-
Gas selection for Xe-based LCP-GEM detectors onboard the CubeSat X-ray observatory NinjaSat
Authors:
T. Takeda,
T. Tamagawa,
T. Enoto,
T. Kitaguchi,
Y. Kato,
T. Mihara,
W. Iwakiri,
M. Numazawa,
Y. Zhou,
K. Uchiyama,
Y. Yoshida,
N. Ota,
S. Hayashi,
S. Watanabe,
A. Jujo,
H. Sato,
C. P. Hu,
H. Takahashi,
H. Odaka,
T. Tamba,
K. Taniguchi
Abstract:
We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas mixture at a pressure of 1.2 atm that is sensitive to high-energy X-rays. In addition, an effective gain of over 300 is required for a single GEM so that the 2 keV…
▽ More
We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas mixture at a pressure of 1.2 atm that is sensitive to high-energy X-rays. In addition, an effective gain of over 300 is required for a single GEM so that the 2 keV X-ray signal can be sufficiently larger than the electrical noise. At first, we measured the effective gains of GEM in nine Xe-based gas mixtures (combinations of Xe, Ar, CO2, CH4, and dimethyl ether; DME) at 1.0 atm. The highest gains were obtained with Xe/Ar/DME mixtures, while relatively lower gains were obtained with Xe/Ar/CO2, Xe/Ar/CH4, and Xe+quencher mixtures. Based on these results, we selected the Xe/Ar/DME (75%/24%/1%) mixture at 1.2 atm as the sealed gas for GMC. Then we investigated the dependence of an effective gain on the electric fields in the drift and induction gaps ranging from 100-650 V cm$^{-1}$ and 500-5000 V cm$^{-1}$, respectively, in the selected gas mixture. The effective gain weakly depended on the drift field while it was almost linearly proportional to the induction field: 2.4 times higher at 5000 V cm$^{-1}$ than at 1000 V cm$^{-1}$. With the optimal induction and drift fields, the flight model GMC achieves an effective gain of 460 with an applied GEM voltage of 590 V.
△ Less
Submitted 19 June, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
A strong X-ray polarization signal from the magnetar 1RXS J170849.0-400910
Authors:
Silvia Zane,
Roberto Taverna,
Denis Gonzalez Caniulef,
Fabio Muleri,
Roberto Turolla,
Jeremy Heyl,
Keisuke Uchiyama,
Mason Ng,
Toru Tamagawa,
Ilaria Caiazzo,
Niccolo' Di Lalla,
Herman L. Marshall,
Matteo Bachetti,
Fabio La Monaca,
Ephraim Gau,
Alessandro Di Marco,
Luca Baldini,
Michela Negro,
Nicola Omodei,
John Rankin,
Giorgio Matt,
George G. Pavlov,
Takao Kitaguchi,
Henric Krawczynski,
Fabian Kislat
, et al. (77 additional authors not shown)
Abstract:
Magnetars are the most strongly magnetized neutron stars, and one of the most promising targets for X-ray polarimetric measurements. We present here the first Imaging X-ray Polarimetry Explorer (IXPE) observation of the magnetar 1RXS J170849.0-400910, jointly analysed with a new Swift observation and archival NICER data. The total (energy and phase integrated) emission in the 2-8 keV energy range…
▽ More
Magnetars are the most strongly magnetized neutron stars, and one of the most promising targets for X-ray polarimetric measurements. We present here the first Imaging X-ray Polarimetry Explorer (IXPE) observation of the magnetar 1RXS J170849.0-400910, jointly analysed with a new Swift observation and archival NICER data. The total (energy and phase integrated) emission in the 2-8 keV energy range is linerarly polarized, at a ~35% level. The phase-averaged polarization signal shows a marked increase with energy, ranging from ~20% at 2-3 keV up to ~80% at 6-8 keV, while the polarization angle remain constant. This indicates that radiation is mostly polarized in a single direction. The spectrum is well reproduced by a combination of either two thermal (blackbody) components or a blackbody and a power law. Both the polarization degree and angle also show a variation with the spin phase, and the former is almost anti-correlated with the source counts in the 2-8 keV and 2-4 keV bands. We discuss the possible implications and interpretations, based on a joint analysis of the spectral, polarization and pulsation properties of the source. A scenario in which the surface temperature is not homogeneous, with a hotter cap covered by a gaseous atmosphere and a warmer region in a condensed state, provides a satisfactory description of both the phase- and energy-dependent spectro-polarimetric data. The (comparatively) small size of the two emitting regions, required to explain the observed pulsations, does not allow to reach a robust conclusion about the presence of vacuum birefringence effects.
△ Less
Submitted 30 January, 2023;
originally announced January 2023.
