-
Workshop on a future muon program at FNAL
Authors:
S. Corrodi,
Y. Oksuzian,
A. Edmonds,
J. Miller,
H. N. Tran,
R. Bonventre,
D. N. Brown,
F. Meot,
V. Singh,
Y. Kolomensky,
S. Tripathy,
L. Borrel,
M. Bub,
B. Echenard,
D. G. Hitlin,
H. Jafree,
S. Middleton,
R. Plestid,
F. C. Porter,
R. Y. Zhu,
L. Bottura,
E. Pinsard,
A. M. Teixeira,
C. Carelli,
D. Ambrose
, et al. (68 additional authors not shown)
Abstract:
The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e…
▽ More
The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.
△ Less
Submitted 11 September, 2023;
originally announced September 2023.
-
New Technologies for Discovery
Authors:
Z. Ahmed,
A. Apresyan,
M. Artuso,
P. Barry,
E. Bielejec,
F. Blaszczyk,
T. Bose,
D. Braga,
S. A. Charlebois,
A. Chatterjee,
A. Chavarria,
H. -M. Cho,
S. Dalla Torre,
M. Demarteau,
D. Denisov,
M. Diefenthaler,
A. Dragone,
F. Fahim,
C. Gee,
S. Habib,
G. Haller,
J. Hogan,
B. J. P. Jones,
M. Garcia-Sciveres,
G. Giacomini
, et al. (58 additional authors not shown)
Abstract:
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by hi…
▽ More
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.
△ Less
Submitted 10 August, 2019; v1 submitted 31 July, 2019;
originally announced August 2019.
-
Mu2e calorimeter readout system
Authors:
N. Atanov,
V. Baranov,
L. Baldini,
J. Budagov,
D. Caiulo,
F. Cei,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
F. D'Errico,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Faetti,
S. Giovannella,
S. Giudici,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
L. Lazzeri
, et al. (21 additional authors not shown)
Abstract:
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to o…
▽ More
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.
△ Less
Submitted 9 July, 2019;
originally announced July 2019.
-
The Mu2e calorimeter: quality assurance of production crystals and SiPMs
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
D. Caiulo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi
, et al. (12 additional authors not shown)
Abstract:
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples pre…
▽ More
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Design and status of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous ex…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
The Mu2e Calorimeter Final Technical Design Report
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane,
Y. Davydov,
S. Di Falco,
S. Donati,
E. Diociaiuti,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi
, et al. (15 additional authors not shown)
Abstract:
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout…
▽ More
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
Design, status and perspective of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
E. Diociaiuti,
M. Cordelli,
G. Corradi,
E. Danè,
Yu. Davydov,
S. Donati,
R. Donghia,
S. Di Falco,
B. Echenard,
L. Morescalchi,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker an…
▽ More
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.
△ Less
Submitted 18 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
The Mu2e undoped CsI crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigg…
▽ More
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.
△ Less
Submitted 22 February, 2018; v1 submitted 7 January, 2018;
originally announced January 2018.
-
Quality Assurance on a custom SiPMs array for the Mu2e experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain…
▽ More
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
The calorimeter of the Mu2e experiment at Fermilab
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dané,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data tak…
▽ More
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.
△ Less
Submitted 27 January, 2017;
originally announced January 2017.
-
Design and status of the Mu2e electromagnetic calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
R. Carosi,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane',
Yu. I. Davydov,
S. Di Falco,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic…
▽ More
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.
△ Less
Submitted 8 August, 2016;
originally announced August 2016.
-
Design, status and test of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
R. Carosi,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Danè,
Y. I. Davydov,
S. Di Falco,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with about 700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. These crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.
△ Less
Submitted 1 July, 2016; v1 submitted 17 June, 2016;
originally announced June 2016.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
The Physics of the B Factories
Authors:
A. J. Bevan,
B. Golob,
Th. Mannel,
S. Prell,
B. D. Yabsley,
K. Abe,
H. Aihara,
F. Anulli,
N. Arnaud,
T. Aushev,
M. Beneke,
J. Beringer,
F. Bianchi,
I. I. Bigi,
M. Bona,
N. Brambilla,
J. B rodzicka,
P. Chang,
M. J. Charles,
C. H. Cheng,
H. -Y. Cheng,
R. Chistov,
P. Colangelo,
J. P. Coleman,
A. Drutskoy
, et al. (2009 additional authors not shown)
Abstract:
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary…
▽ More
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary version of the Physics of the B Factories book. This uses the notation alpha, beta, gamma for the angles of the Unitarity Triangle. The nominal version uses the notation phi_1, phi_2 and phi_3. Please cite this work as Eur. Phys. J. C74 (2014) 3026.
△ Less
Submitted 31 October, 2015; v1 submitted 24 June, 2014;
originally announced June 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Mu2e Conceptual Design Report
Authors:
The Mu2e Project,
Collaboration,
:,
R. J. Abrams,
D. Alezander,
G. Ambrosio,
N. Andreev,
C. M. Ankenbrandt,
D. M. Asner,
D. Arnold,
A. Artikov,
E. Barnes,
L. Bartoszek,
R. H. Bernstein,
K. Biery,
V. Biliyar,
R. Bonicalzi,
R. Bossert,
M. Bowden,
J. Brandt,
D. N. Brown,
J. Budagov,
M. Buehler,
A. Burov,
R. Carcagno
, et al. (203 additional authors not shown)
Abstract:
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe…
▽ More
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.