Euclid. II. The VIS Instrument
Authors:
Euclid Collaboration,
M. Cropper,
A. Al-Bahlawan,
J. Amiaux,
S. Awan,
R. Azzollini,
K. Benson,
M. Berthe,
J. Boucher,
E. Bozzo,
C. Brockley-Blatt,
G. P. Candini,
C. Cara,
R. A. Chaudery,
R. E. Cole,
P. Danto,
J. Denniston,
A. M. Di Giorgio,
B. Dryer,
J. Endicott,
J. -P. Dubois,
M. Farina,
E. Galli,
L. Genolet,
J. P. D. Gow
, et al. (403 additional authors not shown)
Abstract:
This paper presents the specification, design, and development of the Visible Camera (VIS) on the ESA Euclid mission. VIS is a large optical-band imager with a field of view of 0.54 deg^2 sampled at 0.1" with an array of 609 Megapixels and spatial resolution of 0.18". It will be used to survey approximately 14,000 deg^2 of extragalactic sky to measure the distortion of galaxies in the redshift ran…
▽ More
This paper presents the specification, design, and development of the Visible Camera (VIS) on the ESA Euclid mission. VIS is a large optical-band imager with a field of view of 0.54 deg^2 sampled at 0.1" with an array of 609 Megapixels and spatial resolution of 0.18". It will be used to survey approximately 14,000 deg^2 of extragalactic sky to measure the distortion of galaxies in the redshift range z=0.1-1.5 resulting from weak gravitational lensing, one of the two principal cosmology probes of Euclid. With photometric redshifts, the distribution of dark matter can be mapped in three dimensions, and, from how this has changed with look-back time, the nature of dark energy and theories of gravity can be constrained. The entire VIS focal plane will be transmitted to provide the largest images of the Universe from space to date, reaching m_AB>24.5 with S/N >10 in a single broad I_E~(r+i+z) band over a six year survey. The particularly challenging aspects of the instrument are the control and calibration of observational biases, which lead to stringent performance requirements and calibration regimes. With its combination of spatial resolution, calibration knowledge, depth, and area covering most of the extra-Galactic sky, VIS will also provide a legacy data set for many other fields. This paper discusses the rationale behind the VIS concept and describes the instrument design and development before reporting the pre-launch performance derived from ground calibrations and brief results from the in-orbit commissioning. VIS should reach fainter than m_AB=25 with S/N>10 for galaxies of full-width half-maximum of 0.3" in a 1.3" diameter aperture over the Wide Survey, and m_AB>26.4 for a Deep Survey that will cover more than 50 deg^2. The paper also describes how VIS works with the other Euclid components of survey, telescope, and science data processing to extract the cosmological information.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Euclid. I. Overview of the Euclid mission
Authors:
Euclid Collaboration,
Y. Mellier,
Abdurro'uf,
J. A. Acevedo Barroso,
A. Achúcarro,
J. Adamek,
R. Adam,
G. E. Addison,
N. Aghanim,
M. Aguena,
V. Ajani,
Y. Akrami,
A. Al-Bahlawan,
A. Alavi,
I. S. Albuquerque,
G. Alestas,
G. Alguero,
A. Allaoui,
S. W. Allen,
V. Allevato,
A. V. Alonso-Tetilla,
B. Altieri,
A. Alvarez-Candal,
A. Amara,
L. Amendola
, et al. (1086 additional authors not shown)
Abstract:
The current standard model of cosmology successfully describes a variety of measurements, but the nature of its main ingredients, dark matter and dark energy, remains unknown. Euclid is a medium-class mission in the Cosmic Vision 2015-2025 programme of the European Space Agency (ESA) that will provide high-resolution optical imaging, as well as near-infrared imaging and spectroscopy, over about 14…
▽ More
The current standard model of cosmology successfully describes a variety of measurements, but the nature of its main ingredients, dark matter and dark energy, remains unknown. Euclid is a medium-class mission in the Cosmic Vision 2015-2025 programme of the European Space Agency (ESA) that will provide high-resolution optical imaging, as well as near-infrared imaging and spectroscopy, over about 14,000 deg^2 of extragalactic sky. In addition to accurate weak lensing and clustering measurements that probe structure formation over half of the age of the Universe, its primary probes for cosmology, these exquisite data will enable a wide range of science. This paper provides a high-level overview of the mission, summarising the survey characteristics, the various data-processing steps, and data products. We also highlight the main science objectives and expected performance.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
Result of the MICROSCOPE Weak Equivalence Principle test
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Joel Bergé,
Alain Robert,
Quentin Baghi,
Yves André,
Judicaël Bedouet,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Louis Demange,
Hansjoerg Dittus,
Océane Dhuicque,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh
, et al. (22 additional authors not shown)
Abstract:
The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation…
▽ More
The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation has been detected for two test masses, made from platinum and titanium alloys, in a sequence of 19 segments lasting from 13 to 198 hours down to the limit of the statistical error which is smaller than $10^{-14}$ for $ η({\rm{Ti, Pt}})$. Accumulating data from all segments leads to $η({\rm{Ti, Pt}}) =[-1.5\pm{}2.3{\rm (stat)}\pm{}1.5{\rm (syst)}] \times{}10^{-15}$ showing no EP violation at the level of $2.7\times{}10^{-15}$ if we combine stochastic and systematic errors quadratically. This represents an improvement of almost two orders of magnitude with respect to the previous best such test performed by the Eöt-Wash group. The reliability of this limit has been verified by comparing the free falls of two test masses of the same composition (platinum) leading to a null Eötvös parameter with a statistical uncertainty of $1.1\times{}10^{-15}$.
