-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (115 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley,
H. Coombes
, et al. (108 additional authors not shown)
Abstract:
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nuc…
▽ More
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 17 February, 2023;
originally announced February 2023.
-
Effective Field Theory Analysis of CDMSlite Run 2 Data
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (105 additional authors not shown)
Abstract:
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected back…
▽ More
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
Large-mass, low-threshold sapphire detector for rare event searches
Authors:
S. Verma,
S. Maludze,
M. Lee,
M. Chaudhuri,
V. Iyer,
V. K. S. Kashyap,
A. Kubik,
T. Lin,
R. Mahapatra,
N. Mirabolfathi,
N. Mishra,
B. Mohanty,
H. Neog,
A. Jastram,
M. Platt Platta
Abstract:
Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the first-of-its-kind 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm. The detector is designed to be sensitive for low-energy rare…
▽ More
Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the first-of-its-kind 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm. The detector is designed to be sensitive for low-energy rare interactions with an intention to investigate the low mass region of dark matter phase-space and search for CENNS at the reactor site. Sapphire is a crystal of aluminum oxide (Al2O3) and has been found to be a good candidate for light mass spin-dependent dark matter search experiments due to its lower atomic mass compared to other detector materials such as germanium and silicon. Using the data collected from the test facility at Texas A&M University, we were able to resolve low energy lines from calibration sources and estimated that our newly developed sapphire detector has a baseline recoil energy resolution of 18 eV. These detectors are operated at 0 V with the phonon-assisted detection providing a quenching-free low-threshold operation.
△ Less
Submitted 26 March, 2022;
originally announced March 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
SuperCDMS Collaboration,
Musaab Al-Bakry,
Imran Alkhatib,
Dorian Praia do Amaral,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Iman Ataee Langroudy,
Elham Azadbakht,
Samir Banik,
Corey Bathurst,
Dan Bauer,
Lucas Bezerra,
Rik Bhattacharyya,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Robert Cameron,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Mouli Chaudhuri,
Ran Chen,
Nicholas Chott
, et al. (106 additional authors not shown)
Abstract:
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucle…
▽ More
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 19 May, 2022; v1 submitted 4 March, 2022;
originally announced March 2022.
-
A novel active veto prototype detector with an inner target for improved rare event searches
Authors:
M. Chaudhuri,
A. Jastram,
G. Agnolet,
S. Banik,
H. Chen,
V. Iyer,
V. K. S. Kashyap,
A. Kubik,
M. Lee,
R. Mahapatra,
S. Maludze,
N. Mirabolfathi,
N. Mishra,
B. Mohanty,
H. Neog,
M. Platt
Abstract:
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detecto…
▽ More
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detector of mass $\sim$10 g was mounted inside the veto detector. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominantly gamma interactions) could be reduced by $>$ 90$\%$, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. During testing at the experimental site the veto detector prototype achieved a baseline resolution of 1.24 $\pm$ 0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147 $\pm$ 2 eV. The detectors were operated at mK temperatures. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.
△ Less
Submitted 22 February, 2022;
originally announced February 2022.
