-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data
Authors:
The DEAP Collaboration,
P. Adhikari,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
D. J. Auty,
M. Batygov,
B. Beltran,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
J. F. Bueno,
B. Cai,
M. Cárdenas-Montes,
S. Choudhary,
B. T. Cleveland,
R. Crampton,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
G. Dolganov,
L. Doria,
F. A. Duncan,
M. Dunford,
E. Ellingwood
, et al. (73 additional authors not shown)
Abstract:
The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace…
▽ More
The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Electron-beam Calibration of Aerogel Tiles for the HELIX RICH Detector
Authors:
P. Allison,
M. Baiocchi,
J. J. Beatty,
L. Beaufore,
D. H. Calderone,
Y. Chen,
S. Coutu,
E. Ellingwood,
N. Green,
D. Hanna,
H. B. Jeon,
R. Mbarek,
K. McBride,
I. Mognet,
J. Musser,
S. Nutter,
S. O'Brien,
N. Park,
T. Rosin,
M. Tabata,
G. Tarlé,
G. Visser,
S. P. Wakely,
M. Yu
Abstract:
The HELIX cosmic-ray detector is a balloon-borne instrument designed to measure the flux of light isotopes in the energy range from 0.2 GeV/n to beyond 3 GeV/n. It will rely on a ring-imaging Cherenkov (RICH) detector for particle identification at energies greater than 1 GeV/n and will use aerogel tiles with refractive index near 1.15 as the radiator. To achieve the performance goals of the exper…
▽ More
The HELIX cosmic-ray detector is a balloon-borne instrument designed to measure the flux of light isotopes in the energy range from 0.2 GeV/n to beyond 3 GeV/n. It will rely on a ring-imaging Cherenkov (RICH) detector for particle identification at energies greater than 1 GeV/n and will use aerogel tiles with refractive index near 1.15 as the radiator. To achieve the performance goals of the experiment it is necessary to know the refractive index and its position dependence over the lateral extent of the tiles to a precision of O(10$^{-4}). In this paper we describe the apparatus and methods developed to calibrate the HELIX tiles in an electron beam, in order to meet this requirement.
△ Less
Submitted 18 July, 2023;
originally announced July 2023.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
D. J. Auty,
H. Benmansour,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
L. Doria,
M. Dunford,
E. Ellingwood,
A. Erlandson,
S. S. Farahani,
N. Fatemighomi,
G. Fiorillo
, et al. (72 additional authors not shown)
Abstract:
Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scat…
▽ More
Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.
△ Less
Submitted 5 January, 2022; v1 submitted 20 August, 2021;
originally announced August 2021.