Study of silicon photomultipliers for the readout of a lead/scintillating-fiber calorimeter
Authors:
F. Alemanno,
P. Bernardini,
A. Corvaglia,
G. De Matteis,
L. Martina,
A. Miccoli,
M. Panareo,
M. P. Panetta,
C. Pinto,
A. Surdo
Abstract:
The KLOE electromagnetic calorimeter is expected to be reused in the Near Detector complex of the DUNE experiment at Fermilab. The possible substitution of traditional Photomultiplier Tubes (PMTs) with Silicon Photomultipliers (SiPMs) in the refurbished calorimeter is the object of this investigation. A block of the KLOE lead-scintillating fiber calorimeter has been equipped with light guides and…
▽ More
The KLOE electromagnetic calorimeter is expected to be reused in the Near Detector complex of the DUNE experiment at Fermilab. The possible substitution of traditional Photomultiplier Tubes (PMTs) with Silicon Photomultipliers (SiPMs) in the refurbished calorimeter is the object of this investigation. A block of the KLOE lead-scintillating fiber calorimeter has been equipped with light guides and external trigger scintillators. The signals induced by cosmic rays and environmental radioactivity have been collected by SiPM arrays on one side of the calorimeter, and by conventional PMTs on the opposite side. Efficiency, stability, and timing resolution of SiPMs have been studied and compared with KLOE-PMTs performance. Conclusions about the convenience of substituting PMTs with SiPMs are drawn.
△ Less
Submitted 18 June, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Coded masks for imaging of neutrino events
Authors:
M. Andreotti,
P. Bernardini,
A. Bersani,
S. Bertolucci,
S. Biagi,
A. Branca,
C. Brizzolari,
G. Brunetti,
I. Cagnoli,
R. Calabrese,
A. Caminata,
A. Campani,
P. Carniti,
R. Cataldo,
C. Cattadori,
S. Cherubini,
V. Cicero,
M. Citterio,
S. Copello,
P. Cova,
E. Cristaldo Morales,
S. Davini,
N. Delmonte,
G. De Matteis,
S. Di Domizio
, et al. (54 additional authors not shown)
Abstract:
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-phot…
▽ More
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-photon detectors. In this respect, the proposed system is able to detect tracks over focal distances of about tens of centimeters. From numerical simulations it emerges that it is possible to successfully decode and recognize signals, even complex, with a relatively limited number of acquisition channels. Such innovative technique can be very fruitful in a new generation of detectors devoted to neutrino physics and dark matter search. Indeed the introduction of coded masks combined with SiPM detectors is proposed for a liquid-Argon target in the Near Detector of the DUNE experiment.
△ Less
Submitted 21 November, 2021; v1 submitted 22 May, 2021;
originally announced May 2021.