-
Rydberg-atom-based single-photon detection for haloscope axion searches
Authors:
Eleanor Graham,
Sumita Ghosh,
Yuqi Zhu,
Xiran Bai,
Sidney B. Cahn,
Elsa Durcan,
Michael J. Jewell,
Danielle H. Speller,
Sabrina M. Zacarias,
Laura T. Zhou,
Reina H. Maruyama
Abstract:
We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 $μ$eV and 200 $μ$eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements…
▽ More
We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 $μ$eV and 200 $μ$eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements up to a factor of $10^4$ over traditional linear amplifier readout, and is compatible with many different haloscope cavities. We identify multiple haloscope designs that could use our Rydberg-atom-based single-photon detector to search for QCD axions with masses above 40 $μ$eV (10 GHz), currently a minimally explored parameter space.
△ Less
Submitted 10 November, 2023; v1 submitted 23 October, 2023;
originally announced October 2023.
-
New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver
Authors:
HAYSTAC Collaboration,
M. J. Jewell,
A. F. Leder,
K. M. Backes,
Xiran Bai,
K. van Bibber,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Maryam H. Esmat,
Sumita Ghosh,
Eleanor Graham,
Gene C. Hilton,
H. Jackson,
Claire Laffan,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
E. P. Ruddy,
M. Simanovskaia,
Sukhman Singh
, et al. (4 additional authors not shown)
Abstract:
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr…
▽ More
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.
△ Less
Submitted 26 January, 2023; v1 submitted 23 January, 2023;
originally announced January 2023.
-
The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector
Authors:
E. Bodnia,
E. P. Bernard,
A. Biekert,
E. M. Boulton,
S. B. Cahn,
N. Destefano,
B. N. V. Edwards,
M. Gai,
M. Horn,
N. A. Larsen,
Q. Riffard,
B. Tennyson,
V. Velan,
C. Wahl,
D. N. McKinsey
Abstract:
Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events a…
▽ More
Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.
△ Less
Submitted 16 December, 2021; v1 submitted 10 January, 2021;
originally announced January 2021.
-
A quantum-enhanced search for dark matter axions
Authors:
K. M. Backes,
D. A. Palken,
S. Al Kenany,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Gene C. Hilton,
Sumita Ghosh,
H. Jackson,
S. K. Lamoreaux,
A. F. Leder,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
N. M. Rapidis,
M. Simanovskaia,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
Leila R. Vale,
E. C. van Assendelft,
K. van Bibber,
H. Wang
Abstract:
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we do…
▽ More
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.
△ Less
Submitted 4 August, 2020;
originally announced August 2020.
-
An improved analysis framework for axion dark matter searches
Authors:
D. A. Palken,
B. M. Brubaker,
M. Malnou,
S. Al Kenany,
K. M. Backes,
S. B. Cahn,
Y. V. Gurevich,
S. K. Lamoreaux,
S. M. Lewis,
R. H. Maruyama,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
K. van Bibber,
L. Zhong,
K. W. Lehnert
Abstract:
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f…
▽ More
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
△ Less
Submitted 28 July, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Results from phase 1 of the HAYSTAC microwave cavity axion experiment
Authors:
L. Zhong,
S. Al Kenany,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
D. H. Speller,
I. Urdinaran,
K. A. van Bibber
Abstract:
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range…
▽ More
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Position Reconstruction in LUX
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional fo…
▽ More
The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including ${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H ($β^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an $(x, y)$ position uncertainty of $σ$= 0.82 cm for events of only 200 electroluminescence photons and $σ$ = 0.17 cm for 4,000 electroluminescence photons. Such signals are associated with electron recoils of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.
△ Less
Submitted 12 March, 2018; v1 submitted 7 October, 2017;
originally announced October 2017.
-
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea…
▽ More
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
△ Less
Submitted 3 September, 2017;
originally announced September 2017.
-
3D Modeling of Electric Fields in the LUX Detector
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's a…
▽ More
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, generating an electrostatic radially-inward force on electrons on their way upward to the liquid surface. To map this behavior, 3D electric field maps of the detector's active volume were built on a monthly basis. This was done by fitting a model built in COMSOL Multiphysics to the uniformly distributed calibration data that were collected on a regular basis. The modeled average PTFE charge density increased over the course of the exposure from -3.6 to $-5.5~μ$C/m$^2$. From our studies, we deduce that the electric field magnitude varied while the mean value of the field of $\sim200$~V/cm remained constant throughout the exposure. As a result of this work the varying electric fields and their impact on event reconstruction and discrimination were successfully modeled.
△ Less
Submitted 27 November, 2017; v1 submitted 31 August, 2017;
originally announced September 2017.
-
First results from a microwave cavity axion search at 24 micro-eV
Authors:
B. M. Brubaker,
L. Zhong,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. Simanovskaia,
J. R. Root,
S. M. Lewis,
S. Al Kenany,
K. M. Backes,
I. Urdinaran,
N. M. Rapidis,
T. M. Shokair,
K. A. van Bibber,
D. A. Palken,
M. Malnou,
W. F. Kindel,
M. A. Anil,
K. W. Lehnert,
G. Carosi
Abstract:
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde…
▽ More
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.
△ Less
Submitted 9 February, 2017; v1 submitted 8 October, 2016;
originally announced October 2016.
