-
Search for a Non-Relativistic Boson in Two-Body Antimuon Decay
Authors:
J. I. Collar,
P. S. Cooper,
C. M. Lewis
Abstract:
We demonstrate the feasibility of probing the charged lepton flavor violating decay $μ^{+}\!\!\rightarrow \!e^{+} X^{0}$ for the presence of a slow-moving neutral boson $X^{0}$ capable of undergoing gravitational binding to large structures, and as such able to participate in some cosmological scenarios. A short exposure to surface antimuons from beamline M20 at TRIUMF generates a branching ratio…
▽ More
We demonstrate the feasibility of probing the charged lepton flavor violating decay $μ^{+}\!\!\rightarrow \!e^{+} X^{0}$ for the presence of a slow-moving neutral boson $X^{0}$ capable of undergoing gravitational binding to large structures, and as such able to participate in some cosmological scenarios. A short exposure to surface antimuons from beamline M20 at TRIUMF generates a branching ratio limit of $\lesssim 10^{-5}$. This is comparable or better than previous searches for this channel, although in a thus-far unexplored region of $X^{0}$ phase space very close to the kinematic limit of the decay. The future improved sensitivity of the method using a customized p-type point contact germanium detector is described.
△ Less
Submitted 15 August, 2023; v1 submitted 9 August, 2023;
originally announced August 2023.
-
Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers
Authors:
E. Adams,
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas,
A. García Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. Jin
, et al. (30 additional authors not shown)
Abstract:
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been dev…
▽ More
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.
△ Less
Submitted 21 January, 2023;
originally announced January 2023.
-
Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. Jin
, et al. (30 additional authors not shown)
Abstract:
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact…
▽ More
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.
△ Less
Submitted 21 April, 2022;
originally announced April 2022.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
P. Campion,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
G. Crowder,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
F. Girard
, et al. (37 additional authors not shown)
Abstract:
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th…
▽ More
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
△ Less
Submitted 2 August, 2017; v1 submitted 24 February, 2017;
originally announced February 2017.
-
Search for the rare decay $K^+\toμ^+ν\barνν$
Authors:
A. V. Artamonov,
B. Bassalleck,
B. Bhuyan,
E. W. Blackmore,
D. A. Bryman,
S. Chen,
I-H. Chiang,
I. -A. Christidi,
P. S. Cooper,
M. V. Diwan,
J. S. Frank,
T. Fujiwara,
J. Hu,
J. Ives,
A. O. Izmaylov,
D. E. Jaffe,
S. Kabe,
S. H. Kettell,
M. M. Khabibullin,
A. N. Khotjantsev,
P. Kitching,
M. Kobayashi,
T. K. Komatsubara,
A. Konaka,
Yu. G. Kudenko
, et al. (35 additional authors not shown)
Abstract:
Evidence of the $K^+\toμ^+ν\barνν$ decay was searched for using E949 experimental data with an exposure of $1.70\times 10^{12}$ stopped kaons. The data sample is dominated by the backgrond process $K^+\toμ^+ν_μγ$. An upper limit on the decay rate $Γ(K^+\toμ^+ν\barνν)< 2.4\times 10^{-6}Γ(K^+\to all)$ at 90% confidence level was set assuming the Standard Model muon spectrum. The data are presented i…
▽ More
Evidence of the $K^+\toμ^+ν\barνν$ decay was searched for using E949 experimental data with an exposure of $1.70\times 10^{12}$ stopped kaons. The data sample is dominated by the backgrond process $K^+\toμ^+ν_μγ$. An upper limit on the decay rate $Γ(K^+\toμ^+ν\barνν)< 2.4\times 10^{-6}Γ(K^+\to all)$ at 90% confidence level was set assuming the Standard Model muon spectrum. The data are presented in such a way as to allow calculation of rates for any assumed $μ^+$ spectrum.
△ Less
Submitted 1 September, 2016; v1 submitted 29 June, 2016;
originally announced June 2016.
-
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
F. Girard,
G. Giroux,
A. Grandison
, et al. (34 additional authors not shown)
Abstract:
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays…
▽ More
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
△ Less
Submitted 3 March, 2016; v1 submitted 26 October, 2015;
originally announced October 2015.
