(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–10 of 10 results for author: Lehnert, K W

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2311.01930  [pdf, other

    hep-ex hep-ph quant-ph

    Quantum Sensors for High Energy Physics

    Authors: Aaron Chou, Kent Irwin, Reina H. Maruyama, Oliver K. Baker, Chelsea Bartram, Karl K. Berggren, Gustavo Cancelo, Daniel Carney, Clarence L. Chang, Hsiao-Mei Cho, Maurice Garcia-Sciveres, Peter W. Graham, Salman Habib, Roni Harnik, J. G. E. Harris, Scott A. Hertel, David B. Hume, Rakshya Khatiwada, Timothy L. Kovachy, Noah Kurinsky, Steve K. Lamoreaux, Konrad W. Lehnert, David R. Leibrandt, Dale Li, Ben Loer , et al. (17 additional authors not shown)

    Abstract: Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Sta… ▽ More

    Submitted 3 November, 2023; originally announced November 2023.

    Comments: 63 pages, 8 figures, Quantum Sensors for HEP workshop report, April 26-28, 2023

  2. arXiv:2301.09721  [pdf, other

    hep-ex physics.ins-det

    New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver

    Authors: HAYSTAC Collaboration, M. J. Jewell, A. F. Leder, K. M. Backes, Xiran Bai, K. van Bibber, B. M. Brubaker, S. B. Cahn, A. Droster, Maryam H. Esmat, Sumita Ghosh, Eleanor Graham, Gene C. Hilton, H. Jackson, Claire Laffan, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, R. H. Maruyama, D. A. Palken, N. M. Rapidis, E. P. Ruddy, M. Simanovskaia, Sukhman Singh , et al. (4 additional authors not shown)

    Abstract: A search for dark matter axions with masses $>10 μみゅーeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μみゅーeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr… ▽ More

    Submitted 26 January, 2023; v1 submitted 23 January, 2023; originally announced January 2023.

    Comments: 20 pages, 16 figures

  3. arXiv:2203.14923  [pdf, other

    hep-ex astro-ph.CO hep-ph physics.ins-det

    Axion Dark Matter

    Authors: C. B. Adams, N. Aggarwal, A. Agrawal, R. Balafendiev, C. Bartram, M. Baryakhtar, H. Bekker, P. Belov, K. K. Berggren, A. Berlin, C. Boutan, D. Bowring, D. Budker, A. Caldwell, P. Carenza, G. Carosi, R. Cervantes, S. S. Chakrabarty, S. Chaudhuri, T. Y. Chen, S. Cheong, A. Chou, R. T. Co, J. Conrad, D. Croon , et al. (130 additional authors not shown)

    Abstract: Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg… ▽ More

    Submitted 29 March, 2023; v1 submitted 28 March, 2022; originally announced March 2022.

    Comments: restore and expand author list

  4. A quantum-enhanced search for dark matter axions

    Authors: K. M. Backes, D. A. Palken, S. Al Kenany, B. M. Brubaker, S. B. Cahn, A. Droster, Gene C. Hilton, Sumita Ghosh, H. Jackson, S. K. Lamoreaux, A. F. Leder, K. W. Lehnert, S. M. Lewis, M. Malnou, R. H. Maruyama, N. M. Rapidis, M. Simanovskaia, Sukhman Singh, D. H. Speller, I. Urdinaran, Leila R. Vale, E. C. van Assendelft, K. van Bibber, H. Wang

    Abstract: In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we do… ▽ More

    Submitted 4 August, 2020; originally announced August 2020.

    Comments: 7 pages, 4 figures

  5. arXiv:2003.08510  [pdf, other

    astro-ph.IM hep-ex physics.data-an

    An improved analysis framework for axion dark matter searches

    Authors: D. A. Palken, B. M. Brubaker, M. Malnou, S. Al Kenany, K. M. Backes, S. B. Cahn, Y. V. Gurevich, S. K. Lamoreaux, S. M. Lewis, R. H. Maruyama, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, Sukhman Singh, D. H. Speller, I. Urdinaran, K. van Bibber, L. Zhong, K. W. Lehnert

    Abstract: In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f… ▽ More

    Submitted 28 July, 2020; v1 submitted 18 March, 2020; originally announced March 2020.

