-
Status of the production of GEM chambers for the CMS experiment at Large Hadron Collider
Authors:
L. Benussi,
S. Bianco,
R. Campagnola,
M. Caponero,
S. Colafranceschi,
S. Meola,
E. Paoletti,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
R. Tesauro
Abstract:
The High Luminosity LHC phase includes an upgrade to the muon stations for the CMS Experiment. CMS trigger and muon identification performance will be crucial, and it is, therefore, necessary to install new GEM stations to extend acceptance in the high-η region. An explanation of the quality control test and an update on the status of production will be provided.
The High Luminosity LHC phase includes an upgrade to the muon stations for the CMS Experiment. CMS trigger and muon identification performance will be crucial, and it is, therefore, necessary to install new GEM stations to extend acceptance in the high-η region. An explanation of the quality control test and an update on the status of production will be provided.
△ Less
Submitted 28 March, 2024;
originally announced April 2024.
-
Searching for an eco-friendly gas mixture for the ALICE Resistive Plate Chambers
Authors:
Luca Quaglia,
R. Cardarelli,
B. Liberti,
E. Pastori,
G. Proto,
G. Aielli,
P. Camarri,
A. Di Ciacco,
L. Di Stante,
R. Santonico,
G. Alberghi,
D. Boscherini,
A. Bruni,
L. Massa,
A. Polini,
M. Romano,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo M. Ferrini,
G. Saviano,
M. Abbrescia,
L. Congedo
, et al. (25 additional authors not shown)
Abstract:
The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2…
▽ More
The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2014. Even though research activities are excluded from these regulations, the phase-down will inevitably increase their price and CERN is also aiming to cut down on its emissions. For these reasons it is crucial to find a more eco-friendly gas mixture for RPCs by the time of the LHC long shutdown 3, foreseen in 2026. Since $C_{2}H_{2}F_{4}$ is the main contributor to the mixture GWP, an extensive R&D process has started to replace it with tetrafluoropropene ($C_{3}H_{2}F_{4}$), due to its chemical similarity with $C_{2}H_{2}F_{4}$ and its low GWP (around 7). Preliminary tests with cosmic rays have shown promising results in terms of detector performance. The next step is to study the long-term behavior of RPCs operated with these new gas mixtures (aging studies). Since this is a subject of interest for all (and not only) the LHC experiments, a collaboration, ECOgas@GIF++, was setup to carry out joint studies. Among others, a small ALICE-like RPC was installed at the Gamma Irradiation Facility at CERN, where they are exposed to a strong radiation field, coming from a 12.5 TBq $^{137}$Cs source, which allows one to simulate many years of operation in a relatively short time. The facility also provides a muon beam at specific times of the year, which can be used to study the detector performance (e.g. efficiency and cluster size) during and after irradiation.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
The CYGNO Experiment
Authors:
Fernando Domingues Amaro,
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Caponero,
Danilo Santos Cardoso,
Gianluca Cavoto,
André Cortez,
Igor Abritta Costa,
Rita Joanna da Cruz Roque,
Emiliano Dané,
Giorgio Dho,
Flaminia Di Giambattista,
Emanuele Di Marco,
Giovanni Grilli di Cortona,
Giulia D'Imperio,
Francesco Iacoangeli,
Herman Pessoa Lima Júnior,
Guilherme Sebastiao Pinheiro Lopes,
Amaro da Silva Lopes Júnior,
Giovanni Maccarrone,
Rui Daniel Passos Mano,
Michela Marafini,
Robert Renz Marcelo Gregorio
, et al. (25 additional authors not shown)
Abstract:
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its proper…
▽ More
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its properties. Gaseous time projection chambers (TPC) with optical readout are very promising detectors combining the detailed event information provided by the TPC technique with the high sensitivity and granularity of latest-generation scientific light sensors. The CYGNO experiment (a CYGNus module with Optical readout) aims to exploit the optical readout approach of multiple-GEM structures in large volume TPCs for the study of rare events as interactions of low-mass DM or solar neutrinos. The combined use of high-granularity sCMOS cameras and fast light sensors allows the reconstruction of the 3D direction of the tracks, offering good energy resolution and very high sensitivity in the few keV energy range, together with a very good particle identification useful for distinguishing nuclear recoils from electronic recoils. This experiment is part of the CYGNUS proto-collaboration, which aims at constructing a network of underground observatories for directional DM search. A one cubic meter demonstrator is expected to be built in 2022/23 aiming at a larger scale apparatus (30 m$^3$--100 m$^3$) at a later stage.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
Authors:
A. Samalan,
M. Tytgat,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. DaCosta,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal,
A. Cabrera
, et al. (86 additional authors not shown)
Abstract:
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen…
▽ More
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
△ Less
Submitted 2 November, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.
