-
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (168 additional authors not shown)
Abstract:
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b…
▽ More
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).
△ Less
Submitted 22 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (166 additional authors not shown)
Abstract:
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable…
▽ More
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.
△ Less
Submitted 4 October, 2023; v1 submitted 11 August, 2023;
originally announced August 2023.
-
The fast non-ferric kicker system for the Muon $g-2$ Experiment at Fermilab
Authors:
A. P. Schreckenberger,
D. Allspach,
D. Barak,
J. Bohn,
C. Bradford,
D. Cauz,
S. P. Chang,
A. Chapelain,
S. Chappa,
S. Charity,
R. Chislett,
J. Esquivel,
C. Ferrari,
A. Fioretti,
C. Gabbanini,
M. D. Galati,
L. Gibbons,
J. L. Holzbauer,
M. Incagli,
C. Jensen,
J. Kaspar,
D. Kawall,
A. Keshavarzi,
D. S. Kessler,
B. Kiburg
, et al. (17 additional authors not shown)
Abstract:
We describe the installation, commissioning, and characterization of the new injection kicker system in the Muon $g-2$ Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system…
▽ More
We describe the installation, commissioning, and characterization of the new injection kicker system in the Muon $g-2$ Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon $g-2$'s predecessor experiment, and we present those details in this manuscript.
△ Less
Submitted 3 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Authors:
B. Abi,
T. Albahri,
S. Al-Kilani,
D. Allspach,
L. P. Alonzi,
A. Anastasi,
A. Anisenkov,
F. Azfar,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
A. Basti,
F. Bedeschi,
A. Behnke,
M. Berz,
M. Bhattacharya,
H. P. Binney,
R. Bjorkquist,
P. Bloom,
J. Bono,
E. Bottalico
, et al. (212 additional authors not shown)
Abstract:
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in…
▽ More
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment
Authors:
T. Albahri,
A. Anastasi,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
A. Basti,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain
, et al. (153 additional authors not shown)
Abstract:
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muo…
▽ More
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (148 additional authors not shown)
Abstract:
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrat…
▽ More
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
△ Less
Submitted 17 June, 2022; v1 submitted 7 April, 2021;
originally announced April 2021.
-
The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab
Authors:
A. Anastasi,
A. Basti,
F. Bedeschi,
A. Boiano,
E. Bottalico,
G. Cantatore,
D. Cauz,
A. T. Chapelain,
G. Corradi,
S. Dabagov,
S. Di Falco,
P. Di Meo,
G. Di Sciascio,
R. Di Stefano,
S. Donati,
A. Driutti,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
L. K. Gibbons,
A. Gioiosa,
P. Girotti,
D. Hampai,
J. B. Hempstead
, et al. (19 additional authors not shown)
Abstract:
The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of t…
▽ More
The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.
△ Less
Submitted 28 November, 2019; v1 submitted 19 June, 2019;
originally announced June 2019.
-
Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data
Authors:
K. S. Khaw,
M. Bartolini,
H. Binney,
R. Bjorkquist,
A. Chapelain,
A. Driutti,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
S. Ganguly,
L. K. Gibbons,
A. Gioiosa,
K. Giovanetti,
W. P. Gohn,
T. P. Gorringe,
J. B. Hempstead,
D. W. Hertzog,
M. Iacovacci,
J. Kaspar,
A. Kuchibhotla,
S. Leo,
A. Lusiani,
S. Mastroianni,
G. Pauletta
, et al. (9 additional authors not shown)
Abstract:
A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS dat…
▽ More
A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.
△ Less
Submitted 22 February, 2020; v1 submitted 10 May, 2019;
originally announced May 2019.
-
The Muon g-2 experiment at Fermilab
Authors:
Antoine Chapelain
Abstract:
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment $a_μ$ . This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing…
▽ More
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment $a_μ$ . This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.
△ Less
Submitted 10 January, 2017;
originally announced January 2017.
-
Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications
Authors:
J. Kaspar,
A. T. Fienberg,
D. W. Hertzog,
M. A. Huehn,
P. Kammel,
K. S. Khaw,
D. A. Peterson,
M. W. Smith,
T. D. Van Wechel,
A. Chapelain,
L. K. Gibbons,
D. A. Sweigart,
C. Ferrari,
A. Fioretti,
C. Gabbanini,
G. Venanzoni,
M. Iacovacci,
S. Mastroianni,
K. Giovanetti,
W. Gohn,
T. Gorringe,
D. Pocanic
Abstract:
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storag…
▽ More
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. The performance is documented in a series of bench and beam tests.
△ Less
Submitted 22 December, 2016; v1 submitted 9 November, 2016;
originally announced November 2016.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Charge asymmetry of top quark-antiquark pairs
Authors:
Antoine Chapelain
Abstract:
In this note we present the charge asymmetry measurements of top quark-antiquark pairs at hadron colliders. We will focus on the dilepton channel at ATLAS (LHC) and D0 (Tevatron).
In this note we present the charge asymmetry measurements of top quark-antiquark pairs at hadron colliders. We will focus on the dilepton channel at ATLAS (LHC) and D0 (Tevatron).
△ Less
Submitted 27 January, 2014;
originally announced January 2014.
-
Measurement of the leptonic ttbar charge asymmetry in the dilepton channel with the D0 detector
Authors:
Antoine Chapelain
Abstract:
We present the legacy measurement of the leptonic ttbar charge asymmetry in the dilepton channel with the D0 detector.
We present the legacy measurement of the leptonic ttbar charge asymmetry in the dilepton channel with the D0 detector.
△ Less
Submitted 26 November, 2013;
originally announced November 2013.
-
tt Charge asymmetry at hadron colliders
Authors:
Antoine Chapelain
Abstract:
We present the current status for the measurements of the ttbar charge asymmetry at the Tevatron and LHC colliders.
We present the current status for the measurements of the ttbar charge asymmetry at the Tevatron and LHC colliders.
△ Less
Submitted 18 October, 2013;
originally announced October 2013.