(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–3 of 3 results for author: Sakar, B

Searching in archive cond-mat. Search in all archives.
.
  1. A Ti/Pt/Co multilayer stack for transfer function based magnetic force microscopy calibrations

    Authors: Baha Sakar, Sibylle Sievers, Alexander Fernandez Scarioni, Felipe Garcia-Sanchez, Ilker Oztoprak, Hans Werner Schumacher, Osman Ozturk

    Abstract: Magnetic force microscopy is a widespread technique for imaging magnetic structures with a resolution of some 10 nanometers. MFM can be calibrated to obtain quantitative spatially resolved magnetization data in units of A/m by determining the calibrated point spread function of the instrument, its instrument calibration function (ICF), from a measurement of a well-known reference sample. Beyond qu… ▽ More

    Submitted 24 January, 2022; originally announced January 2022.

    Comments: 24 page 12 Picture

  2. arXiv:2105.09355  [pdf

    cond-mat.mes-hall physics.app-ph

    Structural and Morphological Effect of Ti underlayer on Pt/Co/Pt Magnetic Ultra-Thin Film

    Authors: Melek Türksoy Öcal, Baha Sakar, İlker Öztoprak, Zoltan Balogh-Michels, Antonia Neels, Osman Öztürk

    Abstract: Pt(xÅ)/Co(5Å)/Pt(10Å) trilayer films were deposited on naturally oxidized Si(111) substrate to investigate Ti underlayer effect on PMA. A small amount of Ti underlayer promoted the magnetic anisotropy to a perpendicular direction for x=8Å and 10Å. Both GI XRD and STM results showed that the Ti underlayer manipulated the growth of trilayer film. The Pt particles preferably grow the neighborhood of… ▽ More

    Submitted 19 May, 2021; originally announced May 2021.

  3. Quantum calibrated magnetic force microscopy

    Authors: Baha Sakar, Yan Liu, Sibylle Sievers, Volker Neu, Johannes Lang, Christian Osterkamp, Matthew L. Markham, Osman Öztürk, Fedor Jelezko, Hans W. Schumacher

    Abstract: We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray field distribution of the MFM tip using a single nitrogen vacancy (NV) center in diamond. From the measured stray field distribution and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images to quantum calibrated stray field m… ▽ More

    Submitted 6 December, 2021; v1 submitted 25 March, 2021; originally announced March 2021.