-
Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroyuki Uchida,
Kouichi Hagino,
Shogo Benjamin Kobayashi,
Hiromasa Suzuki,
Tessei Yoshida,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Kumiko Nobukawa,
Tomokage Yoneyama,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi,
Keisuke Tamura,
Rozenn Boissay-Malaquin
, et al. (30 additional authors not shown)
Abstract:
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an…
▽ More
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
Jin Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Mariko Saito,
Kumiko K. Nobukawa,
Takaaki Tanaka,
Hiroyuki Uchida,
Kiyoshi Hayashida,
Hironori Matsumoto,
Hirofumi Noda,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hiroshi Tomida,
Hikari Kashimura,
Hiroshi Nakajima
, et al. (16 additional authors not shown)
Abstract:
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the…
▽ More
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.
△ Less
Submitted 15 September, 2020; v1 submitted 14 September, 2020;
originally announced September 2020.
-
Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM
Authors:
Hiroyuki Uchida,
Takaaki Tanaka,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hirofumi Noda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Hiroshi Nakajima,
Mariko Saito,
Kumiko K. Nobukawa,
Hiroshi Tomida,
Yoshiaki Kanemaru,
Jin Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Hikari Kashimura
, et al. (21 additional authors not shown)
Abstract:
We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopte…
▽ More
We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.
△ Less
Submitted 16 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.