-
Identification of low energy nuclear recoils in a gas TPC with optical readout
Authors:
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Arturo Caponero,
Gianluca Cavoto,
Andre Cortez,
Igor Abritta Costa,
Emanuele Di Marco,
Giulia D'Imperio,
Giorgio Dho,
Fabrizio Iacoangeli,
Giovanni Maccarrone,
Michela Marafini,
Giovanni Mazzitelli,
Andrea Messina,
Rafael Antunes Nobrega,
Aldo Orlandi,
Emiliano Paoletti,
Luciano Passamonti,
Fabrizio Petrucci,
Davide Piccolo,
Daniele Pierluigi,
Davide Pinci,
Francesco Renga
, et al. (5 additional authors not shown)
Abstract:
The search for a novel technology able to detect and reconstruct nuclear recoil events in the keV energy range has become more and more important as long as vast regions of high mass WIMP-like Dark Matter candidate have been excluded. Gaseous Time Projection Chambers (TPC) with optical readout are very promising candidate combining the complete event information provided by the TPC technique to th…
▽ More
The search for a novel technology able to detect and reconstruct nuclear recoil events in the keV energy range has become more and more important as long as vast regions of high mass WIMP-like Dark Matter candidate have been excluded. Gaseous Time Projection Chambers (TPC) with optical readout are very promising candidate combining the complete event information provided by the TPC technique to the high sensitivity and granularity of last generation scientific light sensors. A TPC with an amplification at the anode obtained with Gas Electron Multipliers (GEM) was tested at the Laboratori Nazionali di Frascati. Photons and neutrons from radioactive sources were employed to induce recoiling nuclei and electrons with kinetic energy in the range [1-100] keV. A He-CF4 (60/40) gas mixture was used at atmospheric pressure and the light produced during the multiplication in the GEM channels was acquired by a high position resolution and low noise scientific CMOS camera and a photomultiplier. A multi-stage pattern recognition algorithm based on an advanced clustering technique is presented here. A number of cluster shape observables are used to identify nuclear recoils induced by neutrons originated from a AmBe source against X-ray 55Fe photo-electrons. An efficiency of 18% to detect nuclear recoils with an energy of about 6 keV is reached obtaining at the same time a 96% 55Fe photo-electrons suppression. This makes this optically readout gas TPC a very promising candidate for future investigations of ultra-rare events as directional direct Dark Matter searches.
△ Less
Submitted 27 October, 2021; v1 submitted 24 July, 2020;
originally announced July 2020.
-
A density-based clustering algorithm for the CYGNO data analysis
Authors:
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
G. Dho,
F. Iacoangeli,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
R. A. Nobrega,
A. Orlandi,
E. Paoletti,
L. Passamonti,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga
, et al. (4 additional authors not shown)
Abstract:
Time Projection Chambers (TPCs) working in combination with Gas Electron Multipliers (GEMs) produce a very sensitive detector capable of observing low energy events. This is achieved by capturing photons generated during the GEM electron multiplication process by means of a high-resolution camera. The CYGNO experiment has recently developed a TPC Triple GEM detector coupled to a low noise and high…
▽ More
Time Projection Chambers (TPCs) working in combination with Gas Electron Multipliers (GEMs) produce a very sensitive detector capable of observing low energy events. This is achieved by capturing photons generated during the GEM electron multiplication process by means of a high-resolution camera. The CYGNO experiment has recently developed a TPC Triple GEM detector coupled to a low noise and high spatial resolution CMOS sensor. For the image analysis, an algorithm based on an adapted version of the well-known DBSCAN was implemented, called iDBSCAN. In this paper a description of the iDBSCAN algorithm is given, including test and validation of its parameters, and a comparison with DBSCAN itself and a widely used algorithm known as Nearest Neighbor Clustering (NNC). The results show that the adapted version of DBSCAN is capable of providing full signal detection efficiency and very good energy resolution while improving the detector background rejection.
△ Less
Submitted 28 September, 2020; v1 submitted 3 July, 2020;
originally announced July 2020.
-
Stability and detection performance of a GEM-based Optical Readout TPC with He/CF$_4$ gas mixtures
Authors:
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
G. Dho,
F. Iacoangeli,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
R. A. Nobrega,
A. Orlandi,
E. Paoletti,
L. Passamonti,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga
, et al. (4 additional authors not shown)
Abstract:
The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost…
▽ More
The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost full detection efficiency in the whole detector volume was found with both mixtures, while a light yield about 20\% larger for the 60/40 was found. The electrostatic stability was tested by monitoring voltages and currents during 25 days. The detector worked in very stable and safe condition for the whole period. In the presence of less CF$_4$, a larger probability of unstable events was clearly detected.
△ Less
Submitted 17 August, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
CMS RPC Background -- Studies and Measurements
Authors:
R. Hadjiiska,
A. Samalan,
M. Tytgat,
N. Zaganidis,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. Da Costa,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal
, et al. (84 additional authors not shown)
Abstract:
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd…
▽ More
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.
