-
Compact Metasurface Terahertz Spectrometer
Authors:
Wenye Ji,
Jin Chang,
Behnam Mirzaei,
Marcel Ridder,
Willem Jellema,
Wilt Kao,
Alan Lee,
Jian Rong Gao,
Paul Urbach,
Aurele J. L. Adam
Abstract:
The electromagnetic spectrum in the terahertz frequency region is of significant importance for understanding the formation and evolution of galaxies and stars throughout the history of the universe and the process of planet formation. Within the star forming clouds the constituent atoms and molecules are excited to produce characteristic emission and absorption lines, many of which happen at the…
▽ More
The electromagnetic spectrum in the terahertz frequency region is of significant importance for understanding the formation and evolution of galaxies and stars throughout the history of the universe and the process of planet formation. Within the star forming clouds the constituent atoms and molecules are excited to produce characteristic emission and absorption lines, many of which happen at the terahertz frequencies. Thus, detecting the spectral signatures as unique fingerprints of molecules and atoms require terahertz spectrometers, which need to be operated in a space observatory because of the water vapor absorption in the earth atmosphere. However, current terahertz spectrometers face several challenges that limit their performances and applications, including a low resolution, limited bandwidth, large volume, and complexity. In this paper, we address the last two issues by demonstrating a concept of a compact terahertz spectrometer using metasurface. We start by modelling, designing, and fabricating a metasurface, aiming to optimize its performance within a band from 1.7 to 2.5 THz. Next, we make use of an array of quantum cascade lasers that operate at slightly different frequencies around 2.1 THz to validate the performance of the spectrometer. Finally, we apply the spectrum inversion method to analyse the measured data to confirm a resolution R of at least 273. Our results demonstrated a miniaturized terahertz spectrometer concept successfully.
△ Less
Submitted 5 September, 2023;
originally announced September 2023.
-
Radio detections of two unusual cataclysmic variables in the VLA Sky Survey
Authors:
Margaret E Ridder,
Craig O Heinke,
Gregory R Sivakoff,
Andrew K Hughes
Abstract:
We report two new radio detections of cataclysmic variables (CVs), and place them in context with radio and X-ray detections of other CVs. We detected QS Vir, a low accretion-rate CV; V2400 Oph, a diskless intermediate polar (IP); and recovered the polar AM Her in the Very Large Array Sky Survey (VLASS) 2-4 GHz radio images. The radio luminosities of these systems are higher than typically expecte…
▽ More
We report two new radio detections of cataclysmic variables (CVs), and place them in context with radio and X-ray detections of other CVs. We detected QS Vir, a low accretion-rate CV; V2400 Oph, a diskless intermediate polar (IP); and recovered the polar AM Her in the Very Large Array Sky Survey (VLASS) 2-4 GHz radio images. The radio luminosities of these systems are higher than typically expected from coronal emission from stars of similar spectral types, and neither system is expected to produce jets, leaving the origin of the radio emission a puzzle. The radio emission mechanism for these two CVs may be electron-cyclotron maser emission, synchrotron radiation, or a more exotic process. We compile published radio detections of CVs, and X-ray measurements of these CVs, to illustrate their locations in the radio - X-ray luminosity plane, a diagnostic tool often used for X-ray binaries, active galactic nuclei, and radio stars. Several radio-emitting CVs, including these two newly detected CVs, seem to lie near the principal radio/X-ray track followed by black hole X-ray binaries (BHXBs) at low luminosity, suggesting additional complexity in classifying unknown systems using their radio and X-ray luminosities alone.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Simulation and Measurement of Out-of-Band Resonances for the FDM Readout of a TES Bolometer
Authors:
Amin Aminaei,
Hiroki Akamatsu,
Ad Nieuwenhuizen,
Davide Vaccaro,
Qian Wang,
Damian Audley,
Pourya Khosropanah,
Alec McCalden,
Dick Boersma,
Marcel Ridder,
Saad Ilyas,
Jan van der Kuur,
Gert de Lange
Abstract:
With applications in cosmology, infrared astronomy and CMB survey, frequency-division multiplexing (FDM) proved to be a viable readout for transition-edge sensors (TES). We investigate the occurrence of out-of-band resonances (OBR) which could constrain the bandwidth of the FDM readout of TES bolometers. The study includes SPICE modeling of the entire setup including the cryogenic harness, LC filt…
▽ More
With applications in cosmology, infrared astronomy and CMB survey, frequency-division multiplexing (FDM) proved to be a viable readout for transition-edge sensors (TES). We investigate the occurrence of out-of-band resonances (OBR) which could constrain the bandwidth of the FDM readout of TES bolometers. The study includes SPICE modeling of the entire setup including the cryogenic harness, LC filters, Superconducting Quantum Interference Device (SQUID) and room-temperature amplifier. Simulation results show that the long harness (for flight model) could cause multiple reflections that generate repetitive spikes in the spectrum. Peaks of the OBR are mainly due to the parasitic capacitances at the input of SQUID. Implementing a low-pass RC circuit (snubber) at the input of the SQUID dampened the OBR. As a result, the first peak only appears around 20 MHz which is a safe margin for the 1 MHz-3.8 MHz FDM in use in the prototype readout. Using a spectrum analyzer and broadband LNAs,we also measured the OBR for the prototype FDM readout in the lab up to 500 MHz. The measurement was conducted at temperatures of 50 mK and 4 K and for various biasing of the DC SQUID. It turns out that OBR are more intense at 50 mK and are caused by the harness impedance mismatch rather than the SQUID. Simulation codes and supporting materials are available at https://github.com/githubamin/LT-Spice-Simulation-of-FDM-readout.