    Comments: 22 pages, 5 figures

    Journal ref: Phys. Rev. D 101, 123011 (2020)

  6. arXiv:1803.03690  [pdf, other

    hep-ex physics.ins-det

    Results from phase 1 of the HAYSTAC microwave cavity axion experiment

    Authors: L. Zhong, S. Al Kenany, K. M. Backes, B. M. Brubaker, S. B. Cahn, G. Carosi, Y. V. Gurevich, W. F. Kindel, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, R. H. Maruyama, D. A. Palken, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, D. H. Speller, I. Urdinaran, K. A. van Bibber

    Abstract: We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγがんまγがんま}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μみゅー\rm eV$. This doubles the range… ▽ More

    Submitted 9 March, 2018; originally announced March 2018.

    Journal ref: Phys. Rev. D 97, 092001 (2018)

  7. arXiv:1706.08388  [pdf, other

    astro-ph.IM hep-ex

    The HAYSTAC Axion Search Analysis Procedure

    Authors: B. M. Brubaker, L. Zhong, S. K. Lamoreaux, K. W. Lehnert, K. A. van Bibber

    Abstract: We describe in detail the analysis procedure used to derive the first limits from the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a microwave cavity search for cold dark matter (CDM) axions with masses above $20\ μみゅー\text{eV}$. We have introduced several significant innovations to the axion search analysis pioneered by the Axion Dark Matter eXperiment (ADMX), including optimal filtering of t… ▽ More

    Submitted 22 December, 2017; v1 submitted 26 June, 2017; originally announced June 2017.

    Comments: 33 pages, 10 figures; added changes made in review process

    Journal ref: Phys. Rev. D 96, 123008 (2017)

  8. arXiv:1610.02580  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex

    First results from a microwave cavity axion search at 24 micro-eV

    Authors: B. M. Brubaker, L. Zhong, Y. V. Gurevich, S. B. Cahn, S. K. Lamoreaux, M. Simanovskaia, J. R. Root, S. M. Lewis, S. Al Kenany, K. M. Backes, I. Urdinaran, N. M. Rapidis, T. M. Shokair, K. A. van Bibber, D. A. Palken, M. Malnou, W. F. Kindel, M. A. Anil, K. W. Lehnert, G. Carosi

    Abstract: We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μみゅー\text{eV}$. We exclude axion models with two-photon coupling $g_{aγがんまγがんま} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μみゅー\text{eV} < m_a < 24.0~μみゅー\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde… ▽ More

    Submitted 9 February, 2017; v1 submitted 8 October, 2016; originally announced October 2016.

    Comments: 5 pages, 3 figures, accepted for publication in PRL. v2: added changes made during the review process

    Journal ref: Phys. Rev. Lett. 118, 061302 (2017)

  9. arXiv:1405.3685  [pdf, other

    physics.ins-det hep-ex

    Future Directions in the Microwave Cavity Search for Dark Matter Axions

    Authors: T. M. Shokair, J. Root, K. A. Van Bibber, B. Brubaker, Y. V. Gurevich, S. B. Cahn, S. K. Lamoreaux, M. A. Anil, K. W. Lehnert, B. K. Mitchell, A. Reed, G. Carosi

    Abstract: The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrate… ▽ More

    Submitted 14 May, 2014; originally announced May 2014.

  10. arXiv:1306.3591  [pdf, ps, other

    physics.ins-det hep-ex quant-ph

    Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches

    Authors: S. K. Lamoreaux, K. A. van Bibber, K. W. Lehnert, G. Carosi

    Abstract: We show that at higher frequencies, and thus higher axion masses, single-photon detectors become competitive and ultimately favored, when compared to quantum-limited linear amplifiers, as the detector technology in microwave cavity experimental searches for galactic halo dark matter axions. The cross-over point in this comparison is of order 10 GHz ($\sim 40\ μみゅー$eV), not far above the frequencies o… ▽ More

    Submitted 3 August, 2013; v1 submitted 15 June, 2013; originally announced June 2013.

    Comments: 5 pages, 1 figure new version address comments received