△ Less
Submitted 13 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
First evidence of luminescence in a He/CF$_4$ gas mixture induced by non-ionizing electrons
Authors:
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
G. Dho,
F. Iacoangeli,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
A. Orlandi,
E. Paoletti,
L. Passamonti,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga,
F. Rosatelli
, et al. (3 additional authors not shown)
Abstract:
Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being developed for low-energy and rare event studies, such as Dark Matter search. So far, the optical approach exploits the light produced during the avalanche proc…
▽ More
Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being developed for low-energy and rare event studies, such as Dark Matter search. So far, the optical approach exploits the light produced during the avalanche processes in GEM channels. Further luminescence in the gas can be induced by electrons accelerated by a suitable electric field. The CYGNO collaboration studied this process with a combined use of a triple-GEM structure and a grid in an He/CF$_4$ (60/40) gas mixture at atmospheric pressure. Results reported in this paper allow to conclude that with an electric field of about 11~kV/cm a photon production mean free path of about 1.0~cm was found.
△ Less
Submitted 2 July, 2020; v1 submitted 22 April, 2020;
originally announced April 2020.
-
A 1 m$^3$ Gas Time Projection Chamber with Optical Readout for Directional Dark Matter Searches: the CYGNO Experiment
Authors:
E. Baracchini,
R. Bedogni,
F. Bellini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
F. Iacoangeli,
G. Maccarone,
M. Marafini,
G. Mazzitelli,
A. Messina,
A. Orlandi,
E. Paoletti,
L. Passamonti,
A. Pelosi,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga
, et al. (3 additional authors not shown)
Abstract:
The aim of the CYGNO project is the construction and operation of a 1~m$^3$ gas TPC for directional dark matter searches and coherent neutrino scattering measurements, as a prototype toward the 100-1000~m$^3$ (0.15-1.5 tons) CYGNUS network of underground experiments. In such a TPC, electrons produced by dark-matter- or neutrino-induced nuclear recoils will drift toward and will be multiplied by a…
▽ More
The aim of the CYGNO project is the construction and operation of a 1~m$^3$ gas TPC for directional dark matter searches and coherent neutrino scattering measurements, as a prototype toward the 100-1000~m$^3$ (0.15-1.5 tons) CYGNUS network of underground experiments. In such a TPC, electrons produced by dark-matter- or neutrino-induced nuclear recoils will drift toward and will be multiplied by a three-layer GEM structure, and the light produced in the avalanche processes will be readout by a sCMOS camera, providing a 2D image of the event with a resolution of a few hundred micrometers. Photomultipliers will also provide a simultaneous fast readout of the time profile of the light production, giving information about the third coordinate and hence allowing a 3D reconstruction of the event, from which the direction of the nuclear recoil and consequently the direction of the incoming particle can be inferred. Such a detailed reconstruction of the event topology will also allow a pure and efficient signal to background discrimination. These two features are the key to reach and overcome the solar neutrino background that will ultimately limit non-directional dark matter searches.
△ Less
Submitted 8 January, 2020;
originally announced January 2020.
-
Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment
Authors:
M. Abbrescia,
P. Van Auwegem,
L. Benussi,
S. Bianco,
S. Cauwenbergh,
M. Ferrini,
S. Muhammad,
L. Passamonti,
D. Pierluigi,
D. Piccolo,
F. Primavera,
A. Russo,
G. Saviano,
M. Tytgat
Abstract:
The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of ef…
▽ More
The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO2 and CF3I based gas mixtures are presented and discussed for the possible application in the CMS experiment.
△ Less
Submitted 26 May, 2016;
originally announced May 2016.
-
Eco-friendly gas mixtures for Resistive Plate Chambers based on Tetrafluoropropene and Helium
Authors:
M. Abbrescia,
L. Benussi,
S. Bianco,
M. Ferrini,
S. Muhammad,
L. Passamonti,
D. Pierluigi,
D. Piccolo,
F. Primavera,
A. Russo,
G. Saviano
Abstract:
Due to the recent restrictions deriving from the application of the Kyoto protocol, the main components of the gas mixtures presently used in the Resistive Plate Chambers systems of the LHC experiments will be most probably phased out of production in the coming years. Identifying possible replacements with the adequate characteristics requires an intense R&D, which was recently started, also in c…
▽ More
Due to the recent restrictions deriving from the application of the Kyoto protocol, the main components of the gas mixtures presently used in the Resistive Plate Chambers systems of the LHC experiments will be most probably phased out of production in the coming years. Identifying possible replacements with the adequate characteristics requires an intense R&D, which was recently started, also in collaborations across the various experiments. Possible candidates have been proposed and are thoroughly investigated. Some tests on one of the most promising candidate - HFO-1234ze, an allotropic form of tetrafluoropropane- have already been reported. Here an innovative approach, based on the use of Helium, to solve the problems related to the too elevate operating voltage of HFO-1234ze based gas mixtures, is discussed and the relative first results are shown.