-
The transverse momentum dependence of charged kaon Bose-Einstein correlations in the SELEX experiment
Authors:
SELEX Collaboration,
G. A. Nigmatkulov,
A. K. Ponosov,
U. Akgun,
G. Alkhazov,
J. Amaro-Reyes,
A. Asratyan,
A. G. Atamantchouk,
A. S. Ayan,
M. Y. Balatz,
A. Blanco-Covarrubias,
N. F. Bondar,
P. S. Cooper,
L. J. Dauwe,
G. V. Davidenko,
U. Dersch,
A. G. Dolgolenko,
G. B. Dzyubenko,
R. Edelstein,
L. Emediato,
A. M. F. Endler,
J. Engelfried,
I. Eschrich,
C. O. Escobar,
N. Estrada
, et al. (79 additional authors not shown)
Abstract:
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlatio…
▽ More
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlation strength, $λ$, are extracted. The analysis shows a decrease of the source radii with increasing kaon transverse pair momentum for all beam types.
△ Less
Submitted 14 November, 2015; v1 submitted 18 January, 2015;
originally announced January 2015.
-
Search for heavy neutrinos in $K^+\toμ^+ν_H$ decays
Authors:
A. V. Artamonov,
B. Bassalleck,
B. Bhuyan,
E. W. Blackmore,
D. A. Bryman,
S. Chen,
I-H. Chiang,
I. -A. Christidi,
P. S. Cooper,
M. V. Diwan,
J. S. Frank,
T. Fujiwara,
J. Hu,
J. Ives,
A. O. Izmaylov,
D. E. Jaffe,
S. Kabe,
S. H. Kettell,
M. M. Khabibullin,
A. N. Khotjantsev,
P. Kitching,
M. Kobayashi,
T. K. Komatsubara,
A. Konaka,
Yu. G. Kudenko
, et al. (35 additional authors not shown)
Abstract:
Evidence of a heavy neutrino, $ν_H$, in the $K^+\toμ^+ν_H$ decays was sought using the E949 experimental data with an exposure of $1.70\times 10^{12}$ stopped kaons. With the major background from the radiative $K^+\toμ^+ν_μγ$ decay understood and suppressed, upper limits (90% C.L.) on the neutrino mixing matrix element between muon and heavy neutrino, $|U_{μH}|^2$, were set at the level of…
▽ More
Evidence of a heavy neutrino, $ν_H$, in the $K^+\toμ^+ν_H$ decays was sought using the E949 experimental data with an exposure of $1.70\times 10^{12}$ stopped kaons. With the major background from the radiative $K^+\toμ^+ν_μγ$ decay understood and suppressed, upper limits (90% C.L.) on the neutrino mixing matrix element between muon and heavy neutrino, $|U_{μH}|^2$, were set at the level of $10^{-7}$ to $10^{-9}$ for the heavy neutrino mass region 175 to 300 MeV/$c^2$.
△ Less
Submitted 10 February, 2015; v1 submitted 14 November, 2014;
originally announced November 2014.
-
Charged Lepton Flavor Violation: An Experimenter's Guide
Authors:
Robert H. Bernstein,
Peter S. Cooper
Abstract:
Charged lepton flavor violation (CLFV) is a clear signal of new physics; it directly addresses the physics of flavor and of generations. The search for CLFV has continued from the early 1940's, when the muon was identified as a separate particle, until today. Certainly in the LHC era the motivations for continued searches are clear and have been covered in many reviews. This review is focused on t…
▽ More
Charged lepton flavor violation (CLFV) is a clear signal of new physics; it directly addresses the physics of flavor and of generations. The search for CLFV has continued from the early 1940's, when the muon was identified as a separate particle, until today. Certainly in the LHC era the motivations for continued searches are clear and have been covered in many reviews. This review is focused on the experimental history with a view toward how these searches might progress. We examine of the status of searches for charged lepton flavor violation in the muon, tau, and other channels, and then examine the prospects for new efforts over the next decade. Finally, we examine what paths might be taken after the conclusion of upcoming experiments and what facilities might be required.
△ Less
Submitted 13 January, 2014; v1 submitted 22 July, 2013;
originally announced July 2013.
-
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber
Authors:
COUPP Collaboration,
E. Behnke,
T. Benjamin,
S. J. Brice,
D. Broemmelsiek,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
D. Fustin,
J. Hall,
C. Harnish,
I. Levine,
W. H. Lippincott,
T. Moan,
T. Nania,
R. Neilson,
E. Ramberg,
A. E. Robinson,
A. Sonnenschein,
E. Vázquez-Jáuregui,
R. A. Rivera,
L. Uplegger
Abstract:
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel…
▽ More
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.
△ Less
Submitted 31 January, 2014; v1 submitted 22 April, 2013;
originally announced April 2013.
-
First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site
Authors:
E. Behnke,
J. Behnke,
S. J. Brice,
D. Broemmelsiek,
J. I. Collar,
A. Conner,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
D. Fustin,
E. Grace,
J. Hall,
M. Hu,
I. Levine,
W. H. Lippincott,
T. Moan,
T. Nania,
E. Ramberg,
A. E. Robinson,
A. Sonnenschein,
M. Szydagis,
E. Vázquez-Jáuregui
Abstract:
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bub…
▽ More
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.