-
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additiona…
▽ More
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with $^3$H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Results from a search for dark matter in the complete LUX exposure
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high…
▽ More
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
△ Less
Submitted 13 January, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison
, et al. (82 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T…
▽ More
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
△ Less
Submitted 26 October, 2016; v1 submitted 18 August, 2016;
originally announced August 2016.
-
Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of…
▽ More
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n~=~9.4~\times~10^{-41}~\text{cm}^2$ ($σ_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
△ Less
Submitted 16 May, 2016; v1 submitted 10 February, 2016;
originally announced February 2016.
-
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background…
▽ More
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $β$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
△ Less
Submitted 16 May, 2016; v1 submitted 10 December, 2015;
originally announced December 2015.
-
Tritium calibration of the LUX dark matter experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (76 additional authors not shown)
Abstract:
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu…
▽ More
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
△ Less
Submitted 5 May, 2016; v1 submitted 9 December, 2015;
originally announced December 2015.
-
Future Directions in the Microwave Cavity Search for Dark Matter Axions
Authors:
T. M. Shokair,
J. Root,
K. A. Van Bibber,
B. Brubaker,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. A. Anil,
K. W. Lehnert,
B. K. Mitchell,
A. Reed,
G. Carosi
Abstract:
The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrate…
▽ More
The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrated sensitivity to plausible axion models, and upgrades in progress should achieve the sensitivity required for a definitive search, at least for low mass axions. However, a comprehensive strategy for scanning the entire mass range, from 1-1000 $μ$eV, will require significant technological advances to maintain the needed sensitivity at higher frequencies. Such advances could include sub-quantum-limited amplifiers based on squeezed vacuum states, bolometers, and/or superconducting microwave cavities. The Axion Dark Matter eXperiment at High Frequencies (ADMX-HF) represents both a pathfinder for first data in the 20-100 $μ$eV range ($\sim$5-25 GHz), and an innovation test-bed for these concepts.
△ Less
Submitted 14 May, 2014;
originally announced May 2014.
-
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Authors:
M. Szydagis,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci
, et al. (55 additional authors not shown)
Abstract:
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keV…
▽ More
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
△ Less
Submitted 25 February, 2014; v1 submitted 15 February, 2014;
originally announced February 2014.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.
-
The Large Underground Xenon (LUX) Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
C. Camp,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
A. Chiller,
C. Chiller,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
E. Dahl,
S. Dazeley,
L. de Viveiros,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz
, et al. (69 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100…
▽ More
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100 kg/month in the inner 100-kg fiducial volume (FV) of the 370-kg detector. The overall background goals are set to have $<$1 background events characterized as possible WIMPs in the FV in 300 days of running.
This paper describes the design and construction of the LUX detector.
△ Less
Submitted 21 November, 2012; v1 submitted 15 November, 2012;
originally announced November 2012.
-
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
J. J. Chapman,
T. Coffey,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
M. Gilchriese,
C. Hall,
M. Hanhardt,
M. Ihm,
R. G. Jacobsen,
L. Kastens
, et al. (42 additional authors not shown)
Abstract:
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i…
▽ More
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 22 February, 2013; v1 submitted 16 October, 2012;
originally announced October 2012.
-
An Ultra-Low Background PMT for Liquid Xenon Detectors
Authors:
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Coffey,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (42 additional authors not shown)
Abstract:
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det…
▽ More
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
△ Less
Submitted 24 June, 2013; v1 submitted 10 May, 2012;
originally announced May 2012.
-
Radio-assay of Titanium samples for the LUX Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook
, et al. (41 additional authors not shown)
Abstract:
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample w…
▽ More
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample with the lowest total long-lived activity was measured to contain <0.25 mBq/kg of U-238, <0.2 mBq/kg of Th-232, and <1.2 mBq/kg of K-40. Measurements of several samples also indicated the presence of short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon initiated (n,p) reactions.
△ Less
Submitted 12 February, 2012; v1 submitted 6 December, 2011;
originally announced December 2011.
-
LUXSim: A Component-Centric Approach to Low-Background Simulations
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. de Viveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (38 additional authors not shown)
Abstract:
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo…
▽ More
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.
* Corresponding author, kareem@llnl.gov
△ Less
Submitted 8 November, 2011;
originally announced November 2011.
-
Scintillation and charge extraction from the tracks of energetic electrons in superfluid helium-4
Authors:
W. Guo,
M. Dufault,
S. B. Cahn,
J. A. Nikkel,
Y. Shin,
D. N. McKinsey
Abstract:
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied…
▽ More
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied field depends on the separation distance between the electrons and the ions. We report the determination of the mean electron-ion separation distance for charge pairs produced along the tracks of beta particles in superfluid helium at 1.5 K by studying the quenching of the scintillation light under applied electric fields. Knowledge of this mean separation parameter will aid in the design of particle detectors that use superfluid helium as a target material.
△ Less
Submitted 26 September, 2011;
originally announced September 2011.
-
Calibration of a Liquid Xenon Detector with Kr-83m
Authors:
L. W. Kastens,
S. B. Cahn,
A. Manzur,
D. N. McKinsey
Abstract:
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of K…
▽ More
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of Kr-83m were both observed. This calibration source will allow the characterization of the scintillation and ionization response of noble liquid detectors at low energies, highly valuable for the search for WIMP dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both to understand purification in noble liquid-based particle detectors, as well as for studies of classical and quantum turbulence in superfluid helium.
△ Less
Submitted 11 December, 2009; v1 submitted 12 May, 2009;
originally announced May 2009.