-
Precision Calorimetry at HL-LHC: Upgrade of the CMS Electromagnetic Calorimeter
Authors:
Stefano Argiro
Abstract:
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges. The four to five-fold increase of the number of interactions per bunch crossing will require superior time resolution and noise rejection capabilities. For these…
▽ More
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges. The four to five-fold increase of the number of interactions per bunch crossing will require superior time resolution and noise rejection capabilities. For these reasons the electronics readout has been completely redesigned. A dual gain trans-impedance amplifier and an ASIC providing two 160 MHz ADC channels, gain selection, and data compression will be used in the new readout electronics. The trigger decision will be moved off-detector and will be performed by powerful and flexible FPGA processors, allowing for more sophisticated trigger algorithms to be applied. The upgraded ECAL will be capable of high-precision energy measurements throughout HL-LHC and will greatly improve the time resolution for photons and electrons above 10 GeV.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Comparison of Fast Amplifiers for Diamond Detectors
Authors:
M. Osipenko,
S. Minutoli,
P. Musico,
M. Ripani,
B. Caiffi,
A. Balbi,
G. Ottonello,
S. Argirò,
S. Beolè,
N. Amapane,
M. Masera,
G. Mila
Abstract:
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a nu…
▽ More
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a number of commercial amplifiers designed for diamond detector readout to identify the best solution for a particular application. This application required a deposited energy threshold below 100 keV and timing resolution of the order of 200 ps at 200 keV. None of tested amplifiers satisfies these requirements. The best solution to such application found to be the Cividec C6 amplifier, which allows 100 keV minimal threshold, but its coincidence timing resolution at 200 keV is as large as 1.2 ns.
△ Less
Submitted 3 October, 2013;
originally announced October 2013.
-
Bottom Production, Spectroscopy and Lifetimes
Authors:
Stefano Argirò
Abstract:
In this contribution, I give a brief overview of the latest results related to the production, spectroscopy and lifetimes of bottom and charm hadrons. Several interesting experimental results were presented in this field in 2012. The focus will be on the findings of experiments performed at hadron colliders, since the LHC is taking up most of the stage this year, with a brief mention about electro…
▽ More
In this contribution, I give a brief overview of the latest results related to the production, spectroscopy and lifetimes of bottom and charm hadrons. Several interesting experimental results were presented in this field in 2012. The focus will be on the findings of experiments performed at hadron colliders, since the LHC is taking up most of the stage this year, with a brief mention about electron-proton collider results.
△ Less
Submitted 18 February, 2013; v1 submitted 2 January, 2013;
originally announced January 2013.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.