△ Less
Submitted 8 February, 2023;
originally announced February 2023.
-
Performance of the SRON Ti/Au Transition Edge Sensor X-ray Calorimeters
Authors:
Martin de Wit,
Luciano Gottardi,
Kenichiro Nagayoshi,
Hiroki Akamatsu,
Marcel P. Bruijn,
Marcel L. Ridder,
Emanuele Taralli,
Davide Vaccaro,
Jian-Rong Gao,
Jan-Willem A. den Herder
Abstract:
In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of several thousand transition-edge sensors (TESs) with a proposed energy resolution of 2.5 eV for photon energies up to 7 keV. At SRON we develop the backup TES…
▽ More
In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of several thousand transition-edge sensors (TESs) with a proposed energy resolution of 2.5 eV for photon energies up to 7 keV. At SRON we develop the backup TES array based on Ti/Au bilayers with a transition temperature just below 100 mK. In this contribution we will give a broad overview of the properties and capabilities of these state-of-the-art detectors. Over the years we have fabricated and studied a large number of detectors with various geometries, providing us with a good understanding of how to precisely control the properties of our detectors. We are able to accurately vary the most important detector properties, such as the normal resistance, thermal conductance and critical temperature. This allows us to finely tune our detectors to meet the demands of various applications. The detectors have demonstrated excellent energy resolutions of below 1.8 eV for 5.9 keV X-rays. By tuning the properties of the devices, they can be optimally matched to various read-out schemes using both AC and DC biasing. The next step is to increase the size of our TES arrays from our current kilo-pixel arrays towards the full-sized array for X-IFU.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
Susceptibility study of TES micro-calorimeters for X-ray spectroscopy under FDM readout
Authors:
Davide Vaccaro,
Hiroki Akamatsu,
Luciano Gottardi,
Jan van der Kuur,
Emanuele Taralli,
Martin de Wit,
Marcel P. Bruijn,
Roland den Hartog,
Mikko Kiviranta,
Anton J. van der Linden,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Sven Visser,
Brian D. Jackson,
Jian-Rong Gao,
Ruud W. M. Hoogeveen,
Jan-Willem A. den Herder
Abstract:
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produ…
▽ More
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument, showing the compliance of the measured sensitivities. We find in particular that FDM is intrinsically insensitive to the magnetic field because of TES design and AC readout.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
Mitigation of the Magnetic Field Susceptibility of Transition Edge Sensors using a Superconducting Groundplane
Authors:
Martin de Wit,
Luciano Gottardi,
Marcel L. Ridder,
Kenichiro Nagayoshi,
Emanuele Taralli,
Hiroki Akamatsu,
Davide Vaccaro,
Jan-Willem A. den Herder,
Marcel P. Bruijn,
Jian-Rong Gao
Abstract:
Transition edge sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus intrinsically sensitive to magnetic fields. Conventionally the detectors are shielded from stray magnetic fields using external magnetic shields. However, in particular for…
▽ More
Transition edge sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus intrinsically sensitive to magnetic fields. Conventionally the detectors are shielded from stray magnetic fields using external magnetic shields. However, in particular for applications with strict limits on the available space and mass of an instrument, external magnetic shields might not be enough to obtain the required shielding factors or field homogeneity. Additionally, these shields are only effective for magnetic fields generated external to the TES array, and are ineffective to mitigate the impact of internally generated magnetic fields. Here we present an alternative shielding method based on a superconducting groundplane deposited directly on the backside of the silicon nitride membrane on which the TESs are located. We demonstrate that this local shielding for external magnetic fields has a shielding factor of at the least ~ 75, and is also effective at reducing internal self-induced magnetic fields, as demonstrated by measurements and simulation of the eddy current losses in our AC biased detectors. Measurements of 5.9 keV X-ray photons show that our shielded detectors have a high resilience to external magnetic fields, showing no degradation of the energy resolution or shifts of the energy scale calibration for fields of several microTesla, values higher than expected in typical real-world applications.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