△ Less
Submitted 4 May, 2016;
originally announced May 2016.
-
A study of HFO-1234ze (1,3,3,3-Tetrafluoropropene) as an eco-friendly replacement in RPC detectors
Authors:
L. Benussi,
S. Bianco,
M. Ferrini,
L. Passamonti,
D. Pierluigi,
D. Piccolo,
A. Russo,
G. Saviano
Abstract:
The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned.
This report shows results of studies on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze.
The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned.
This report shows results of studies on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Study of gas contaminants and interaction with materials in RPC closed loop system
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminan…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 22 March, 2013; v1 submitted 21 February, 2013;
originally announced February 2013.
-
A study of gas contaminants and interaction with materials in RPC closed loop systems
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contami…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 5 October, 2012;
originally announced October 2012.
-
Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning
Authors:
S. Colafranceschi,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
A. Aleksandrov,
U. Berzano,
C. Calabria,
C. Carrillo,
A. Colaleo,
V. Genchev,
P. Iaydjiev,
M. Kang,
K. S. Lee,
F. Loddo,
S. K. Park,
G. Pugliese,
M. Maggi,
S. Shin,
M. Rodozov
, et al. (3 additional authors not shown)
Abstract:
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep…
▽ More
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep the GGM response insensitive to environmental temperature and atmospheric pressure variations. Recent results are presented on the feedback method used and on alternative algorithms.
△ Less
Submitted 18 September, 2012;
originally announced September 2012.
-
Study of gas purifiers for the CMS RPC detector
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. L. Fabbri,
F. Felli,
M. Ferrini,
M. Giardoni,
T. Greci,
A. Paolozzi,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
S. Buontempo,
A. Cimmino,
M. de Gruttola,
F Fabozzi d A. O. M. Iorio,
L. Lista,
P. Paolucci,
P. Baesso,
G. Belli,
D. Pagano,
S. P. Ratti,
A. Vicini
, et al. (4 additional authors not shown)
Abstract:
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clar…
▽ More
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.
△ Less
Submitted 26 December, 2010;
originally announced December 2010.
-
A new approach in modeling the response of RPC detectors
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. L. Fabbri,
M. Giardoni,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
S. Buontempo,
A. Cimmino,
M. de Gruttola,
F Fabozzi,
A. O. M. Iorio,
L. Lista,
P. Paolucci,
P. Baesso,
G. Belli,
D. Pagano,
S. P. Ratti,
A. Vicini,
P. Vitulo,
C. Viviani,
A. Sharma
, et al. (1 additional authors not shown)
Abstract:
The response of RPC detectors is highly sensitive to environmental variables. A novel approach is presented to model the response of RPC detectors in a variety of experimental conditions. The algorithm, based on Artificial Neural Networks, has been developed and tested on the CMS RPC gas gain monitoring system during commissioning.
The response of RPC detectors is highly sensitive to environmental variables. A novel approach is presented to model the response of RPC detectors in a variety of experimental conditions. The algorithm, based on Artificial Neural Networks, has been developed and tested on the CMS RPC gas gain monitoring system during commissioning.
△ Less
Submitted 26 December, 2010;
originally announced December 2010.
-
Construction of the first full-size GEM-based prototype for the CMS high-$η$ muon system
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. Van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. Fabbri,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
A. Marinov,
M. Tytgat,
N. Zaganidis
, et al. (10 additional authors not shown)
Abstract:
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the…
▽ More
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the design and construction of a full-size prototype for the CMS endcap system, the largest Triple-GEM detector built to-date. We present details on the 3D modeling of the detector geometry, the implementation of the readout strips and electronics, and the detector assembly procedure.
△ Less
Submitted 9 December, 2010; v1 submitted 7 December, 2010;
originally announced December 2010.
-
The upgraded Outer em calorimeter of FOCUS at Fermilab
Authors:
S. Bianco,
F. L. Fabbri,
M. Giardoni,
L. Passamonti,
V. Russo,
S. Sarwar,
A. Zallo,
S. Carrillo,
H. Mendez,
G. Gianini,
J. Anjos,
I. Bediaga,
C. Gobel,
A. Laudo,
J. Magnin,
J. Miranda,
I. Pepe,
F. Simao,
A. Sanchez,
A. Reis
Abstract:
Operational performance, algorithms, stability and physics results of the
Outer em calorimeter of FOCUS are overviewed.
Operational performance, algorithms, stability and physics results of the
Outer em calorimeter of FOCUS are overviewed.
△ Less
Submitted 30 December, 1999;
originally announced December 1999.