-
Pathfinder for a High Statistics Search for Missing Energy In Gamma Cascades
Authors:
James B. Dent,
Bhaskar Dutta,
Andrew Jastram,
Doojin Kim,
Andrew Kubik,
Rupak Mahapatra,
Surjeet Rajendran,
Harikrishnan Ramani,
Adrian Thompson,
Shubham Verma
Abstract:
We investigate the feasibility of a high statistics experiment to search for invisible decay modes in nuclear gamma cascades using 200 kg of %36 Cs(Tl) scintillators that are presently available at Texas A\&M. The experiment aims to search for missing energy by robustly establishing the absence of a photon in a well identified gamma cascade. We report on the experimental demonstration of the energ…
▽ More
We investigate the feasibility of a high statistics experiment to search for invisible decay modes in nuclear gamma cascades using 200 kg of %36 Cs(Tl) scintillators that are presently available at Texas A\&M. The experiment aims to search for missing energy by robustly establishing the absence of a photon in a well identified gamma cascade. We report on the experimental demonstration of the energy resolution necessary for this search. Prior explorations of this detector concept focused on baryonically coupled physics that could be emitted in $E_2$ transitions. We point out that this protocol can also search for particles that are coupled to photons by searching for the conversion of a photon produced in a gamma cascade into a hidden particle. Examples of these processes include the oscillation of a photon into a hidden photon and the conversion of a photon into an axion-like-particle either in the presence of a magnetic field or via the Primakoff process. This proof-of-concept apparatus appears to have the ability to search for hitherto unconstrained baryonically coupled scalars and pseudoscalars produced in $E_0$ and $M_0$ transitions. If successfully implemented, this experiment serves as a pathfinder for a larger detector with greater containment that can thoroughly probe the existence of new particles with mass below 4 MeV that lie in the poorly constrained supernova ``trapping window'' that exists between 100 keV and 30 MeV.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Large-mass single-electron-resolution detector for dark matter and neutrino elastic interaction searches
Authors:
V. Iyer,
N. Mirabolfathi,
G. Agnolet,
H. Chen,
A. Jastram,
F. Kadribasic,
V. K. S. Kashyap,
A. Kubik,
M. Lee,
R. Mahapatra,
B. Mohanty,
H. Neog,
M. Platt
Abstract:
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the or…
▽ More
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the order of $10^{-16}$ A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CE$ν$NS like searches.
△ Less
Submitted 3 August, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Phonon-mediated High-voltage Detector with Background Rejection for Low-mass Dark Matter and Reactor Coherent Neutrino Scattering Experiments
Authors:
H. Neog,
R. Mahapatra,
N. Mirabolfathi,
M. Platt,
A. Jastram,
G. Agnolet,
A. Kubik,
H. Chen,
B. Mohanty
Abstract:
We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of…
▽ More
We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. This new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.
△ Less
Submitted 23 June, 2020;
originally announced June 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
Authors:
SuperCDMS Collaboration,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
H. Coombes,
J. Corbett
, et al. (82 additional authors not shown)
Abstract:
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 5…
▽ More
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.
△ Less
Submitted 18 January, 2021; v1 submitted 26 November, 2019;
originally announced November 2019.
-
White Paper on New Opportunities at the Next-Generation Neutrino Experiments (Part 1: BSM Neutrino Physics and Dark Matter)
Authors:
C. A. Argüelles,
A. J. Aurisano,
B. Batell,
J. Berger,
M. Bishai,
T. Boschi,
N. Byrnes,
A. Chatterjee,
A. Chodos,
T. Coan,
Y. Cui,
A. de Gouvêa,
P. B. Denton,
A. De Roeck,
W. Flanagan,
R. P. Gandrajula,
A. Hatzikoutelis,
M. Hostert,
B. Jones,
B. J. Kayser,
K. J. Kelly,
D. Kim,
J. Kopp,
A. Kubik,
K. Lang
, et al. (25 additional authors not shown)
Abstract:
With the advent of a new generation of neutrino experiments which leverage high-intensity neutrino beams for precision measurements, it is timely to explore physics topics beyond the standard neutrino-related physics. Given that the realm of beyond the standard model (BSM) physics has been mostly sought at high-energy regimes at colliders, such as the LHC at CERN, the exploration of BSM physics in…
▽ More
With the advent of a new generation of neutrino experiments which leverage high-intensity neutrino beams for precision measurements, it is timely to explore physics topics beyond the standard neutrino-related physics. Given that the realm of beyond the standard model (BSM) physics has been mostly sought at high-energy regimes at colliders, such as the LHC at CERN, the exploration of BSM physics in neutrino experiments will enable complementary measurements at the energy regimes that balance that of the LHC. This is in concert with new ideas for high-intensity beams for fixed target and beam-dump experiments world-wide, e.g., those at CERN. The combination of the high intensity proton beam facilities and massive detectors for precision neutrino oscillation parameter measurements and for CP violation phase measurements will help make BSM physics reachable even in low energy regimes in accelerator based experiments. Large mass detectors with highly precise tracking and energy measurements, excellent timing resolution, and low energy thresholds will enable searches for BSM phenomena from cosmogenic origin, as well. Therefore, it is conceivable that BSM topics in the next generation neutrino experiments could be the dominant physics topics in the foreseeable future, as the precision of the neutrino oscillation parameter and CPV measurements continues to improve. In this spirit, this white paper provides a review of the current landscape of BSM theory in neutrino experiments in two selected areas of the BSM topics - dark matter and neutrino related BSM - and summarizes the current results from existing neutrino experiments to set benchmarks for both theory and experiment. This paper then provides a review of upcoming neutrino experiments throughout the next 10 - 15 year time scale and their capabilities to set the foundation for potential reach in BSM physics in the two aforementioned themes.