The Time Domain Spectroscopic Survey: Changing-Look Quasar Candidates from Multi-Epoch Spectroscopy in SDSS-IV
Authors:
Paul J. Green,
Lina Pulgarin-Duque,
Scott F. Anderson,
Chelsea L. MacLeod,
Michael Eracleous,
John J. Ruan,
Jessie Runnoe,
Matthew Graham,
Benjamin R. Roulston,
Donald P. Schneider,
Austin Ahlf,
Dmitry Bizyaev,
Joel R. Brownstein,
Sonia Joesephine del Casal,
Sierra A. Dodd,
Daniel Hoover,
Cayenne Matt,
Andrea Merloni,
Kaike Pan,
Arnulfo Ramirez,
Margaret Ridder
Abstract:
Active galactic nuclei (AGN) can vary significantly in their rest-frame optical/UV continuum emission, and with strong associated changes in broad line emission, on much shorter timescales than predicted by standard models of accretion disks around supermassive black holes. Most such ``changing-look'' or "changing-state" AGN -- and at higher luminosities, changing-look quasars (CLQs) -- have been…
▽ More
Active galactic nuclei (AGN) can vary significantly in their rest-frame optical/UV continuum emission, and with strong associated changes in broad line emission, on much shorter timescales than predicted by standard models of accretion disks around supermassive black holes. Most such ``changing-look'' or "changing-state" AGN -- and at higher luminosities, changing-look quasars (CLQs) -- have been found via spectroscopic follow-up of known quasars showing strong photometric variability. The Time Domain Spectroscopic Survey of SDSS-IV includes repeat spectroscopy of large numbers of previously-known quasars, many selected irrespective of photometric variability, and with spectral epochs separated by months to decades. Our visual examination of these repeat spectra for strong broad line variability yielded 61 newly-discovered CLQ candidates. We quantitatively compare spectral epochs to measure changes in continuum and H$β$ broad line emission, finding 19 CLQs, of which 15 are newly-recognized. The parent sample includes only broad line quasars, so our study tends to find objects that have dimmed, i.e., turn-off CLQs. However, we nevertheless find 4 turn-on CLQs that meet our criteria, albeit with broad lines in both dim and bright states. We study the response of H$β$ and MgII emission lines to continuum changes. The Eddington ratios of CLQs are low, and/or their H$β$ broad line width is large relative to the overall quasar population. Repeat quasar spectroscopy in the upcoming SDSS-V Black Hole Mapper program will reveal significant numbers of CLQs, enhancing our understanding of the frequency and duty-cycle of such strong variability, and the physics and dynamics of the phenomenon.
△ Less
Submitted 27 May, 2022; v1 submitted 22 January, 2022;
originally announced January 2022.
-
Thermal crosstalk of X-ray transition-edge sensor micro-calorimeters under frequency domain multiplexing readout
Authors:
Davide Vaccaro,
Hiroki Akamatsu,
Marcel P. Bruijn,
Luciano Gottardi,
Roland den Hartog,
Jan van der Kuur,
A. J. van der Linden,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Emanuele Taralli,
Martin de Wit,
Jian-Rong Gao,
Ruud W. M. Hoogeveen,
Jan-Willem A. den Herder
Abstract:
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray puls…
▽ More
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray pulse amplitudes. The crosstalk ratios (CR) for our detectors are compliant with the requirements for future X-ray space missions, such as Athena X-IFU (CR$< 10^{-3}$ for first-neighbour pixels): we measured a nearest-neighbour thermal crosstalk ratio at a level of $10^{-4}$, with a highest crosstalk ratio of $4\times 10^{-4}$ for the kilo-pixel array (worst case, center of array) and $1\times 10^{-4}$ for the 8$\times$8 array, with a margin of improvement achievable by optimizing the Cu metallization and the width of the Si supporting structures (muntins) in the backside of the TES array chip. Based on the measured crosstalk ratios, we have estimated the impact on the spectral resolution by means of noise equivalent power (NEP) considerations and a Monte Carlo simulation, finding an average degradation in quadrature of less than 40~meV, compliant with the < 0.2~eV requirement for Athena X-IFU.
