(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–6 of 6 results for author: Peterson, D A

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2103.04755  [pdf, other

    physics.ins-det hep-ex

    The Design, Construction, and Commissioning of the KATRIN Experiment

    Authors: M. Aker, K. Altenmüller, J. F. Amsbaugh, M. Arenz, M. Babutzka, J. Bast, S. Bauer, H. Bechtler, M. Beck, A. Beglarian, J. Behrens, B. Bender, R. Berendes, A. Berlev, U. Besserer, C. Bettin, B. Bieringer, K. Blaum, F. Block, S. Bobien, J. Bohn, K. Bokeloh, H. Bolz, B. Bornschein, L. Bornschein , et al. (204 additional authors not shown)

    Abstract: The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa… ▽ More

    Submitted 11 June, 2021; v1 submitted 5 March, 2021; originally announced March 2021.

    Comments: Added missing acknowledgement, corrected performance statement in chapter 4.2.5, updated author list and references

  2. arXiv:1905.04407  [pdf, other

    physics.ins-det hep-ex

    Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data

    Authors: K. S. Khaw, M. Bartolini, H. Binney, R. Bjorkquist, A. Chapelain, A. Driutti, C. Ferrari, A. T. Fienberg, A. Fioretti, C. Gabbanini, S. Ganguly, L. K. Gibbons, A. Gioiosa, K. Giovanetti, W. P. Gohn, T. P. Gorringe, J. B. Hempstead, D. W. Hertzog, M. Iacovacci, J. Kaspar, A. Kuchibhotla, S. Leo, A. Lusiani, S. Mastroianni, G. Pauletta , et al. (9 additional authors not shown)

    Abstract: A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS dat… ▽ More

    Submitted 22 February, 2020; v1 submitted 10 May, 2019; originally announced May 2019.

    Comments: 16 pages, 27 figures. Updated to match published version

    Report number: FERMILAB-PUB-19-198-PPD

    Journal ref: NIM A 945, 162558 (2019)

  3. arXiv:1611.03180  [pdf, other

    physics.ins-det hep-ex

    Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications

    Authors: J. Kaspar, A. T. Fienberg, D. W. Hertzog, M. A. Huehn, P. Kammel, K. S. Khaw, D. A. Peterson, M. W. Smith, T. D. Van Wechel, A. Chapelain, L. K. Gibbons, D. A. Sweigart, C. Ferrari, A. Fioretti, C. Gabbanini, G. Venanzoni, M. Iacovacci, S. Mastroianni, K. Giovanetti, W. Gohn, T. Gorringe, D. Pocanic

    Abstract: We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storag… ▽ More

    Submitted 22 December, 2016; v1 submitted 9 November, 2016; originally announced November 2016.

    Comments: In version 2, simplified schematics of the SiPM board was fixed, and high rate test redone

    Report number: FERMILAB-PUB-16-516-E-PPD

  4. arXiv:1412.5525  [pdf, other

    physics.ins-det hep-ex

    Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout

    Authors: A. T. Fienberg, L. P. Alonzi, A. Anastasi, R. Bjorkquist, D. Cauz, R. Fatemi, C. Ferrari, A. Fioretti, A. Frankenthal, C. Gabbanini, L. K. Gibbons, K. Giovanetti, S. D. Goadhouse, W. P. Gohn, T. P. Gorringe, D. W. Hertzog, M. Iacovacci, P. Kammel, J. Kaspar, B. Kiburg, L. Li, S. Mastroianni, G. Pauletta, D. A. Peterson, D. Pocanic , et al. (8 additional authors not shown)

    Abstract: The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes… ▽ More

    Submitted 19 February, 2015; v1 submitted 17 December, 2014; originally announced December 2014.

    Comments: 14 pages, 19 figures, accepted to Nucl.Instrum.Meth. A. In v2, edited Figures 14,15, and 17 for clarity, improved explanation of energy resolution systematics, added reference to SiPM

    Report number: FERMILAB-PUB-14-526-E-PPD

  5. arXiv:1404.2925  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Focal-plane detector system for the KATRIN experiment

    Authors: J. F. Amsbaugh, J. Barrett, A. Beglarian, T. Bergmann, H. Bichsel, L. I. Bodine, J. Bonn, N. M. Boyd, T. H. Burritt, Z. Chaoui, S. Chilingaryan, T. J. Corona, P. J. Doe, J. A. Dunmore, S. Enomoto, J. Fischer, J. A. Formaggio, F. M. Fränkle, D. Furse, H. Gemmeke, F. Glück, F. Harms, G. C. Harper, J. Hartmann, M. A. Howe , et al. (26 additional authors not shown)

    Abstract: The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electro… ▽ More

    Submitted 28 January, 2015; v1 submitted 10 April, 2014; originally announced April 2014.

    Comments: 28 pages. Two figures revised for clarity. Final version published in Nucl. Inst. Meth. A

    Journal ref: Nucl. Inst. Meth. A 778 (2015) 40-60

  6. arXiv:1310.1178  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Dead layer on silicon p-i-n diode charged-particle detectors

    Authors: B. L. Wall, J. F. Amsbaugh, A. Beglarian, T. Bergmann, H. C. Bichsel, L. I. Bodine, N. M. Boyd, T. H. Burritt, Z. Chaoui, T. J. Corona, P. J. Doe, S. Enomoto, F. Harms, G. C. Harper, M. A. Howe, E. L. Martin, D. S. Parno, D. A. Peterson, L. Petzold, P. Renschler, R. G. H. Robertson, J. Schwarz, M. Steidl, T. D. Van Wechel, B. A. VanDevender , et al. (3 additional authors not shown)

    Abstract: Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-… ▽ More

    Submitted 7 October, 2013; v1 submitted 4 October, 2013; originally announced October 2013.

    Comments: Manuscript submitted to NIM A

    Journal ref: NIM A 744 (2014), 73--79