables intrinsic synchronization as well as dramatic gains in field strengths, field gradients and component compactness, leading to shorter electron bunches, higher spatio-temporal resolution and…
▽ More
Acceleration and manipulation of ultrashort electron bunches are the basis behind electron and X-ray devices used for ultrafast, atomic-scale imaging and spectroscopy. Using laser-generated THz drivers enables intrinsic synchronization as well as dramatic gains in field strengths, field gradients and component compactness, leading to shorter electron bunches, higher spatio-temporal resolution and smaller infrastructures. We present a segmented THz electron accelerator and manipulator (STEAM) with extended interaction lengths capable of performing multiple high-field operations on the energy and phase-space of ultrashort bunches with moderate charge. With this single device, powered by few-microjoule, single-cycle, 0.3 THz pulses, we demonstrate record THz-device acceleration of >30 keV, streaking with <10 fs resolution, focusing with >2 kT/m strengths, compression to ~100 fs as well as real-time switching between these modes of operation. The STEAM device demonstrates the feasibility of future THz-based compact electron guns, accelerators, ultrafast electron diffractometers and Free-Electron Lasers with transformative impact.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz
Authors:
W. S. Graves,
J. Bessuille,
P. Brown,
S. Carbajo,
V. Dolgashev,
K. -H. Hong,
E. Ihloff,
B. Khaykovich,
H. Lin,
K. Murari,
E. A. Nanni,
G. Resta,
S. Tantawi,
L. E. Zapata,
F. X. Kärtner,
D. E. Moncton
Abstract:
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and RF photoinjector powered by a single ultrastable RF transmitter at x-…
▽ More
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and RF photoinjector powered by a single ultrastable RF transmitter at x-band RF frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. The entire accelerator is approximately 1 meter long and produces hard x-rays tunable over a wide range of photon energies. The colliding laser is a Yb:YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is $5 \times 10^{11}$ photons/second in a 5% bandwidth and the brilliance is $2 \times 10^{12}\mathrm{photons/(sec\ mm^2\ mrad^2\ 0.1\%)}$ in pulses with RMS pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.
△ Less
Submitted 9 October, 2014; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Multi-mJ, kHz, 2.1-$μ$m OPCPA for high-flux soft X-ray high-harmonic radiation
Authors:
Kyung-Han Hong,
Chien-Jen Lai,
Jonathas Siqueira,
Peter Krogen,
Jeffrey Moses,
Martin Smrz,
Luis E. Zapata,
Franz X. Kärtner
Abstract:
We report on a multi-mJ 2.1-$μ$m OPCPA system operating at a 1-kHz repetition rate, pumped by a picosecond cryogenic Yb:YAG pump laser, and the phase-matched high-flux high-harmonic soft X-ray generation.
We report on a multi-mJ 2.1-$μ$m OPCPA system operating at a 1-kHz repetition rate, pumped by a picosecond cryogenic Yb:YAG pump laser, and the phase-matched high-flux high-harmonic soft X-ray generation.
△ Less
Submitted 11 December, 2013;
originally announced December 2013.