△ Less
Submitted 24 November, 2021;
originally announced November 2021.
-
Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers
Authors:
H. Akamatsu,
D. Vaccaro,
L. Gottardi,
J. van der Kuur,
C. P. de Vries,
M. Kiviranta,
K. Ravensberg,
M. D'Andrea,
E. Taralli,
M. de Wit,
M. P. Bruijn,
P. van der Hulst,
R. H. den Hartog,
B-J. van Leeuwen,
A. J. van der Linden,
A. J McCalden,
K. Nagayoshi,
A. C. T. Nieuwenhuizen,
M. L. Ridder,
S. Visser,
P. van Winden,
J. R. Gao,
R. W. M. Hoogeveen,
B. D. Jackson,
J-W. A. den Herder
Abstract:
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum inte…
▽ More
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed X-ray spectral resolutions $@$ 5.9 keV are $ΔE_{\rm 31 pix ~MUX}=2.14\pm0.03$ eV and $ΔE_{\rm 37 pix ~MUX}=2.23\pm0.03$ eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution and to increase the number of multiplexed TESs, and to open up applications for TES X-ray microcalorimeters.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Impact of the absorber coupling design for Transition Edge Sensor X-ray Calorimeters
Authors:
M. de Wit,
L. Gottardi,
E. Taralli,
K. Nagayoshi,
M. L. Ridder,
H. Akamatsu,
M. P. Bruijn,
R. W. M. Hoogeveen,
J. van der Kuur,
K. Ravensberg,
D. Vaccaro,
J-R. Gao,
J-W. A. den Herder
Abstract:
Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power. To reach these demanding requirements, every aspect of the TES design has to be optimized. Here we present the experimental results of tests on different device…
▽ More
Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power. To reach these demanding requirements, every aspect of the TES design has to be optimized. Here we present the experimental results of tests on different devices where the coupling between the x-ray absorber and the TES sensor is varied. In particular, we look at the effects of the diameter of the coupling stems and the distance between the stems and the TES bilayer. Based on measurements of the AC complex impedance and noise, we observe a reduction in the excess noise as the spacing between the absorber stem and the bilayer is decreased. We identify the origin of this excess noise to be internal thermal fluctuation noise between the absorber stem and the bilayer. Additionally, we see an impact of the coupling on the superconducting transition in the appearance of kinks. Our observations show that these unwanted structures in the transition shape can be avoided with careful design of the coupling geometry. Also the stem diameter appears to have a significant impact on the smoothness of the TES transition. This observation is still poorly understood, but is of great importance for both AC and DC biased TESs.
△ Less
Submitted 20 July, 2021;
originally announced July 2021.
-
High Aspect Ratio Transition Edge Sensors for X-ray Spectrometry
Authors:
M. de Wit,
L. Gottardi,
E. Taralli,
K. Nagayoshi,
M. L. Ridder,
H. Akamatsu,
M. P. Bruijn,
M. D'Andrea,
J. van der Kuur,
K. Ravensberg,
D. Vaccaro,
S. Visser,
J. R. Gao,
J. -W. A. den Herder
Abstract:
We are developing large TES arrays in combination with FDM readout for the next generation of X-ray space observatories. For operation under AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help to mitigate non-ideal behaviour due to the weak-link effect. In this paper, we present a full characterization of a TES array containi…
▽ More
We are developing large TES arrays in combination with FDM readout for the next generation of X-ray space observatories. For operation under AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help to mitigate non-ideal behaviour due to the weak-link effect. In this paper, we present a full characterization of a TES array containing five different device geometries, with aspect ratios (width:length) ranging from 1:2 up to 1:6. The complex impedance of all geometries is measured in different bias configurations to study the evolution of the small-signal limit superconducting transition parameters, as well as the excess noise. We show that high aspect ratio devices with properly tuned critical temperatures (around 90 mK) can achieve excellent energy resolution, with an array average of 2.03 +- 0.17 eV at 5.9 keV and a best achieved resolution of 1.63 +- 0.17 eV. This demonstrates that AC-biased TESs can achieve a very competitive performance compared to DC-biased TESs. The results have motivated a push to even more extreme device geometries currently in development.