△ Less
Submitted 19 September, 2012; v1 submitted 13 April, 2012;
originally announced April 2012.
-
Measuring the masses of the charged hadrons using a RICH as a precision velocity spectrometer
Authors:
Peter S. Cooper,
Jurgen Engelfried
Abstract:
The Selex experiment measured several billion charged hadron tracks with a high precision magnetic momentum spectrometer and high precision RICH velocity spectrometer. We have analyzed these data to simultaneously measure the masses of all the long lived charged hadrons and anti-hadrons from the pi to the Omega using the same detector and technique. The statistical precision achievable with this d…
▽ More
The Selex experiment measured several billion charged hadron tracks with a high precision magnetic momentum spectrometer and high precision RICH velocity spectrometer. We have analyzed these data to simultaneously measure the masses of all the long lived charged hadrons and anti-hadrons from the pi to the Omega using the same detector and technique. The statistical precision achievable with this data sample is more than adequate for 0.1% mass measurements
We have used these measurements to develop and understand the systematic effects of a RICH as a precision velocity spectrometer with the goal of measuring 10 masses with precision ranging from 100 KeV for the lightest to 1000 KeV for the heaviest. This requires controlling the radius measurement of RICH rings to the ~10^{-4} level. Progress in the mass measurements and the required RICH analysis techniques developed are discussed.
△ Less
Submitted 9 September, 2010; v1 submitted 24 August, 2010;
originally announced August 2010.
-
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber
Authors:
E. Behnke,
J. Behnke,
S. J. Brice,
D. Broemmelsiek,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
D. Fustin,
J. Hall,
J. H. Hinnefeld,
M. Hu,
I. Levine,
E. Ramberg,
T. Shepherd,
A. Sonnenschein,
M. Szydagis
Abstract:
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during a…
▽ More
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg-day, consistent with a neutron background. This observation provides the strongest direct detection constraint to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$ GeV/c$^{2}$.
△ Less
Submitted 7 March, 2011; v1 submitted 20 August, 2010;
originally announced August 2010.
-
Renaissance of the ~1 TeV Fixed-Target Program
Authors:
T. Adams,
J. A. Appel,
K. E. Arms,
A. B. Balantekin,
J. M. Conrad,
P. S. Cooper,
Z. Djurcic,
W. Dunwoodie,
J. Engelfried,
P. H. Fisher,
E. Gottschalk,
A. de Gouvea,
K. Heller,
C. M. Ignarra,
G. Karagiorgi,
S. Kwan,
W. A. Loinaz,
B. Meadows,
R. Moore,
J. G. Morfín,
D. Naples,
P. Nienaber,
S. F. Pate,
V. Papavassiliou,
A. A. Petrov
, et al. (11 additional authors not shown)
Abstract:
This document describes the physics potential of a new fixed-target program based on a ~1 TeV proton source. Two proton sources are potentially available in the future: the existing Tevatron at Fermilab, which can provide 800 GeV protons for fixed-target physics, and a possible upgrade to the SPS at CERN, called SPS+, which would produce 1 TeV protons on target. In this paper we use an example T…
▽ More
This document describes the physics potential of a new fixed-target program based on a ~1 TeV proton source. Two proton sources are potentially available in the future: the existing Tevatron at Fermilab, which can provide 800 GeV protons for fixed-target physics, and a possible upgrade to the SPS at CERN, called SPS+, which would produce 1 TeV protons on target. In this paper we use an example Tevatron fixed-target program to illustrate the high discovery potential possible in the charm and neutrino sectors. We highlight examples which are either unique to the program or difficult to accomplish at other venues.
△ Less
Submitted 1 October, 2009; v1 submitted 18 May, 2009;
originally announced May 2009.