△ Less
Submitted 30 September, 2022;
originally announced September 2022.
-
MICROSCOPE: systematic errors
Authors:
Manuel Rodrigues,
Pierre Touboul1,
Gilles Metris,
Alain Robert,
Oceane Dhuicque,
Joel Berge,
Yves Andre,
Damien Boulanger,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Pascale Danto,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Vincent Lebat,
Francoise Liorzou,
Benjamin Pouilloux,
Pascal Prieur,
Serge Reynaud,
Patrizia Torresi
Abstract:
The MICROSCOPE mission aims to test the Weak Equivalence Principle (WEP) in orbit with an unprecedented precision of 10$^{-15}$ on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Syste…
▽ More
The MICROSCOPE mission aims to test the Weak Equivalence Principle (WEP) in orbit with an unprecedented precision of 10$^{-15}$ on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
MICROSCOPE instrument in-flight characterization
Authors:
Ratana Chhun,
Emilie Hardy,
Manuel Rodrigues,
Pierre Touboul,
Gilles Métris,
Damien Boulanger,
Bruno Christophe,
Pascale Danto,
Bernard Foulon,
Pierre-Yves Guidotti,
Phuong-Anh Huynh,
Vincent Lebat,
Françoise Liorzou,
Alain Robert
Abstract:
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subseq…
▽ More
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
△ Less
Submitted 12 May, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
MICROSCOPE instrument description and validation
Authors:
Françoise Liorzou,
Pierre Touboul,
Manuel Rodrigues,
Gilles Métris,
Yves André,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Pascale Danto,
Bernard Foulon,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Meike List,
Frank Löffler,
Benny Rievers,
Alain Robert,
Hanns Selig
Abstract:
Dedicated accelerometers have been developed for the MICROSCOPE mission taking into account the specific range of acceleration to be measured on board the satellite. Considering one micro-g and even less as the full range of the instrument, leads to a customized concept and a high performance electronics for the sensing and servo-actuations of the accelerometer test-masses. In addition to a very a…
▽ More
Dedicated accelerometers have been developed for the MICROSCOPE mission taking into account the specific range of acceleration to be measured on board the satellite. Considering one micro-g and even less as the full range of the instrument, leads to a customized concept and a high performance electronics for the sensing and servo-actuations of the accelerometer test-masses. In addition to a very accurate geometrical sensor core, a high performance electronics architecture provides the measurement of the weak electrostatic forces and torques applied to the test-masses. A set of capacitive sensors delivers the position and the attitude of the test-mass with respect to a very steady gold coated cage made in silica. The voltages applied on the electrodes surrounding each test-mass are finely controlled to generate the adequate electrical field and so the electrostatic pressures on the test-mass. This field maintains the test-mass motionless with respect to the instrument structure. Digital control laws are implemented in order to enable instrument operation flexibility and a weak position sensor noise. These electronics provide both the scientific data for MICROSCOPE's test of General Relativity and the data for the satellite drag-free and attitude control system (DFACS).
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
Updated design of the CMB polarization experiment satellite LiteBIRD
Authors:
H. Sugai,
P. A. R. Ade,
Y. Akiba,
D. Alonso,
K. Arnold,
J. Aumont,
J. Austermann,
C. Baccigalupi,
A. J. Banday,
R. Banerji,
R. B. Barreiro,
S. Basak,
J. Beall,
S. Beckman,
M. Bersanelli,
J. Borrill,
F. Boulanger,
M. L. Brown,
M. Bucher,
A. Buzzelli,
E. Calabrese,
F. J. Casas,
A. Challinor,
V. Chan,
Y. Chinone
, et al. (196 additional authors not shown)
Abstract:
Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will ac…
▽ More
Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the cosmic microwave background (CMB) by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34GHz and 448GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy's foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5Kelvin for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun-Earth Lagrangian point, L2, are planned for three years. An international collaboration between Japan, USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science (ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Space test of the Equivalence Principle: first results of the MICROSCOPE mission
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Françoise Liorzou,
Meike List,
Isabelle Panet,
Sandrine Pires
, et al. (9 additional authors not shown)
Abstract:
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different co…
▽ More
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different compositions (titanium and platinum alloys) on a quasi-circular trajectory around the Earth. This is realised by measuring the accelerations inferred from the forces required to maintain the two masses exactly in the same orbit. Any significant difference between the measured accelerations, occurring at a defined frequency, would correspond to the detection of a violation of the WEP, or to the discovery of a tiny new type of force added to gravity. MICROSCOPE's first results show no hint for such a difference, expressed in terms of Eötvös parameter $δ(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both 1$σ$ uncertainties) for a titanium and platinum pair of materials. This result was obtained on a session with 120 orbital revolutions representing 7\% of the current available data acquired during the whole mission. The quadratic combination of 1$σ$ uncertainties leads to a current limit on $δ$ of about $1.3\times{}10^{-14}$.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
The MICROSCOPE mission: first results of a space test of the Equivalence Principle
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Claude Gageant,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh,
Henri Inchauspe,
Patrick Kayser,
Stéphanie Lala
, et al. (18 additional authors not shown)
Abstract:
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of…
▽ More
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of the Equivalence Principle, or to the discovery of a new long-range force. Analysis of the first data gives $δ\rm{(Ti,Pt)}= [-1 \pm 9 (\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$σ$ statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations.
△ Less
Submitted 6 December, 2017; v1 submitted 4 December, 2017;
originally announced December 2017.