-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Alignment of the CLAS12 central hybrid tracker with a Kalman Filter
Authors:
S. J. Paul,
A. Peck,
M. Arratia,
Y. Gotra,
V. Ziegler,
R. De Vita,
F. Bossu,
M. Defurne,
H. Atac,
C. Ayerbe Gayoso,
L. Baashen,
N. A. Baltzell,
L. Barion,
M. Bashkanov,
M. Battaglieri,
I. Bedlinskiy,
B. Benkel,
F. Benmokhtar,
A. Bianconi,
L. Biondo,
A. S. Biselli,
M. Bondi,
S. Boiarinov,
K. Th. Brinkmann,
W. J. Briscoe
, et al. (109 additional authors not shown)
Abstract:
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors wit…
▽ More
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$μ$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
The Apollo ATCA Design for the CMS Track Finder and the Pixel Readout at the HL-LHC
Authors:
A. Albert,
Z. Demiragli,
D. Gastler,
K. Hahn,
E. Hazen,
P. Kotamnives,
S. Noorudhin,
A. Peck,
J. Rohlf,
C. Strohman,
P. Wittich,
R. Zou
Abstract:
The challenging conditions of the High-Luminosity LHC require tailored hardware designs for the trigger and data acquisition systems. The Apollo platform features a "Service Module" with a powerful system-on-module computer that provides standard ATCA communications and application-specific "Command Module"s with large FPGAs and high-speed optical fiber links. The CMS version of Apollo will be use…
▽ More
The challenging conditions of the High-Luminosity LHC require tailored hardware designs for the trigger and data acquisition systems. The Apollo platform features a "Service Module" with a powerful system-on-module computer that provides standard ATCA communications and application-specific "Command Module"s with large FPGAs and high-speed optical fiber links. The CMS version of Apollo will be used for the track finder and the pixel readout. It features up to two large FPGAs and more than 100 optical links with speeds up to 25\,Gb/s. We study carefully the design and performance of the board by using customized firmware to test power consumption, heat dissipation, and optical link integrity. This paper presents the results of these performance tests, design updates, and future plans.
△ Less
Submitted 3 February, 2022; v1 submitted 29 November, 2021;
originally announced December 2021.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.