-
Polarized x-rays from a magnetar
Authors:
Roberto Taverna,
Roberto Turolla,
Fabio Muleri,
Jeremy Heyl,
Silvia Zane,
Luca Baldini,
Denis González Caniulef,
Matteo Bachetti,
John Rankin,
Ilaria Caiazzo,
Niccolò Di Lalla,
Victor Doroshenko,
Manel Errando,
Ephraim Gau,
Demet Kırmızıbayrak,
Henric Krawczynski,
Michela Negro,
Mason Ng,
Nicola Omodei,
Toru Tamagawa,
Keisuke Uchiyama,
Martin C. Weisskopf,
Ivan Agudo,
Lucio A. Antonelli,
Wayne H. Baumgartner
, et al. (71 additional authors not shown)
Abstract:
We report on the first detection of linearly polarized x-ray emission from an ultra-magnetized neutron star with the Imaging X-ray Polarimetry Explorer (IXPE). The IXPE 35 observations of the anomalous x-ray pulsar 4U 0142+61 reveal a linear polarization degree of $(12\pm 1)\%$ throughout the IXPE 2--8 keV band. We detect a substantial variation of the polarization with energy: the degree is…
▽ More
We report on the first detection of linearly polarized x-ray emission from an ultra-magnetized neutron star with the Imaging X-ray Polarimetry Explorer (IXPE). The IXPE 35 observations of the anomalous x-ray pulsar 4U 0142+61 reveal a linear polarization degree of $(12\pm 1)\%$ throughout the IXPE 2--8 keV band. We detect a substantial variation of the polarization with energy: the degree is $(14\pm 1)\%$ at 2--4 keV and $(41\pm 7)\%$ at 5.5--8 keV, while it drops below the instrumental sensitivity around 4--5 keV, where the polarization angle swings by $\sim 90^\circ$. The IXPE observations give us completely new information about the properties of the neutron star surface and magnetosphere and lend further support to the presence of the quantum mechanical effect of vacuum birefringence.
△ Less
Submitted 18 May, 2022;
originally announced May 2022.
-
Design, Construction, and Test of the Gas Pixel Detectors for the IXPE Mission
Authors:
L. Baldini,
M. Barbanera,
R. Bellazzini,
R. Bonino,
F. Borotto,
A. Brez,
C. Caporale,
C. Cardelli,
S. Castellano,
M. Ceccanti,
S. Citraro,
N. Di Lalla,
L. Latronico,
L. Lucchesi,
C. Magazzù,
G. Magazzù,
S. Maldera,
A. Manfreda,
M. Marengo,
A. Marrocchesi,
P. Mereu,
M. Minuti,
F. Mosti,
H. Nasimi,
A. Nuti
, et al. (69 additional authors not shown)
Abstract:
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collectin…
▽ More
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis -- particularly as far as the response to unpolarized radiation and the stability in time are concerned.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Multiplexing lobster-eye optics: a concept for wide-field X-ray monitoring
Authors:
Toru Tamagawa,
Keisuke Uchiyama,
Ryota Otsubo,
Tatsuya Yuasa,
Yuanhui Zhou,
Tatehiro Mihara,
Yuichiro Ezoe,
Masaki Numazawa,
Daiki Ishi,
Aoto Fukushima,
Hikaru Suzuki,
Tomoki Uchino,
Sae Sakuta,
Kumi Ishikawa,
Teruaki Enoto,
Takanori Sakamoto
Abstract:
We propose a concept of multiplexing lobster-eye (MuLE) optics to achieve significant reductions in the number of focal plane imagers in lobster-eye (LE) wide-field X-ray monitors. In the MuLE configuration, an LE mirror is divided into several segments and the X-rays reflected on each of these segments are focused on a single image sensor in a multiplexed configuration. If each LE segment assumes…
▽ More
We propose a concept of multiplexing lobster-eye (MuLE) optics to achieve significant reductions in the number of focal plane imagers in lobster-eye (LE) wide-field X-ray monitors. In the MuLE configuration, an LE mirror is divided into several segments and the X-rays reflected on each of these segments are focused on a single image sensor in a multiplexed configuration. If each LE segment assumes a different rotation angle, the azimuthal rotation angle of a cross-like image reconstructed from a point source by the LE optics identifies the specific segment that focuses the X-rays on the imager. With a focal length of 30 cm and LE segments with areas of 10 x 10 cm^2, ~1 sr of the sky can be covered with 36 LE segments and only four imagers (with total areas of 10 x 10 cm^2). A ray tracing simulation was performed to evaluate the nine-segment MuLE configuration. The simulation showed that the flux (0.5 to 2 keV) associated with the 5-sigma detection limit was ~2 x 10^-10 erg cm^-2 s^-1 (10 mCrab) for a transient with a duration of 100 s. The simulation also showed that the direction of the transient for flux in the range of 14 to 17 mCrab at 0.6 keV was determined correctly with 99.7% confidence limit. We conclude that the MuLE configuration can become an effective on-board device for small satellites for future X-ray wide-field transient monitoring.
△ Less
Submitted 4 July, 2020;
originally announced July 2020.