△ Less
Submitted 20 July, 2021;
originally announced July 2021.
-
TiAu TES 32$\times$32 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies
Authors:
E. Taralli,
M. D'Andrea,
L. Gottardi,
K. Nagayoshi,
M. Ridder,
S. Visser,
M. de Wit,
D. Vaccaro,
H. Akamatsu,
K. Ravensberg,
R. Hoogeveen,
M. Bruijn,
J. R. Gao
Abstract:
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led…
▽ More
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 $μ$m$^2$ TiAu TESs, which have \textcolor{black}{a 2.3 $μ$m} thick Au absorber for X-ray photons. The pixels have a typical normal resistance $R_\mathrm{n}$ = 121 m$Ω$ and a critical temperature $T_\mathrm{c}\sim$ 90 mK. We performed extensive measurements on 60 pixels out of the array in order to show the uniformity of the array. We obtained an energy resolutions between 2.4 and 2.6 eV (FWHM) at 5.9 keV, measured in a single-pixel mode at AC bias frequencies ranging from 1 to 5 MHz, with a frequency domain multiplexing (FDM) readout system, which is developed at SRON/VTT. We also present the detector energy resolution at X-ray with different photon energies generated by a modulated external X-ray source from 1.45 keV up to 8.9 keV. Multiplexing readout across several pixels has also been performed to evaluate the impact of the thermal crosstalk to the instrument's energy resolution budget requirement. This value results in a derived requirement, for the first neighbour, that is less than 1$\times$10$^{-3}$ when considering the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 5.9 keV)
△ Less
Submitted 19 February, 2021;
originally announced February 2021.
-
Performance and uniformity of a kilo-pixel array of Ti/Au transition-edge sensor microcalorimeters
Authors:
E. Taralli,
M. D'Andrea,
L. Gottardi,
K. Nagayoshi,
M. L. Ridder,
M. de Wit,
D. Vaccaro,
H. Akamatsu,
M. P. Bruijn,
J. R. Gao
Abstract:
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $ΔE$ < 3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays for use in future laboratory and space-based X-ray astrophysics experiments and ground-ba…
▽ More
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $ΔE$ < 3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays for use in future laboratory and space-based X-ray astrophysics experiments and ground-based spectrometers.
In this contribution we report on the development and the characterization of a uniform 32$\times$32 pixel array with 140$\times$30 $μ$m$^2$ Ti/Au TESs with Au X-ray absorber. We report upon extensive measurements on 60 pixels in order to show the uniformity of our large TES array. The averaged critical temperature is $T_\mathrm{c}$ = 89.5$\pm$0.5 mK and the variation across the array ($\sim$1 cm) is less than 1.5 mK. We found a large region of detector's bias points between 20\% and 40\% of the normal-state resistance where the energy resolution is constantly lower than 3 eV. In particular, results show a summed X-ray spectral resolution $ΔE_\mathrm{FWHM}$ = 2.50$\pm$0.04 eV at a photon energy of 5.9 keV, measured in a single-pixel mode using a frequency domain multiplexing (FDM) readout system developed at SRON/VTT at bias frequencies ranging from 1 to 5 MHz. Moreover we compare the logarithmic resistance sensitivity with respect to temperature and current ($α$ and $β$ respectively) and their correlation with the detector's noise parameter $M$, showing an homogeneous behaviour for all the measured pixels in the array.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
Single pixel performance of a 32$\times$32 Ti/Au TES array with broadband X-ray spectra
Authors:
Matteo D'Andrea,
Emanuele Taralli,
Hiroki Akamatsu,
Luciano Gottardi,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Davide Vaccaro,
Cor P. de Vries,
Martin de Wit,
Marcel P. Bruijn,
Ruud W. M. Hoogeveen,
Jian-Rong Gao
Abstract:
We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV)…
▽ More
We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$α$ at 5.4 keV and Cu-K$α$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calibration accuracy better than $\sim$ 0.5 eV in the 5.4 - 8.9 keV energy range. Then, we present the measured energy resolution at the different energies (best single pixel performance: $Δ$E$_{FWHM}$ = 2.40 $\pm$ 0.09 eV @ 5.4 keV; 2.53 $\pm$ 0.10 eV @ 5.9 keV; 2.78 $\pm$ 0.16 eV @ 8.0 keV), investigating also the performance dependency from the pixel bias frequency and the count rate. Thanks to long background measurements ($\sim$ 1 day), we finally detected also the Al-K$α$ line at 1.5 keV, generated by fluorescence inside the experimental setup. We analyzed this line to obtain a first assessment of the single-pixel performance also at low energy ($Δ$E$_{FWHM}$ = 1.91 eV $\pm$ 0.21 eV @ 1.5 keV), and to evaluate the linearity of the detector response in a large energy band (1.5 - 8.9 keV).
