-
FALCO simulations of high-contrast polarimetry with the Nancy Grace Roman Space Telescope Coronagraph Instrument
Authors:
David S. Doelman,
Hanae Belaouchi,
A. J. Riggs,
Bertrand Mennesson,
Mireille Ouellet,
Rob G. van Holstein,
Jeroen Rietjens,
Henk Hoevers,
Frans Snik
Abstract:
The Coronagraph Instrument of the Nancy Grace Roman Space Telescope (Roman Coronagraph) will be capable of both total intensity and polarization measurements of circumstellar disks. The polarimetric performance is impacted by polarization effects introduced by all mirrors before the Wollaston prisms. In this paper, we aim to characterize these effects for the Roman Coronagraph in bands 1 and 4 usi…
▽ More
The Coronagraph Instrument of the Nancy Grace Roman Space Telescope (Roman Coronagraph) will be capable of both total intensity and polarization measurements of circumstellar disks. The polarimetric performance is impacted by polarization effects introduced by all mirrors before the Wollaston prisms. In this paper, we aim to characterize these effects for the Roman Coronagraph in bands 1 and 4 using the FALCO and PROPER packages. We simulate the effect of polarization aberrations that impact the polarimetric contrast and the instrumental polarization effects to study the polarimetric accuracy. We include spacecraft rolls, but leave out systematic camera noise. We find that polarimetric differential imaging (PDI) improves the contrast by a factor of six. The PDI contrast of $\sim 8 \times 10^{-11}$ is limited by polarized speckles from instrumental polarization effects and polarization aberrations. By injecting polarized companions with at various contrast levels and demodulating their polarimetric signal, we recover their source Stokes vector within 2%.
△ Less
Submitted 5 September, 2023;
originally announced September 2023.
-
The development of a testbed for the X-ray Interferometer mission
Authors:
Roland den Hartog,
Phil Uttley,
Richard Willingale,
Henk Hoevers,
Jan-Willem den Herder,
Michael Wise
Abstract:
An X-ray Interferometer (XRI) has recently been proposed as a theme for ESA's Voyage 2050 planning cycle, with the eventual goal to observe the X-ray sky with an unprecedented angular resolution better than 1 micro arcsec (5 prad) [1]. A scientifically very interesting mission is possible on the basis of a single spacecraft [2], owing to the compact 'telephoto' design proposed earlier by Willingal…
▽ More
An X-ray Interferometer (XRI) has recently been proposed as a theme for ESA's Voyage 2050 planning cycle, with the eventual goal to observe the X-ray sky with an unprecedented angular resolution better than 1 micro arcsec (5 prad) [1]. A scientifically very interesting mission is possible on the basis of a single spacecraft [2], owing to the compact 'telephoto' design proposed earlier by Willingale [3]. Between the practical demonstration of X-ray interferometry at 1 keV by Cash et al. [4] with a 1 mm baseline and 0.1 arcsec effective resolution to a mission flying an interferometer with a baseline of one or more meters, an effective collecting area of square meters and micro arcsec resolution lie many milestones. The first important steps to scale up from a laboratory experiment to a viable mission concept will have to be taken on a scalable and flexible testbed set-up. Such a testbed cannot singularly focus on the optical aspects, but should simultaneously address the thermal and mechanical stability of the interferometer. A particular challenge is the coherent X-ray source, which should provide a wavefront at the entrance of the interferometer that is transversely coherent over a distance at least equal to the baseline, and bright enough. In this paper, we will explore the build-up of a testbed in several stages, with increasing requirements on optical quality and associated thermo-mechanical control and source sophistication, with the intent to guide the technological development of X-ray interferometry from the lab to space in a sequence of achievable milestones.
△ Less
Submitted 16 July, 2021;
originally announced July 2021.
-
A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Marcel Bruijn,
Jan R. Gao,
Roland den Hartog,
Richard Hijmering,
Henk Hoevers,
Pourya Khosropanah,
Jan van der Kuur,
Anoton van der Linden,
Marcel Lindeman,
Marcel Ridder
Abstract:
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arra…
▽ More
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
△ Less
Submitted 9 April, 2016;
originally announced April 2016.
-
AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz
Authors:
Luciano Gottardi,
Marcel Bruijn,
Jan-R. Gao,
Roland den Hartog,
Richard Hijmering,
Henk Hoevers,
Pourya Khosropanah,
Piet de Korte,
Jan van der Kuur,
Mark Lindeman,
Marcel Ridder
Abstract:
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to…
▽ More
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We conclude the paper by comparing the performance of a $4 \cdot 10^{-19} W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
△ Less
Submitted 9 April, 2016;
originally announced April 2016.
-
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Marcel Bruijn,
Jan-R. Gao,
Roland den Hartog,
Richard Hijmering,
Henk Hoevers,
Pourya Khosropanah,
Alex Kozorezov,
Jan van der Kuur,
Anton van der Linden,
Marcel Ridder
Abstract:
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based…
▽ More
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier and high- Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.
△ Less
Submitted 3 April, 2016;
originally announced April 2016.
-
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Didier Barret,
Marcel P. Bruijn,
Roland H. den Hartog,
Jan-Willem den Herder,
Henk F. C. Hoevers,
Mikko Kiviranta,
Jan van der Kuur,
Anton J. van der Linden,
Brian D. Jackson,
Madu Jambunathan,
Marcel L. Ridder
Abstract:
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with diff…
▽ More
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.
△ Less
Submitted 2 April, 2016;
originally announced April 2016.
-
Fluctuation superconductivity limited noise in a transition-edge sensor
Authors:
A. Luukanen,
K. M. Kinnunen,
A. K. Nuottajärvi,
H. F. C. Hoevers,
W. M. Bergmann Tiest,
J. P. Pekola
Abstract:
In order to investigate the origin of the until now unaccounted excess noise and to minimize the uncontrollable phenomena at the transition in X-ray microcalorimeters we have developed superconducting transition-edge sensors into an edgeless geometry, the so-called Corbino disk (CorTES), with superconducting contacts in the centre and at the outer perimeter. The measured rms current noise and it…
▽ More
In order to investigate the origin of the until now unaccounted excess noise and to minimize the uncontrollable phenomena at the transition in X-ray microcalorimeters we have developed superconducting transition-edge sensors into an edgeless geometry, the so-called Corbino disk (CorTES), with superconducting contacts in the centre and at the outer perimeter. The measured rms current noise and its spectral density can be modeled as resistance noise resulting from fluctuations near the equilibrium superconductor-normal metal boundary
△ Less
Submitted 29 April, 2003; v1 submitted 18 February, 2003;
originally announced February 2003.