-
Magnetic Impurity Effects on Ferromagnetic Fluctuations in Heavily Overdoped (Bi,Pb)$_2$Sr$_2$Cu$_{1-y}$Fe$_y$O$_{6+δ}$ Cuprates
Authors:
Y. Komiyama,
S. Onishi,
M. Harada,
H. Kuwahara,
H. Kuroe,
K. Kurashima,
T. Kawamata,
Y. Koike,
I. Watanabe,
T. Adachi
Abstract:
We investigated Fe-substitution effects on ferromagnetic fluctuations in the superconducting overdoped and non-superconducting heavily overdoped regimes of the Bi-2201 cuprates by the magnetization and electrical-resistivity measurements. It was found that the spin-glass state was induced at low temperatures by the Fe substitution. The Curie constant and the effective Bohr magneton, estimated from…
▽ More
We investigated Fe-substitution effects on ferromagnetic fluctuations in the superconducting overdoped and non-superconducting heavily overdoped regimes of the Bi-2201 cuprates by the magnetization and electrical-resistivity measurements. It was found that the spin-glass state was induced at low temperatures by the Fe substitution. The Curie constant and the effective Bohr magneton, estimated from the magnetic susceptibility, as well as the dimensionality of the ferromagnetic fluctuations from the resistivity, suggest the enhancement of the ferromagnetic fluctuations owing to the Fe substitution. A ferromagnetic spin-cluster model is proposed in the heavily overdoped regime of Bi-2201, while an antiferromagnetic spin-cluster model has been proposed in the overdoped regime of Bi-2201 [Hiraka et al., Phys. Rev. B 81, 144501 (2010)].
△ Less
Submitted 6 July, 2021; v1 submitted 29 May, 2021;
originally announced May 2021.
-
Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor
Authors:
The Dang Vu,
Hiroaki Shishido,
Kazuya Aizawa,
Kenji M. Kojima,
Tomio Koyama,
Kenichi Oikawa,
Masahide Harada,
Takayuki Oku,
Kazuhiko Soyama,
Shigeyuki Miyajima,
Mutsuo Hidaka,
Soh Y. Suzuki,
Manobu M. Tanakai,
Alex Malins,
Masahiko Machida,
Shuichi Kawamata,
Takekazu Ishida
Abstract:
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission and scanning electron microscope (SEM) images of Gd islands with sizes between 15 and 130 micrometer which were thermally-sprayed onto a Si substrate. Neutron tr…
▽ More
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission and scanning electron microscope (SEM) images of Gd islands with sizes between 15 and 130 micrometer which were thermally-sprayed onto a Si substrate. Neutron transmission images could be used to identify tiny voids in a thermally-sprayed continuous Gd2O3 film on a Si substrate which could not be seen in SEM images. We also found that neutron transmission images revealed pattern formations, mosaic features and co-existing dendritic phases in Wood's metal samples with constituent elements Bi, Pb, Sn and Cd. These results demonstrate the merits of the current-biased kinetic inductance detector (CB-KID) system for practical studies in materials science. Moreover, we found that operating the detector at a more optimal temperature (7.9 K) appreciably improved the effective detection efficiency when compared to previous studies conducted at 4 K. This is because the effective size of hot-spots in the superconducting meanderline planes increases with temperature, which makes particle detections more likely.
△ Less
Submitted 8 May, 2021;
originally announced May 2021.
-
Magnetic phase diagram of Sr$_{1-x}$Ca$_x$Co$_2$P$_2$
Authors:
J. Sugiyama,
H. Nozaki,
I. Umegaki,
M. Harada,
Y. Higuchi,
E. J. Ansaldo,
J. H. Brewer,
M. Imai,
C. Michioka,
K. Yoshimura,
M Månsson
Abstract:
In order to study the phase diagram from a microscopic viewpoint, we have measured wTF- and ZF-$μ^+$SR spectra for the Sr$_{1-x}$Ca$_x$Co$_2$P$_2$ powder samples with $x=0$, 0.2, 0.4, 0.5, 0.6, 0.8, and 1. Due to a characteristic time window and spatial resolution of $μ^+$SR, the obtained phase diagram was found to be rather different from that determined by magnetization measurements. That is, as…
▽ More
In order to study the phase diagram from a microscopic viewpoint, we have measured wTF- and ZF-$μ^+$SR spectra for the Sr$_{1-x}$Ca$_x$Co$_2$P$_2$ powder samples with $x=0$, 0.2, 0.4, 0.5, 0.6, 0.8, and 1. Due to a characteristic time window and spatial resolution of $μ^+$SR, the obtained phase diagram was found to be rather different from that determined by magnetization measurements. That is, as $x$ increases from 0, a Pauli-paramagnetic phase is observed even at the lowest $T$ measured (1.8~K) until $x=0.4$, then, a spin-glass like phase appears at $0.5\leq x\leq0.6$, and then, a phase with wide field distribution probably due to incommensurate AF order is detected for $x=0.8$, and finally, a commensurate $A$-type AF ordered phase (for $x=1$) is stabilized below $T_{\rm N}\sim80~$K. Such change is most likely reasonable and connected to the shrink of the $c$-axis length with $x$, which naturally enhances the magnetic interaction between the two adjacent Co planes.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
Neutron imaging detector based on the muPIC micro-pixel chamber
Authors:
J. D. Parker,
K. Hattori,
H. Fujioka,
M. Harada,
S. Iwaki,
S. Kabuki,
Y. Kishimoto,
H. Kubo,
S. Kurosawa,
K. Miuchi,
T. Nagae,
H. Nishimura,
T. Oku,
T. Sawano,
T. Shinohara,
J. Suzuki,
A. Takada,
T. Tanimori,
K. Ueno
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measur…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.