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
Frequency Shift Algorithm: Application to a Frequency-Domain Multiplexing Readout of X-ray Transition-Edge Sensor Microcalorimeters
Authors:
D. Vaccaro,
H. Akamatsu,
J. van der Kuur,
P. van der Hulst,
A. C. T. Nieuwenhuizen,
P. van Winden,
L. Gottardi,
R. den Hartog,
M. P. Bruijn,
M. D'Andrea,
J. R. Gao,
J. W. A. den Herder,
R. W. M. Hoogeveen,
B. Jackson,
A. J. van der Linden,
K. Nagayoshi,
K. Ravensberg,
M. L. Ridder,
E. Taralli,
M. de Wit
Abstract:
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes howev…
▽ More
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes however pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which nonetheless would significantly affect the effective bias circuit and the detector spectral performance. In this paper we present a frequency shift algorithm (FSA) to allow off-resonance readout of TES's while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of a X-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the X-ray performance is consistent with the single-pixel, on-resonance level.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Cataclysmic Variables in the First Year of the Zwicky Transient Facility
Authors:
Paula Szkody,
Brooke Dicenzo,
Anna Y. Q. Ho,
Lynne A. Hillenbrand,
Jan van Roestel,
Margaret Ridder,
Isabel DeJesus Lima,
Melissa L. Graham,
Eric C. Bellm,
Kevin Burdge,
Thomas Kupfer,
Thomas A. Prince,
Frank J. Masci,
Przemyslaw J. Mroz,
V. Zach Golkhou,
Michael Coughlin,
Virginia A. Cunningham,
Richard Dekany,
Matthew J. Graham,
David Hale,
David Kaplan,
Mansi M. Kasliwal,
Adam A. Miller,
James D. Neill,
Maria T. Patterson
, et al. (3 additional authors not shown)
Abstract:
Using selection criteria based on amplitude, time and color, we have identified 329 objects as known or candidate cataclysmic variable (CVs) during the first year of testing and operation of the Zwicky Transient Facility (ZTF). Of these, 90 are previously confirmed CVs, 218 are strong candidates based on the shape and color of their light curves obtained during 3-562 days of observations, and the…
▽ More
Using selection criteria based on amplitude, time and color, we have identified 329 objects as known or candidate cataclysmic variable (CVs) during the first year of testing and operation of the Zwicky Transient Facility (ZTF). Of these, 90 are previously confirmed CVs, 218 are strong candidates based on the shape and color of their light curves obtained during 3-562 days of observations, and the remaining 21 are possible CVs but with too few data points to be listed as good candidates. Almost half the strong candidates are within 10 deg of the galactic plane, in contrast to most other large surveys which have avoided crowded fields. The available Gaia parallaxes are consistent with sampling the low mass transfer CVs, as predicted by population models. Our followup spectra have confirmed Balmer/helium emission lines in 27 objects, with four showing high excitation HeII emission, including candidates for an AM CVn, a polar and an intermediate polar. Our results demonstrate that a complete survey of the galactic plane is needed to accomplish an accurate determination of the number of CVs existing in the Milky Way.
△ Less
Submitted 19 February, 2020;
originally announced February 2020.
-
The SAFARI Detector System
Authors:
Michael D. Audley,
Gert de Lange,
Jian-Rong Gao,
Brian D. Jackson,
Richard A. Hijmering,
Marcel L. Ridder,
Marcel P. Bruijn,
Peter R. Roelfsema,
Peter A. R. Ade,
Stafford Withington,
Charles M. Bradford,
Neal A. Trappe
Abstract:
We give an overview of the baseline detector system for SAFARI, the prime focal-plane instrument on board the proposed space infrared observatory, SPICA. SAFARI's detectors are based on superconducting Transition Edge Sensors (TES) to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to read out the tot…
▽ More
We give an overview of the baseline detector system for SAFARI, the prime focal-plane instrument on board the proposed space infrared observatory, SPICA. SAFARI's detectors are based on superconducting Transition Edge Sensors (TES) to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to read out the total of ~3500 detectors we use frequency domain multiplexing (FDM) with baseband feedback. In each multiplexing channel, a two-stage SQUID preamplifier reads out 160 detectors. We describe the detector system and discuss some of the considerations that informed its design.