-
Study of the decay K+ => pi+,nu,nubar in the momentum region 140<Ppi<199 MeV/c
Authors:
E949 Collaboration,
A. V. Artamonov,
B. Bassalleck,
B. Bhuyan,
E. W. Blackmore,
D. A. Bryman,
S. Chen,
I-H. Chiang,
I. -A. Christidi,
P. S. Cooper,
M. V. Diwan,
J. S. Frank,
T. Fujiwara,
J. Hu,
J. Ives,
D. E. Jaffe,
S. Kabe,
S. H. Kettell,
M. M. Khabibullin,
A. N. Khotjantsev,
P. Kitching,
M. Kobayashi,
T. K. Komatsubara,
A. Konaka,
A. P. Kozhevnikov
, et al. (38 additional authors not shown)
Abstract:
Experiment E949 at Brookhaven National Laboratory has observed three new events consistent with the decay K+ => pi+,nu,nubar in the pion momentum region 140 < P_pi < 199 MeV/c in an exposure of 1.71e12 stopped kaons with an estimated total background of 0.93+-0.17(stat.)+0.32-0.24(syst.) events. This brings the total number of observed K+ => pi+,nu,nubar events to seven. Combining this observati…
▽ More
Experiment E949 at Brookhaven National Laboratory has observed three new events consistent with the decay K+ => pi+,nu,nubar in the pion momentum region 140 < P_pi < 199 MeV/c in an exposure of 1.71e12 stopped kaons with an estimated total background of 0.93+-0.17(stat.)+0.32-0.24(syst.) events. This brings the total number of observed K+ => pi+,nu,nubar events to seven. Combining this observation with previous results, assuming the pion spectrum predicted by the standard model, results in a branching ratio of (1.73+1.15-1.05)e-10. An interpretation of the results for alternative models of the decay K^ => pi+,nothing is also presented.
△ Less
Submitted 27 February, 2009;
originally announced March 2009.
-
Improved Spin-Dependent WIMP Limits from a Bubble Chamber
Authors:
E. Behnke,
J. I. Collar,
P. S. Cooper,
K. Crum,
M. Crisler,
M. Hu,
I. Levine,
D. Nakazawa,
H. Nguyen,
B. Odom,
E. Ramberg,
J. Rasmussen,
N. Riley,
A. Sonnenschein,
M. Szydagis,
R. Tschirhart
Abstract:
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly…
▽ More
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%. This illustrates the ability to employ bubble chambers in a new realm, the search for dark matter particles. Improved limits on the spin-dependent WIMP-proton scattering cross section are extracted from this first period. An extreme intrinsic insensitivity to the backgrounds commonly limiting these experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$) has been measured in operating conditions leading to the detection of low-energy nuclear recoils such as those expected from WIMPs.
△ Less
Submitted 17 April, 2008;
originally announced April 2008.
-
Physics at a Fermilab Proton Driver
Authors:
M. G. Albrow,
S. Antusch,
K. S. Babu,
T. Barnes,
A. O. Bazarko,
R. H. Bernstein,
T. J. Bowles,
S. J. Brice,
A. Ceccucci,
F. Cei,
H. W. KCheung,
D. C. Christian,
J. I. Collar,
J. Cooper,
P. S. Cooper,
A. Curioni,
A. deGouvea,
F. DeJongh,
P. F. Derwent,
M. V. Diwan,
B. A. Dobrescu,
G. J. Feldman,
D. A. Finley,
B. T. Fleming,
S. Geer
, et al. (23 additional authors not shown)
Abstract:
This report documents the physics case for building a 2 MW, 8 GeV superconducting linac proton driver at Fermilab.
This report documents the physics case for building a 2 MW, 8 GeV superconducting linac proton driver at Fermilab.
△ Less
Submitted 15 September, 2005;
originally announced September 2005.
-
First Observation of a New Narrow D_sJ Meson at 2632MeV/c^2
Authors:
Peter S. Cooper
Abstract:
We report the first observation of a charm-strange meson D_sJ(2632) at a mass of 2632.5+/-1.7 MeV/c^2 in data from SELEX, the charm hadro-production experiment E781 at Fermilab. This state is seen in two decay modes, D_s eta and D^0 K^+. In the D_s eta decay mode we observe a peak with 101 events over a combinatoric background of 54.9 events at a mass of 2635.4+/-3.3 MeV/c^2. There is a correspo…
▽ More
We report the first observation of a charm-strange meson D_sJ(2632) at a mass of 2632.5+/-1.7 MeV/c^2 in data from SELEX, the charm hadro-production experiment E781 at Fermilab. This state is seen in two decay modes, D_s eta and D^0 K^+. In the D_s eta decay mode we observe a peak with 101 events over a combinatoric background of 54.9 events at a mass of 2635.4+/-3.3 MeV/c^2. There is a corresponding peak of 21 events over a background of 6.9 at 2631.5+/-2.0 MeV/c^2 in the decay mode D^0 K^+. The relative branching ratio Gamma(D^0 K^+)/Γ(D_s eta) is 0.14+/-0.06. The full version of this paper has been accepted for publication in PRL (hep-ex/0406045). Here I have reproduced only the mass difference signal plots for the D_s eta and D^0 K^+ decay modes.
△ Less
Submitted 2 November, 2004;
originally announced November 2004.