△ Less
Submitted 18 October, 2019; v1 submitted 18 July, 2019;
originally announced July 2019.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (79 additional authors not shown)
Abstract:
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ (…
▽ More
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the strongest limits for WIMP--germanium-nucleus interactions for masses $>$12 GeV/$c^2$.
△ Less
Submitted 29 August, 2017;
originally announced August 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
Background Studies for the MINER Coherent Neutrino Scattering Reactor Experiment
Authors:
MINER Collaboration,
G. Agnolet,
W. Baker,
D. Barker,
R. Beck,
T. J. Carroll,
J. Cesar,
P. Cushman,
J. B. Dent,
S. De Rijck,
B. Dutta,
W. Flanagan,
M. Fritts,
Y. Gao,
H. R. Harris,
C. C. Hays,
V. Iyer,
A. Jastram,
F. Kadribasic,
A. Kennedy,
A. Kubik,
I. Ogawa,
K. Lang,
R. Mahapatra,
V. Mandic
, et al. (25 additional authors not shown)
Abstract:
The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering proce…
▽ More
The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering process and the proposed experimental proximity to the reactor, as many as 5 to 20 events/kg/day are expected. We discuss the status of preliminary measurements to characterize the main backgrounds for the proposed experiment. Both in situ measurements at the experimental site and simulations using the MCNP and GEANT4 codes are described. A strategy for monitoring backgrounds during data taking is briefly discussed.
△ Less
Submitted 7 September, 2016;
originally announced September 2016.
-
Sensitivity to oscillation with a sterile fourth generation neutrino from ultra-low threshold neutrino-nucleus coherent scattering
Authors:
Bhaskar Dutta,
Yu Gao,
Andrew Kubik,
Rupak Mahapatra,
Nader Mirabolfathi,
Louis E. Strigari,
Joel W. Walker
Abstract:
We discuss prospects for probing short-range sterile neutrino oscillation using neutrino-nucleus coherent scattering with ultra-low energy ($\sim 10$ eV - 100 eV) recoil threshold cryogenic Ge detectors. The analysis is performed in the context of a specific and contemporary reactor-based experimental proposal, developed in cooperation with the Nuclear Science Center at Texas A\&M University, and…
▽ More
We discuss prospects for probing short-range sterile neutrino oscillation using neutrino-nucleus coherent scattering with ultra-low energy ($\sim 10$ eV - 100 eV) recoil threshold cryogenic Ge detectors. The analysis is performed in the context of a specific and contemporary reactor-based experimental proposal, developed in cooperation with the Nuclear Science Center at Texas A\&M University, and references developing technology based upon economical and scalable detector arrays. The baseline of the experiment is substantially shorter than existing measurements, as near as about 2 meters from the reactor core, and is moreover variable, extending continuously up to a range of about 10 meters. This proximity and variety combine to provide extraordinary sensitivity to a wide spectrum of oscillation scales, while facilitating the tidy cancellation of leading systematic uncertainties in the reactor source and environment. With 100~eV sensitivity, for exposures on the order of 200 kg$\cdot$y, we project an estimated sensitivity to first/fourth neutrino oscillation with a mass gap $Δm^2 \sim 1 \, {\rm eV}^2$ at an amplitude $\sin^2 2θ\sim 10^{-1}$, or $Δm^2 \sim 0.2 \, {\rm eV}^2$ at unit amplitude. Larger exposures, around 5,000 kg$\cdot$y, together with 10 eV sensitivity are capable of probing more than an additional order of magnitude in amplitude.
△ Less
Submitted 23 October, 2016; v1 submitted 9 November, 2015;
originally announced November 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.