△ Less
Submitted 18 July, 2018; v1 submitted 17 July, 2018;
originally announced July 2018.
-
Optical performance of prototype horn-coupled TES bolometer arrays for SAFARI
Authors:
Michael D. Audley,
Gert de Lange,
Jian-Rong Gao,
Pourya Khosropanah,
Richard Hijmering,
Marcel L Ridder
Abstract:
The SAFARI Detector Test Facility is an ultra-low background optical testbed for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for SAFARI, the grating spectrometer on board the proposed SPICA satellite. The testbed contains internal cold and hot black-body illuminators and a light-pipe for illumination with an external source. We have added reimaging optics to facilitate arra…
▽ More
The SAFARI Detector Test Facility is an ultra-low background optical testbed for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for SAFARI, the grating spectrometer on board the proposed SPICA satellite. The testbed contains internal cold and hot black-body illuminators and a light-pipe for illumination with an external source. We have added reimaging optics to facilitate array optical measurements. The system is now being used for optical testing of prototype detector arrays read out with frequency-domain multiplexing. We present our latest optical measurements of prototype arrays and discuss these in terms of the instrument performance.
△ Less
Submitted 24 August, 2016;
originally announced August 2016.
-
A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Marcel Bruijn,
Jan R. Gao,
Roland den Hartog,
Richard Hijmering,
Henk Hoevers,
Pourya Khosropanah,
Jan van der Kuur,
Anoton van der Linden,
Marcel Lindeman,
Marcel Ridder
Abstract:
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arra…
▽ More
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
△ Less
Submitted 9 April, 2016;
originally announced April 2016.
-
AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz
Authors:
Luciano Gottardi,
Marcel Bruijn,
Jan-R. Gao,
Roland den Hartog,
Richard Hijmering,
Henk Hoevers,
Pourya Khosropanah,
Piet de Korte,
Jan van der Kuur,
Mark Lindeman,
Marcel Ridder
Abstract:
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to…
▽ More
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We conclude the paper by comparing the performance of a $4 \cdot 10^{-19} W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
△ Less
Submitted 9 April, 2016;
originally announced April 2016.
-
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Marcel Bruijn,
Jan-R. Gao,
Roland den Hartog,
Richard Hijmering,
Henk Hoevers,
Pourya Khosropanah,
Alex Kozorezov,
Jan van der Kuur,
Anton van der Linden,
Marcel Ridder
Abstract:
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based…
▽ More
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier and high- Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.
△ Less
Submitted 3 April, 2016;
originally announced April 2016.
-
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Didier Barret,
Marcel P. Bruijn,
Roland H. den Hartog,
Jan-Willem den Herder,
Henk F. C. Hoevers,
Mikko Kiviranta,
Jan van der Kuur,
Anton J. van der Linden,
Brian D. Jackson,
Madu Jambunathan,
Marcel L. Ridder
Abstract:
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with diff…
▽ More
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.
△ Less
Submitted 2 April, 2016;
originally announced April 2016.
-
Optical performance of an ultra-sensitive horn-coupled transition-edge-sensor bolometer with hemispherical backshort in the far infrared
Authors:
Michael D. Audley,
Gert de Lange,
Jian-Rong Gao,
Pourya Khosropanah,
Richard Hijmering,
Marcel Ridder,
Philip D. Mauskopf,
Dmitry Morozov,
Neil A. Trappe,
Stephen Doherty
Abstract:
The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$μ\rm m$ band where radiation is coupled to the detectors with a few-mode…
▽ More
The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$μ\rm m$ band where radiation is coupled to the detectors with a few-moded conical feedhorn and a hemispherical backshort. We show that these detectors have an optical efficiency of 60% (the ratio of the power detected by the TES bolometer to the total power propagating through the feedhorn). We find that the measured optical efficiency can be understood in terms of the modes propagating through the feedhorn with the aid of a spatial mode-filtering technique.
△ Less
Submitted 25 March, 2016;
originally announced March 2016.