-
Two RICH Detectors as Velocity Spectrometers in the CKM Experiment
Authors:
J. Engelfried,
P. S. Cooper,
A. Morelos,
I. Torres
Abstract:
We present the design of two velocity spectrometers, to be used in the recently approved CKM experiment. CKM's main goal is the measurement of the branching ratio of K+ -> pi+ nu nu with a precision of 10%, via decays in flight of the K+. The design of both RICH detectors is based on the SELEX Phototube RICH. We will discuss the design and the expected performance, based on studies with SELEX da…
▽ More
We present the design of two velocity spectrometers, to be used in the recently approved CKM experiment. CKM's main goal is the measurement of the branching ratio of K+ -> pi+ nu nu with a precision of 10%, via decays in flight of the K+. The design of both RICH detectors is based on the SELEX Phototube RICH. We will discuss the design and the expected performance, based on studies with SELEX data and Monte Carlo Simulations.
△ Less
Submitted 11 September, 2002;
originally announced September 2002.
-
In Celebration of the Fixed Target Program with the Tevatron
Authors:
Jeffrey A. Appel,
Charles N. Brown,
Peter S. Cooper,
Herman B. White
Abstract:
This document is an abridgement of the commemorative book prepared on the occasion of the symposium "In Celebration of the Fixed Target Program with the Tevatron" held at Fermilab on June 2, 2000. The full text with graphics contains, in addition to the material here, a section for each experiment including a "plain text" description, lists of all physics publications, lists of all degree recipi…
▽ More
This document is an abridgement of the commemorative book prepared on the occasion of the symposium "In Celebration of the Fixed Target Program with the Tevatron" held at Fermilab on June 2, 2000. The full text with graphics contains, in addition to the material here, a section for each experiment including a "plain text" description, lists of all physics publications, lists of all degree recipients and a photo from the archives. The full text is available on the web at: http://conferences.fnal.gov/tevft/book/
△ Less
Submitted 30 August, 2000;
originally announced August 2000.
-
New Limit for the Family-Number Non-conserving Decay mu+ to e+_gamma
Authors:
MEGA Collaboration,
M. L. Brooks,
Y. K. Chen,
M. D. Cooper,
P. S. Cooper,
M. Dzemidzic,
A. Empl,
C. A. Gagliardi,
G. E. Hogan,
E. B. Hughes,
E. V. Hungerford,
C. C. H. Jui,
J. E. Knott,
D. D. Koetke,
M. A. Kroupa K. A. Lan,
R. Manweiler,
B. W. Mayes,
R. E. Mischke,
L. E. Piilonen,
T. D. S. Stanislaus,
K. M. Stantz,
J. J. Szymanski,
R. E. Tribble,
X. L. Tu,
L. A. Van Ausdeln
, et al. (3 additional authors not shown)
Abstract:
An experiment has been performed to search for the muon- and electron-number non-conserving decay mu+ to e+_gamma. The upper limit for the branching ratio to be GAMMA(mu+ to e+_gamma)/GAMMA(mu+ to e+_nu_nubar) < 1.2e-11 with 90% confidence.
An experiment has been performed to search for the muon- and electron-number non-conserving decay mu+ to e+_gamma. The upper limit for the branching ratio to be GAMMA(mu+ to e+_gamma)/GAMMA(mu+ to e+_nu_nubar) < 1.2e-11 with 90% confidence.
△ Less
Submitted 7 May, 1999;
originally announced May 1999.
-
Kaon Radiative Decay K+ -> mu+ nu gamma at CKM at the Fermilab Main Injector
Authors:
C. Milstene,
P. S. Cooper,
M. A. Moinester
Abstract:
High statistics data for the K+ -> mu+ nu gamma decay can allow the precision determination of the kaon structure dependent form factors and the kaon polarizability. This study is possible at the proposed FNAL CKM experiment.
CKM (Charged Kaons at the Main injector) is a decay-in-flight spectrometer with two RICH, and designed to run at the main injector with a high kaon flux. The radiative de…
▽ More
High statistics data for the K+ -> mu+ nu gamma decay can allow the precision determination of the kaon structure dependent form factors and the kaon polarizability. This study is possible at the proposed FNAL CKM experiment.
CKM (Charged Kaons at the Main injector) is a decay-in-flight spectrometer with two RICH, and designed to run at the main injector with a high kaon flux. The radiative decay data will be taken complementary to the primary CKM effort to study the rare kaon decay (K to pi nu nubar) for which CKM was primarily designed. We summarize here the underlying physics of K ->mu nu gamma, the experimental status, and how the CKM spectrometer will be adapted for this study.
△ Less
Submitted 31 March, 1998;
originally announced March 1998.